• 제목/요약/키워드: Liquid tube

검색결과 535건 처리시간 0.031초

디젤엔진 배출가스의 질소산화물 저감을 위한 Solid SCR용 가스분사 시스템의 전산유체해석 연구 (CFD Analysis on Gas Injection System of Solid SCR for NOx Reduction of Exhaust Emissions in Diesel Engine)

  • 이호열;윤천석;김홍석
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.73-83
    • /
    • 2014
  • CFD(computational fluid dynamics) model is developed to simulate direct injection of ammonia gas phase from ammonia transporting materials into the SCR catalyst in the exhaust pipe of the engine with solid SCR. Configurations of one-hole and four-hole nozzle, circumferential type, porous tube type, and the effect of mixer configurations which commonly used in liquid injection of AdBlue are considered for complex geometries. Mal-distribution index related to concentration of ammonia gas, flow uniformity index related to velocity distribution, and pressure drop related to flow resistance are compared for different configurations of complex geometries at the front section of SCR catalyst. These results are used to design the injection system of ammonia gas phase for solid SCR of target vehicle.

Rapid Preparation of Total Nucleic Acids from E. coli for Multi-purpose Applications

  • Cheng, Lin;Li, Tai-Yuan;Zhang, Yi
    • BMB Reports
    • /
    • 제37권3호
    • /
    • pp.351-355
    • /
    • 2004
  • Separate protocols are commonly used to prepare plasmid DNA, chromosomal DNA, or total RNA from E. coli cells. Various methods for the rapid preparation of plasmid DNA have been developed previously, but the preparation of the chromosomal DNA and total RNA are usually laborious. We report here a simple, fast, reliable, and cost-effective method to extract total nucleic acids from E. coli by direct lysis of the cells with phenol. Five distinct and sharp bands, which correspond to chromosomal DNA, plasmid DNA, 23S rRNA, 16S rRNA, and a mixture of small RNA, were observed when analyzing the prepared total nucleic acids on a regular 1-2% agarose gel. The simple and high-quality preparation of the total nucleic acids in a singe tube allowed us to rapidly screen the recombinant plasmid, as well as to simultaneously monitor the change of the plasmid copy number and rRNA levels during the growth of E. coli in the liquid medium.

헬리컬 흡수기의 흡수 열물질전달 해석 (Analysis of Heat and Mass Transfer on Helical Absorber)

  • 권오경;임종극;윤정인;김선창;윤재호
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1428-1436
    • /
    • 2000
  • The absorption of vapor involves simultaneous heat and mass transfer in the vapor/liquid system. In this paper, a numerical study for vapor absorption process into LIBr-H$_2$O solution film flowing over helical absorber has been carried out. Axisymmetric cylindrical coordinate system was adopted to model the helical tube and the transport equations were solved by the finite volume method. The effects of operating conditions, such as the cooling water temperature. the system pressure, the film Reynolds number and the solution inlet concentration have been investigated in view of the absorption mass flux and the total absorption mass flux and the total absorption rate. The results for the temperature and concentration profiles, as well as the local absorption mass flux at the helical absorber are presented. It is shown that solution inlet concentration affected other than operation conditions for a mass flux.

서울대기중 아질산기체의 계절별 농도변화 (Concentration and Seasonal Variation of Gaseous Nitrous Acid in Seoul Air)

  • 이용근;김종욱;이동수;백선영
    • 한국대기환경학회지
    • /
    • 제10권1호
    • /
    • pp.24-31
    • /
    • 1994
  • Hourly variation of gaseous nitrous acid( HNO$_2$) concentration in Seoul air was monitored from Jan. 11 to SeP. 12, Nitrous acid concentration was determined by DS/IC over nine months of observation, HNO$_2$ range from 0.04 ppb to 5.5 ppb. Gor-tex tube as gaseous HNO$_2$generator in this study is thought to be more convenient and reproducible device than previous generator. As a result of NaOH instead of Na$_2$ CO$_3$/NaHCO$_3$ solution as the IC eluent, we could obtain more stable baseline. The concentration of the NaOH eluent was 15 mM . The limit of detection(3$\sigma$) of the liquid- Phase and gas phase nitrous acid of this method are 1.1ng/$m\ell$ , 0.04 n $\ell$ / $\ell$, respectively. The precisions evaluated by 10 replicate analysis of standard solution and standard gas generated are $\pm$1.59, $\pm$2. 89% RSD, respectively. Due to the lack of standard material for air, direct assessment of the accuracy was not possible. This study was applied to the analysis of Seoul ambient air and their results are reported herein.

  • PDF

양액 자동조제용 액제 정밀계량 장치 개발 (Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control)

  • 이정훈;류관희;이규철
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 동계 학술대회 논문집
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

미립잠열슬러리의 유체역학적 특성연구 (Fluid dynamical characteristics of microencapsulated phase change material slurries)

  • 이효진;이승우;이재구
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

순수 및 혼합냉매의 유동증발 열전달 상관식 (Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures)

  • 신지영;김민수;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF

스핀 온 소스를 이용한 함몰형 전극 형성을 위한 확산 (Diffusion of buried contact grooves with spin-on source)

  • A.U. Ebong;S.H. Lee
    • 한국결정성장학회지
    • /
    • 제6권3호
    • /
    • pp.424-430
    • /
    • 1996
  • 태양전지의 공정중 고온공정을 줄여줌으로서 최종 태양전지의 가격을 저가화할 수가 있다. 이 논문은 점액 상태의 인을 희석시켜서 접촉 홈에 확산공정을 마친 후, 그 기본 특성을 조사하였다. 점액상태점의 희석도와 스핀속도가 산화막의 두께에 영향을 미치는 것이 확인되었다. 희석도가 높을수록 산화막은 두꺼워지고 균일도는 낮아졌다. 희석도 60%의 인이 홈에서의 균일도와 깊이를 고려할 때 가장 적당한 것으로 사료된다.

  • PDF

액체질소로 냉각된 Bi-2223 선재의 퀜치 전파 특성에 관한 연구 (A Study on the Quench Propagation Properties of Bi-2223 Wire cooled in Liquid Nitrogen)

  • 윤경용;배덕권;안민철;강형구;이찬주;윤용수;이상진;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.32-36
    • /
    • 2005
  • With the successful commercialization of Bi-2223 powder-in-tube wire , various attempts in the R & D of the high-Tc superconducting (HTS) magnets for high magnetic field applications are being implemented actively. Operating temperature of HTS magnet has to be maintained at the designed level but the magnetic energy and mechanical disturbance can cause unstable operational temperature of HTS magnet. Especially the generated heat energy of inner HTS winding Is apt to be accumulated . so the normal region appears in HTS winding. This paper deals with the quenching characteristics of three kinds of selected Bi-2223 wires : the High Current Density Wire (HC-A) and the High Strength Wire (HS-A) made by AMSC and HTS wire(HW-I) made by Innost The Innost wire has the highest minimum quench energy (MQE). The High Current Density Wire has the highest normal zone Propagation velocity (NZPV).

Bi-계 고온초전도 선재의 제조 및 특성 연구 (A study on the fabrication and characterization of high temperature superconducting(HTS) tapes in Bi-System)

  • 정년호;성태현;한영희;한상철;이준성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.474-477
    • /
    • 2002
  • We performed a continuous heat treatment experiment for long Si$_2$Sr$_2$CaCuO$_{x}$ (Bi2212) superconductor tapes on copper substrates. A precursor that contains a mixture of Bi$_2$O$_3$, SrCO$_3$, and CaCO$_3$ powders was prepared and screen-printed on Cu tapes. The screen- printed tapes were thermally treated by consecutive processes with various temperature settings using an air-filled tube furnace. The diffraction patterns and the microstructures of the high temperature superconductor thick films were analyzed by X-ray diffractometry (XRD) and optical Microscopy respectively, and the critical temperatures of the superconducting thick films were measured. The critical temperatures of the superconducting films were measured to be about 77K, and the films'crystallographic c-axes were confirmed to be normal to the film surfaces by XRD and morphology observation. We also observed that the thick superconducting layer is formed and aligned on the copper substrate via partial melted state that consists of a liquid phase and a secondary phase.e.

  • PDF