• 제목/요약/키워드: Liquid temperature field measurement

검색결과 34건 처리시간 0.023초

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

과도액정기법을 이용한 열전달 측정 및 수치해석 (Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis)

  • 홍철현;이기백;양장식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

Simple Technique for Measurement of Complex Permittivity and Detection of Small Permittivity Change Using Partially Open Cavity

  • Park, Sangbok;Chung, Young-Seek;Cheon, Changyul
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.268-272
    • /
    • 2014
  • This letter presents a measurement methodology of the complex permittivity of liquid using a partially open cavity in narrow band. The partially open cavity (POC) can measure dielectric small changes caused by the temperature variation of the liquid inside the cavity as well. Using the resonance frequency and unloaded quality factor of the proposed POC, the complex permittivity is evaluated. The apertures on the walls of the cavity are designed to circulate the liquid inside to outside of the POC and located at the corner area of the cavity to minimize the disturbance of field distribution at the dominant mode. The results measured by the proposed POC were compared with those by the conventional open-ended probe and Cole-Cole equation. The POC showed better performance in measuring small dielectric constant changes than the open-ended probe.

Measurement of temperature profile using the infrared thermal camera in turbulent stratified liquid flow for estimation of condensation heat transfer coefficients

  • Choi, Sung-Won;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.107-107
    • /
    • 1999
  • Direct-contact condensation experiments of atmospheric steam and steam/air mixture on subcooled water flowing co-currently in a rectangular channel are carried out uszng an infrared thermal camera system to develop a temperature measurement method. The inframetrics Model 760 Infrared Thermal Imaging Radiometer is used for the measurement of the temperature field of the water film for various flow conditions. The local heat transfer coefficient is calculated using the bulk temperature gradient along the (low direction. It is also found that the temperature profiles can be used to understand the interfacial condensation heat transfer characteristics according to the flow conditions such as noncondensable gas effects, inclination effect, and flow rates.

  • PDF

감온액정을 이용한 Rayleigh-Bernard 대류의 정량적 가시화에 관한 연구 (A Study on the Quantitative Visualization of Rayleigh-Bernard Convection Using Thermochromic Liquid Crystal)

  • 배대석;김진만;권오봉;이동형;이연원;김남식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.395-404
    • /
    • 2003
  • Quantitative data of the temperature and velocity were obtained simultaneously by using liquid crystal tracer. PIV(Particle Image Velocimety) based on a grey-level cross-correlation method was used for visualizing and analysis of the flow field. The temperature gradient was obtained by applying the color-image processing to a visualized image, and a neural-network a1gorithm was applied to the color-to-temperature calibration. This simultaneous measurement was applied to the Rayleigh-Bernard convection. This paper describes the method, and presents the quantitative visualization of Rayleigh-Bernard convection and the effect of aspect ratio and viscosity. Also the experimental results were compared with the numerical results.

Magnetic levitation properties of single- and multi-grain YBCO bulk superconductors

  • Kim, C.J.;Yang, A.Y.;Lee, S.H.;Jun, B.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.52-56
    • /
    • 2022
  • Single-grain (c-normal or c-parallel) and multi-grain YBCO superconductors were prepared by a melt growth process with/without seeding. The magnetic levitation force and trapped magnetic field at liquid N2 temperature (77 K) of the YBCO superconductors were investigated. Samples for the levitation force measurement were zero-field cooled (ZFC) to 77 K, and samples for trapped field measurement were field-cooled (FC) using Nd magnets. As for the magnetic levitation force, the c-normal, single grain sample showed the largest value, whereas the multi-grain sample showed the lowest value. The trapped magnetic field of the c-normal and c-parallel single-grain samples was 4-5 times that of the multi-grain sample. In addition, as the external magnetic field (the number of magnets) increased, the both properties increased proportionally. These results were explained in terms of the orientation dependence of the levitation forces and the magnetic field trapping capability of the YBCO superconductor.

Review of Experimental Studies on Swirling Flow in the Circular Tube using PIV Technique

  • Chang, Tae-Hyun;Nah, Do-Baek;Kim, Sang-Woo
    • 한국가시화정보학회지
    • /
    • 제7권1호
    • /
    • pp.21-28
    • /
    • 2009
  • The study of swirling flow is of technical and scientific interest because it has an internal recirculation field, and its tangential velocity is related to the curvature of streamline. The fluid flow for tubes and elbow of heat exchangers has been studied largely through experiments and numerical methods, but studies about swirling flow have been insufficient. Using the particle image velocimetry(PTV) method, this study found the time averaged velocity distribution with swirl and without swirl along longitude sections and the results appear to be physically reasonable. In addition, streamwise mean velocity distribution was compares with that of other. Furthermore, other experimental investigation was performed to study the characteristics of turbulent water flow in a horizontal circular tube by using liquid crystal. 2D PIV technique is employed for velocity measurement and liquid crystal is used for heat transfer experiments in water. Temperature visualization was made quantitatively by calibrating the colour of the liquid crystal versus temperature using various approaches.

이량체액정의 PVT측정과 상전이 거동 (PVT Measurement and Phase Transition Behavior of Dimer Liquid Crystals)

  • 남수용
    • 한국인쇄학회지
    • /
    • 제14권1호
    • /
    • pp.17-29
    • /
    • 1996
  • N-substituted acrylamide hydrogel is reported to have the feature of bing transparent and sensitive enough to response to a temperature stimulus below the temperature of phase transition. Especially at the near of 35 C it becomes shrunk and opaque very quickly. It has also the characteristic of reversing swelling and shrinking. The experiment showed that it is possible to produce a functional gel of super water absorption with the process of free radical polymerizing PVA(polyvinylalcohol) and PAA(polyacrylamide), and crosslinking. The ratio of shrinking and swelling caused by copolymerization rises 10% to 80% at the each temperature of 20 C, 30 C, 40 C, respectively. Phase transition temperature of this gel by copolymerization is50 C while that of ordinary N-substituted acrylamides is between 32~35 C. This temperature reaches the rearing limit of animals and plants so that volumetric transition polymer gel can be ulilized in varying fields such as agriculture/gardening which are water-using field, on-off switch sensing temperature and volumetric variation, processing of liquid wastes and civil engineering works, architecture and electronics. We have no doubt that this material will be the high-functional resin in the hi-tech age of the near future.

  • PDF

LIF 및 CLSM을 결합한 미소 간극 내 유체의 단면 온도 분포 측정 기법 (Measurement of Cross-sectional Temperature Distribution in Micro-scale Gap Fluid Using LIF Technique in Combination with CLSM)

  • 정동운;이상용
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.834-841
    • /
    • 2006
  • In the present wort the Laser-induced Fluorescence (LIF) technique and Confocal Laser Scanning Microscopy (CLSM) have been combined to measure the temperature distribution across a micro-scale liquid layer as a direct and non-invasive method. Only the fluorescent light emitted from a very thin volume around a focal plane can be selectively detected, and it enables us to measure the liquid temperatures even at the close vicinity of the walls. As an experimental verification, a test section consists of two flat plates (for heating and cooling, respectively) separated by about 240 microns was made, and the methanol mixed with a temperature-sensitive dye, Rhodamine B, was filled in the gap between them. The measured temperature distribution across the gap showed good linearity, which is a typical characteristic of conduction heat transfer through a thin liquid layer. In result, the CLSM-LIF technique proposed in the present study was found to be a promising method to measure the local temperatures in the liquid flow field in microfluidic devices.

신경망을 이용한 온도장 측정법 개선 방안 (Improvements of Temperature Field Measurement Technique using Neural Network)

  • 황태규;문지섭;장태현;도덕희
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.52-55
    • /
    • 2004
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. $1K\times1K$ CCD color camera and Xenon Lamp(500W) were used for the visualization of a Hele-Shaw cell. The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity. A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.

  • PDF