• Title/Summary/Keyword: Liquid phase reduction method

검색결과 59건 처리시간 0.024초

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons and Their Nitro-derivatives in Airborne Particulates by Using Two-dimensional High-performance Liquid Chromatography with On-line Reduction and Fluorescence Detection

  • Boongla, Yaowatat;Orakij, Walaiporn;Nagaoka, Yuuki;Tang, Ning;Hayakawa, Kazuichi;Toriba, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권4호
    • /
    • pp.283-299
    • /
    • 2017
  • An analytical method using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection was developed for simultaneously analyzing 10 polycyclic aromatic hydrocarbons (PAHs) and 18 nitro-derivatives of PAHs (NPAHs). The two-dimensional HPLC system consists of an on-line clean-up and reduction for NPAHs in the 1st dimension, and separation of the PAHs and the reduced NPAHs and their FL detection in the 2nd dimension after column-switching. To identify an ideal clean-up column for removing sample matrix that may interfere with detection of the analytes, the characteristics of 8 reversed-phase columns were evaluated. The nitrophenylethyl (NPE)-bonded silica column was selected because of its shorter elution band and larger retention factors of the analytes due to strong dipole-dipole interactions. The amino-substituted PAHs (reduced NPAHs), PAHs and deuterated internal standards were separated on polymeric octadecyl-bonded silica (ODS) columns and by dual-channel detection within 120 min including clean-up and reduction steps. The limits of detection were 0.1-9.2 pg per injection for PAHs and 0.1-140 pg per injection for NPAHs. For validation, the method was applied to analyze crude extracts of fine particulate matter ($PM_{2.5}$) samples and achieved good analytical precision and accuracy. Moreover, the standard reference material (SRM1649b, urban dust) was analyzed by this method and the observed concentrations of PAHs and NPAHs were similar to those in previous reports. Thus, the method developed here-in has the potential to become a standard HPLC-based method, especially for NPAHs.

Reduction of viewing-angle dependent color shift in a reflective type cholesteric liquid crystal color filter

  • Jang, Won-Gun;Beom, Tae-Won;Cui, Hao;Park, Jong-Rak;Hwang, Seong-Jin;Lim, Young-Jin;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1656-1659
    • /
    • 2008
  • The reflective type color filter for the liquid crystal displays (LCD) was produced using cholesteric liquid crystal monomers whose phase is characterized by the unique optical features of selective reflection. Periodic micrometer scale hemi-spherical photoresist (PR) patterns were formed on glass substrates by thermal reflow method after photolithography. Cholesteric color filter films for red, green and blue light reflections were then produced and the viewing angle dependence was investigated and compared with that of reflected light on the non-patterned substrates.

  • PDF

광합성 세균을 이용한 고농도 양돈슬러리의 무취화 관리방안에 관한 연구 (Deodorization Management of Swine-Slurry by Addition of Phototrophic Bacteria)

  • 이명규;권오중;정진영;태민호;허재숙
    • 한국축산시설환경학회지
    • /
    • 제4권2호
    • /
    • pp.137-147
    • /
    • 1998
  • This study was carried out to find deodorization effect of swine-slurry by addition of phototrophic bacteria(PTB). The pilot-scale reactors operation conditions was designed by the inoculum amounts of PTB and light-conditions. Treatment conditions was divided into 3 types; 106 MPN/ml$.$Dark(T-1), 108 MPN/ml$.$Dark(T-2), 108 MPN/ml$.$Natural light(T-3). The changes of the concentration of volatile fatty acids(VFAs), hydrogen sulfide(H2S), ammonia (NH3) and odor intensity were analyzed during the treatment period(35 days). From results of this study, the maximum intensity of odor in the headspace of the reactor T-1 was 4.82 and T-2, T-3 was 2.63, respectively. In swine-slurry of reactors used, it almost took 10 days until to be stabilized with solid and liquid phase. Intensity of odor in headspace was mainly derived from the liquid phase. The PTB inoculum method to swine-slurry was very effective in reduction of VFAs, H2S and Sulfate-reducing bacteria(SRB) concentration. Expecially, It was interested in reverse growth behaviour of SRB and PTB in these conditions.

  • PDF

반용융 재료의 압출공정에 관한 유한요소 해석 (Finite Element Analysis of Extrusion Process in Semi-Solid State)

  • 황재호;고대철;민규식;김병민;최재찬
    • 소성∙가공
    • /
    • 제7권4호
    • /
    • pp.364-374
    • /
    • 1998
  • It is the objective of this study to analyze the effect of various process variables on the quality of extruded product and extrusion force for semi-solid extrusion of Al2024 with solid phase structure of globular type by the finite element method. Process variables are initial solid fraction, ram speed, semi-angle of die, and reduction in area. The results of experiment are compared with those of simulation in order to verify the usefulness of the developed finite element program. The flow and deformation of semi-solid alloy are analyzed by coupling by coupling the deformation of porous skeleton and the flow of liquid phase. It is also assumed that initial solid fraction is homogeneous.

  • PDF

액상환원법을 이용하여 합성된 은 나노입자의 적외선 흡수 및 반사 특성 (Infrared Absorption and Reflection Properties of Silver Nanoparticles Synthesized by Liquid Reduction Method)

  • 홍민지;박민지;김종화;;진영읍;이근대;박성수
    • 공업화학
    • /
    • 제28권5호
    • /
    • pp.587-592
    • /
    • 2017
  • 액상환원법을 통하여 출발 물질인 질산은 용액으로부터 환원 용매인 DMF와 환원제 및 계면활성제 역할을 하는 PVP를 이용하여 여러 합성 조건에서 균일하면서 적당한 크기의 은 나노판상체를 합성하고자 하였다. 합성 시료 및 필름시편들의 특성들은 SEM, TEM, UV-Vis-NIR 분광법, PSA 및 XRD를 사용하여 비교 조사하였다. 질산은 용액과 DMF에 26 wt%의 PVP가 첨가된 반응물을 $70^{\circ}C$에서 72 h 동안 반응하여 합성한 시료에는 약 100~200 nm 크기의 삼각형판상체들로 존재하였고, 약 1,000 nm에서 최대 흡수 피크를 나타내므로 근적외선을 가장 잘 반사시키는 시료로 예측하였다. 필름용 코팅액에서 은 나노판상체의 함유량이 증가하거나 이의 크기가 증가되면, 필름 시편의 투과율은 떨어지고 반사율은 높아지는 경향을 나타내었다.

Effect of Preparation Conditions on the Hydrogenation Activity and Metal Dispersion of Pt/C and Pd/C Catalysts

  • Jhung, Sung-Hwa;Lee, Jin-Ho;Lee, Jong-Min;Lee, Ji-Hye;Hong, Do-Young;Kim, Myong-Woon;Chang, Jong-San
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.563-568
    • /
    • 2005
  • The Pt/C and Pd/C catalysts were prepared from conventional chloride precursors by adsorption or precipitation-deposition methods. Their activities for hydrogenation reactions of cyclohexene and acetophenone were compared with those of commercial catalysts. The Pt/C and Pd/C catalysts obtained from the adsorption procedure reveal higher hydrogenation activity than commercial catalysts and the catalysts prepared by the precipitation-deposition method. Their improved performances are attributed to the decreased metal crystallite sizes of Pt or Pd formed on the active carbon support upon the adsorption of the precursors probably due to the same negative charges of the chloride precursor and the carbon support. Under the preparation conditions studied, the reduction of the supported catalysts using borohydrides in liquid phase is superior to a gas phase reduction by using hydrogen in the viewpoint of particle size, hydrogenation activity and convenience.

고성능 액체크로마토그래피(HPLC)를 이용한 3가, 6가 크롬의 동시정량에 관한 연구 (Simultaneous Determination of Chromium (III) and Chromium(VI) by High Performance Liquid Chromatography(HPLC))

  • 노재훈;김치년;김춘성;김규상
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.189-197
    • /
    • 1994
  • Analytic methods for Cr(VI) level in industrial hygienic field were suggested by the National Institute for Occupational Safety and Health(NIOSH method 7600, 7604). There were growing needs for measurement of Cr(III) and Cr(VI) levels simultaneously. Two analytical methods were suggested to determine Cr(III) and Cr(VI) levels simultaneously. The one is method by using reversed phase high peformance liquid chromatography(HPLC) and the other is by using ion exchange HPLC. The purpose of this work was to evaluate the usefulness of these two analytic methods. For the difference of ionic charges of Cr(III)-ethylendiamine tetraacetic acid(EDTA) chelate and $CrO_4{^-2}$, we could detect them simultaneously by ion exchange HPLC. Also, we attempted to determine the levels of Cr(III) and Cr(VI) chelated with sodium diethyldithiocarbamate(NaDDTC) by using reversed phase HPLC. The confirmation of Cr(III) and Cr(VI) were checked by fraction collector and nameless atomic absorption spectrometer. The optimal conditions for the formation of Cr(III)-EDTA chelate were two hours incubation period with pH 5. Cr(III)-EDTA and Cr(VI) in EDTA solution were successfully separated by anion exchange column using $Na_2CO_3/NaOH$ mixture as mobile phase. Peaks of Cr(III)-EDTA and Cr(VI) in EDTA were identified at 5 minutes and 7 minutes of retention time respectively by the ion exchange HPLC. The formation of Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates were twelve hours incubation period. Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates were separated by reversed phase column using methanol and water mixture as mobile phase. Peaks of Cr(VI)NaDDTC and Cr(III)-NaDDTC chelates were identified at 13 minutes and 26 minutes of retention time respectively by the reversed phase HPLC. Due to reduction of Cr(VI) to Cr(III), it seems to be not suitable for simultaneous determination of Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates by reversed phase HPLS. Simultaneos determination of Cr(III) and Cr(VI) by ion exchange HPLC was more accurate and simple method.

  • PDF

폴리올 공정과 액상 환원 공정에 따른 은 입자 제조 및 특성 평가 (Fabrication and Characterization of Ag Particles by Polyol Process and Wet Chemical Process)

  • 유주연;장효성;이근재
    • 한국분말재료학회지
    • /
    • 제23권4호
    • /
    • pp.297-302
    • /
    • 2016
  • Ag nanoparticles are extensively studied and utilized due to their excellent catalysis, antibiosis and optical properties. They can be easily synthesized by chemical reduction methods and it is possible to prepare particles of uniform size and high purity. These methods are divided into vapor methods and liquid phase reduction methods. In the present study, Ag particles are prepared and analyzed through two chemical reduction methods using solvents containing a silver nitrate precursor. When Ag ions are reduced using a reductant in the aqueous solution, it is possible to control the Ag particle size by controlling the formic acid ratio. In addition, in the Polyol process, Ag nanoparticles prepared at various temperatures and reaction time conditions have multiple twinned and anisotropic structures, and the particle size variation can be confirmed using field emissions scanning electron microscopy and by analyzing the UV-vis spectrum.

가변추력을 위한 기체주입식 와류형 분사기의 분무특성 (Spray Characteristics of Effervescent Swirl Injectors for Variable Thrust)

  • 이원구;황동현;안규복;윤영빈
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.1-12
    • /
    • 2019
  • 액체로켓엔진에서의 추력조절을 위해 기체주입식 가변추력 방법에 대한 기초적인 연구를 수행하였다. 기체주입식 가변추력은 간단한 구조로 추력을 조절할 수 있을 뿐만 아니라 밀도 감소에 비례하여 증가된 분사차압에 의해 미립화 성능 증가라는 장점을 갖는다. 본 연구에서는 기체주입식 와류형 분사기를 이용하여 액체 질량유량과 기체주입량의 변화에 따른 분무 불안정, 분무형상, 분무각, 분열 길이와 같은 분무특성을 살펴보았다.

판형 및 다공형 배플을 포함한 탱크 내 슬로싱에 대한 유동해석 (A NUMERICAL ANALYSIS OF THE SLOSHING IN A TANK WITH PLATE/POROUS BAFFLES)

  • 이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.215-222
    • /
    • 2009
  • In the present study, a numerical analysis on the sloshing in a tank with the harmonic motion was investigated. A VOF method was used for two-phase flows inside the sloshing tank and a source term of the momentum equation was applied for the harmonic motion. This numerical method was verified by comparing its results with the available experimental data. The sloshing in a tank causes the instability of the fluid flows and the fluctuation of the impact pressure on the tank. By these phenomena of the tank sloshing, the sloshing problems such as the failure and the noise of system can be generated. For the reduction of these sloshing problems, the various baffles such as the horizontal/vertical plate baffles and the porous baffles inside the tank are installed. With the installations of these baffles, the characteristics of the liquid behavior in the sloshing tank, the impact pressure on the wall, the amplitude of the free surface near the wall and the sloshing noise were numerically analyzed.

  • PDF