• Title/Summary/Keyword: Liquid sensor

Search Result 316, Processing Time 0.026 seconds

Research on the Variable Rate Spraying System Based on Canopy Volume Measurement

  • Hu, Kaiqun;Feng, Xin
    • Journal of Information Processing Systems
    • /
    • v.15 no.5
    • /
    • pp.1131-1140
    • /
    • 2019
  • Characteristics of fruit tree canopies are important target information for adjusting the pesticide application rate in variable rate spraying in orchards. Therefore, the target detection of the canopy characteristics is very important. In this study, a canopy volume measurement method for peach trees was presented and a variable rate spraying system based on canopy volume measurement was developed using the ultrasonic sensing, one of the most effective target detection method. Ten ultrasonic sensors and two flow control units were mounted on the orchard air-assisted sprayer. The ultrasonic sensors were used to detect the canopy diameters and the flow controls were used to modify the flow rate of the nozzles in real time. Two treatments were established: a constant application rate of $300Lha^{-1}$ was set as the control treatment for the comparison with the variable rate application at a $0.095Lm^{-3}$ canopy. The tracer deposition at different parts of peach trees and the tracer losses to the ground (between rows and within rows) were analyzed in detail under constant rate and variable rate application. The results showed that there were no significant differences between two treatments in the liquid distribution and the capability to reach the inner parts of the crop canopies.

Feasibility Study of the Application of Infinite Tube Probe in High Temperature Environment (고온 환경에서 무한 튜브 검출기의 적용에 관한 타당성 연구)

  • Kim, Hyeonjun;Ryu, Chulsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.108-119
    • /
    • 2020
  • Dynamic pressure sensor used in liquid rocket engine combustor and gas turbine is recess-mounted usually because it should work in high temperature environment. Although recess-mounted method can protect it from combustion gas in high temperature, tube resonance occurs in a tube-cavity system. To reduce it, the infinite tube probe(ITP) was introduced in this study. The ITP model suggested in previous literature was validated with experimental data and frequency response characteristics were analyzed. Guidelines for designing the ITP were suggested as frequency response profiles varied with geometric information and physical properties using this model.

A real-time unmeasured dynamic response prediction for nuclear facility pressure pipeline system

  • Seungin Oh ;Hyunwoo Baek ;Kang-Heon Lee ;Dae-Sic Jang;Jihyun Jun ;Jin-Gyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2642-2649
    • /
    • 2023
  • A real-time unmeasured dynamic response prediction process for the nuclear power plant pressure pipeline is proposed and its performance is tested in the test-loop system (KAERI). The aim of the process is to predict unmeasurable or unreachable dynamic responses such as acceleration, velocity, and displacement by using a limited amount of directly measured physical responses. It is achieved by combining a well-constructed finite element model and robust inverse force identification algorithm. The pressure pipeline system is described by using the displacement-pressure vibro-acoustic formulation to consider fully filled liquid effect inside the pipeline structure. A robust multiphysics modal projection technique is employed for the real-time sensor synchronized prediction. The inverse force identification method is also derived and employed by using Bathe's time integration method to identify the full-field responses of the target system from the modal domain computation. To validate the performance of the proposed process, an experimental test is extensively performed on the nuclear power plant pressure pipeline test-loop under operation conditions. The results show that the proposed identification process could well estimate the unmeasured acceleration in both frequency and time domain faster than 32,768 samples per sec.

Study on High Sensitivity Metal Oxide Nanoparticle Sensors for HNS Monitoring of Emissions from Marine Industrial Facilities (해양산업시설 배출 HNS 모니터링을 위한 고감도 금속산화물 나노입자 센서에 대한 연구)

  • Changhan Lee;Sangsu An;Yuna Heo;Youngji Cho;Jiho Chang;Sangtae Lee;Sangwoo Oh;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.30-36
    • /
    • 2022
  • A sensor is needed to continuously and automatically measure the change in HNS concentration in industrial facilities that directly discharge to the sea after water treatment. The basic function of the sensor is to be able to detect ppb levels even at room temperature. Therefore, a method for increasing the sensitivity of the existing sensor is proposed. First, a method for increasing the conductivity of a film using a conductive carbon-based additive in a nanoparticle thin film and a method for increasing ion adsorption on the surface using a catalyst metal were studied.. To improve conductivity, carbon black was selected as an additive in the film using ITO nanoparticles, and the performance change of the sensor according to the content of the additive was observed. As a result, the change in resistance and response time due to the increase in conductivity at a CB content of 5 wt% could be observed, and notably, the lower limit of detection was lowered to about 250 ppb in an experiment with organic solvents. In addition, to increase the degree of ion adsorption in the liquid, an experiment was conducted using a sample in which a surface catalyst layer was formed by sputtering Au. Notably, the response of the sensor increased by more than 20% and the average lower limit of detection was lowered to 61 ppm. This result confirmed that the chemical resistance sensor using metal oxide nanoparticles could detect HNS of several tens of ppb even at room temperature.

Effect of Irrigation of River Water and Swine Slurry Liquid Fertilizer on Kenaf (Hibiscus cannabinus L.) Growth Cultivated Using Soil Moisture Control System in Reclaimed Land (자동 수분 제어시스템을 이용한 간척지 케나프 재배시 하천수 및 액비 관개 효과)

  • Kang, Chan-Ho;Lee, In-Sok;Lee, Jin-Jae;Kim, Hee-Jun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.1
    • /
    • pp.87-96
    • /
    • 2021
  • Information and Communication Technology (ICT) remote soil moisture control system including soil sensing, automatic water supply chain, and remote alarming system was established on reclaimed land and operated stably. The system was operated using river water around the reclaimed land without fertilizer. On applying this system to control soil moisture, the kenaf germination rate was improved up to two times. Kenaf biomass was 4,748 kg/10a and was higher than that of untreated soil moisture management. When the nutritious liquid fertilizer was used, kenaf yield reached 8,390 kg/10a, which was lower than 10,848 kg/10a of the non-reclaimed land treated with standard chemical fertilizers. As the soil moisture was managed stably through the ICT remote soil moisture control system, the quality of the kenaf crop was improved, resulting in a 7% increase in dry weight, and a 11.5% increase in plant hardness. The estimated kenaf yield was 5,039 kg/10a when 800 tonnes of water were supplied by the ICT remote soil moisture control system with the stream water around Saemangeum reclaimed land without chemical fertilizers and organic matter.

First-order Wire-wound SQUID Gradiometer System Having Compact Superconductive Connection Structure between SQUID and Pickup Coil (SQUID와 검출코일의 초전도 결합방식이 개선된 1차 권선형 미분계 시스템)

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Kwon, H.;Kim, K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2007
  • In order to have a superconductive connection between the wire-wound pickup coil and input coil, typically Nb terminal blocks with screw holes are used. Since this connection structure occupies large volume, large stray pickup area can be generated which can pickup external noise fields. Thus, SQUID and connection block are shielded inside a superconducting tube, and this SQUID module is located at some distance from the distal coil of the gradiometer to minimize the distortion or imbalance of uniform background field due to the superconducting module. To operate this conventional SQUID module, we need a higher liquid He level, resulting in shorter refill interval. To make the fabrication of gradiometers simpler and refill interval longer, we developed a novel method of connecting the pickup coil into the input coil. Gradiometer coil wound of 0.125-mm diameter NbTi wires were glued close to the input coil pads of SQUID. The superconductive connection was made using an ultrasonic bonding of annealed 0.025-mm diameter Nb wires, bonded directly on the surface of NbTi wires where insulation layer was stripped out. The reliability of the superconductive bonding was good enough to sustain several thermal cycling. The stray pickup area due to this connection structure is about $0.1\;mm^2$, much smaller than the typical stray pickup area using the conventional screw block method. By using this compact connection structure, the position of the SQUID sensor is only about 20-30 mm from the distal coil of the gradiometer. Based on this compact module, we fabricated a magnetocardiography system having 61 first-order axial gradiometers, and measured MCG signals. The gradiometers have a coil diameter of 20 mm, and the baseline is 70 mm. The 61 axial gradiometer bobbins were distributed in a hexagonal lattice structure with a sensor interval of 26 mm, measuring $dB_z/dz$ component of magnetocardiography signals.

  • PDF

$CO_2$ Sensing Characteristics of Carbon-nanofibers Based on Effects of Porosity and Amine Functional Group (다공성 및 아민 작용기에 따른 탄소나노섬유의 $CO_2$ 감응특성)

  • Kim, Jong Gu;Kang, Seok Chang;Shin, Eunjeong;Kim, Da Young;Lee, Jin Hee;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • Porous carbon nanofibers were prepared as a gas sensor electrode to study the $CO_2$ sensing property based on effects of porosity and introduced amine functional groups. Electrospun fibers were obtained by using electrospinning method with polyacrylonitrile precursor and they were treated by the thermal treatment and chemical activation. Amine functional groups were introduced by the liquid state treatment using diethylenetriamine. The specific surface area increased up to $2000m^2/g$ by the chemical activation. The Introduced amine functional group was identified using FT-IR spectroscopy. $CO_2$ gas sensing property was improved as four folds via introduced amine functional groups on the activated carbon nanofiber. In conclusion, the gas sensing property was improved based on the developed porosity by the chemical activation and the chemical attraction of $CO_2$ gas by introduced functional groups.

An Array-Type RGB Sensor for Precision Measurement of pH

  • Kim, Ji-Sun;Oh, Han-Byeol;Kim, A-Hee;Kim, Jun-Sik;Lee, Eun-Suk;Goh, Bong-Jun;Choi, Ju-Hyeon;Shin, Ye-Ji;Baek, Jin-Young;Lee, Ki Sung;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.700-704
    • /
    • 2015
  • As pH is a widely used index in chemical, medical, and environmental applications, research on pH sensors has been active in recent years. This study obtained RGB values by measuring the reflected light from a liquid sample to detect fine changes in pH, and performed mathematical modeling to investigate the relationship between the detected optical signal and pH value. Also, the trends in pH changes were easily identified by analyzing RGB values and displaying them in the color coordinate for easy visualization of data. This method implemented a user-friendly system that can measure and analyze in real time. This system can be used in many fields such as genetic engineering, environmental engineering, and clinical engineering, because it not only can measure pH but also replaces a colorimeter or turbidimeter.

Measurement and Analysis of the Dynamics of Peptide-Antibody Interactions Using an Ellipsometric Biosensor Based on a Silicon Substrate (실리콘 기판을 사용한 바이오센서와 회전 타원분광계를 이용한 펩타이드-항체 접합의 동특성 측정과 분석)

  • Lee, Geun-Jae;Cho, Hyun Mo;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • We precisely measured and analyzed the dynamics of peptide-antibody interactions, using an ellipsometric biosensor based on a silicon substrate. To reduce the signal error due to the imperfect flatness of the substrate for extremely low concentrations of peptide, we fabricated the biosensor with a silicon substrate coated with Dextran SAM, instead of a glass prism coated with a thin metallic thin film. At an injection speed of $100{\mu}l/min$ of buffer liquid, we detected the dynamics of antibody-Dextran SAM or peptide-antibody fixed on biosensor, respectively. We detected the dynamics of antibody-Dextran SAM interactions down to a low concentration of 5 ng per liter, and we precisely measured the dynamics of association and dissociation of peptide and antibody down to 100 nM of peptide. We obtained the rate constants for association and dissociation from fitting the data by using deduced dynamical equation. As a result, we obtained an equilibrium constant for dissociation of 97 nM of peptide-antibody complex, which belongs to Class I.

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$