• Title/Summary/Keyword: Liquid tube

Search Result 535, Processing Time 0.024 seconds

Heat Transfer and Fluid Flow Evaluation of Radiator for Computer Cooling (컴퓨터용 라디에이터의 열전달 및 유동특성 평가)

  • Cha, Dong-An;Kwon, Oh-Kyung;Yun, Jae-Ho;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1153-1158
    • /
    • 2009
  • The performance of louver-finned flat-tube and fin & tube radiators for computer CPU liquid cooling were experimentally investigated. In this study, 7 samples of radiators with different shape and pass number (1, 2, 10) were tested in a wind tunnel. The experiments were conducted under the different air velocity range from 1 to 4 m/s. The water flow rate through a pass was 1.2 LPM. Inlet temperatures of air and water were $20^{\circ}C$ and $30^{\circ}C$ respectively. It was found that the best performance was observed in the louver-finned flat-tube sample considering pressure drop and heat transfer coefficient.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant (대체냉매의 2중관 응축기 열 및 물질전달과 성능평가)

  • 이상무;박병덕;소산번
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

A Study on the Thermal Performance of Radiator for Computer CPU Cooling (컴퓨터 CPU 냉각용 라디에이터의 열성능에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Choi, Mi-Jin;Yun, Jae-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.258-263
    • /
    • 2007
  • The performance of louver-finned flat-tube radiators for computer CPU liquid cooling were experimentally investigated. In this study, 5 samples of louver-finned flat-tube radiators with different width size (19mm, 24mm), tube hole (1, 9) and pass number (1, 2, 5) were tested in a wind tunnel. The experiments were conducted under the different air velocity ranging from 1 to 5 m/s. The water flow rate through a pass was 1.7 LPM. Inlet temperatures of air and water were $20^{\circ}C$ and $30^{\circ}C$ respectively. The results showed that the best performance in the 24mm sample considering pressure drop and heat transfer coefficient.

  • PDF

Fundamental study on performance characteristics of a micro heat pipe with triangular cross section (삼각단면 극소히트파이프의 작동특성에 관한 기초 연구)

  • 문석환;김종오;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

Consolidation Analysis of Geotextile Tubes Filled with Highly Compressible Sludge Using Variable Coefficients of Consolidation

  • Kim, Hyeongjoo;Kim, Hyeongsoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.25-32
    • /
    • 2021
  • Geotextile tube technology has been perceived as an economical solution for liquid sludge treatment, and analyzing its consolidation behavior is necessary to be able to evaluate the dewatering capabilities of large geotextile tubes filled with contaminated soil, tailings, sewage sludge, and so on. The objectives of this study are to present a method that can adequately convey the consolidation behavior of geotextile tubes filled with sewage sludge, and to investigate the effects of various geotextile tube consolidation parameters. In this study, variable coefficients of consolidation are utilized to analyze the consolidation process of geotextile tubes filled with sewage sludge. The consolidation solution was verified by comparing the measured and predicted data from a hanging bag test conducted in the literature. After verifying the proposed solution, the consolidation parameters of a geotextile tube composed of a woven polypropylene outer layer and a non-woven polypropylene layer filled sewage sludge were obtained. Using the obtained parameters, the consolidation behavior of a large-scale composite geotextiles tube was predicted.

Flow Boiling Heat Transfer Characteristics of Liquid Nitrogen in Plain and Wire Coil Inserted Tubes (평활관 및 와이어코일을 삽입한 열전달촉진관에서 액체질소의 흐름비등열전달 특성)

  • Hwang Jee-Sang;Yun Rin;Kim Yongchan;Chung Jin Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.927-933
    • /
    • 2005
  • Boiling heat transfer characteristics of liquid nitrogen in a stainless steel plain tube and wire coil inserted tubes were investigated. The test tubes, which had an inner diameter of 10.6 m and a length of 1.65 m, were horizontally located. Five wire coils having different pitch and thickness were inserted into the plain tube. The pitches of the wire coils were 18.4, 27.6, and 36.8 m, and the thickness was 1.5, 2.0, and 2.5 mm respectively. Tests were conducted at a saturation temperature of $-191^{\circ}$, mass fluxes from 58 to 105 kg/$m^2s$, and heat fluxes from 22.5 to 32.7 kw/$m^2$. A direct heating method was used to apply heat to the test section. The boiling heat transfer coefficients of liquid nitrogen were represented as a function of vapor quality, which showed significant drop at the dryout vapor quality. The maximum heat transfer enhancement using the wire coil inserted tubes over the plain tube was $174\%$ for 'Wire 3' having a thickness of 2.5 mm and a pitch of 18.4 mm.

Atomization Effect of Supersonic Liquid Jet by a Nozzle L/d of Subscale High-Pressure Injection System (축소형 초고압 분사 시스템의 노즐 L/d에 따른 초음속 액체 제트의 미립화 특성)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.196-199
    • /
    • 2011
  • Subscale high-pressure injection system which use two-stage light gas gun composed with high-pressure tube, pump tube and launch tube can make supersonic liquid jet. The supersonic liquid jet enhances droplet atomization by shockwave in front of the jet. In this study, the experiments was executed to identify the atomization characteristics of the supersonic liquid jet using straight cone nozzle. SMD which presents the atomization characteristics was decreased from $151.2{\mu}m$ to $52.25{\mu}m$ by increasing of L/d.

  • PDF

The Effects of Tube Arrangement and Inclination on the Pressure Drop in Tube Bundles of Intermediate Beat Exchanger in Liquid Meta Reactor (액체금속로 중간열교환기 관다발에서의 튜브배열과 경사각도가 압력강하에 미치는 영향)

  • Nam Ho Yun;Kim Jong Man;Choi Jong Hyeun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.659-662
    • /
    • 2002
  • The present paper presents the experimental results for pressure drop in inclined tube bundles located in a rectangular duct. Measurements are made for pressure drop in triangular and rotated triangular tube arrays having P/d ratio of 1.6 and inclination angles of 30,45,60 and 90 degrees. The Reynolds number based on the free stream velocity and tube diameter ranges from $8{\times}10^2\;to\;6.3{\times}10^{4}$. The experimental results show that the magnitude of dimensionless pressure drop decreases significantly when the inclined angle is less than 45 degree. The measured data are compared with two existing correlations available in the literatures. The ESDU correlation agrees well with the present data far the triangular arrays. But some discrepancies are observed for the rotated triangular arrays when the inclined angles are 30 and 45 degrees. The Idel'chik correlation generally agrees well with the measured data for the rotated triangular arrays except for the inclined angle of 30 degree. The Idel'chik correlation needs modification for the triangular arrays. The modified Idel'chik correlation agrees well with the measured data within $10{\%}$. It is found that the present measured data can be applied to the evaluation and modification of previous correlations.

  • PDF