• Title/Summary/Keyword: Liquid pump

Search Result 454, Processing Time 0.023 seconds

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.63-70
    • /
    • 1992
  • The aim of this research is to obtain a basic quantitative understanding of the effect of a noncondensable gas on the absorption of water vapor by a $H_2O$ / LiBr combination with n-octanol as the surfactant. Nonflowing aqueous solutions of LiBr (40,45,50 mass%) were exposed to saturated water vapor following the addition of an n-octanol sufactant (0.01 and 0.6 mass%). A small amount of a noncondensable gas (air) was allowed into the absorber (0.03 volume%) and its effect was analyzed by measuring the amount of water vapor absorbed. This study will aid to predict the performance of heat pump and safety operating condition when the noncondensable gas is not allowed in the absorber The results indicate that, in the presence of small amounts of a noncondensable gas, vapor absorption enhancement ratios are less than half o( those obtained under the same experimental conditions when a noncondensable gas is not present (1). The presence of a noncondensable gas causes the partial vapor pressure of air to increase at the vapor / liquid interface, which results in an instability of vapor absorption rate nd. hence, in an inhibition of interfacial disturbance.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF