• Title/Summary/Keyword: Liquid phase plasma

Search Result 174, Processing Time 0.024 seconds

Sensitive determination of paroxetine in canine plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (LC-MS/MS를 이용한 비글견 혈장 중 파록세틴의 고감도 분석)

  • Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Youm, Jeong-Rok;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.138-146
    • /
    • 2007
  • A simple and sensitive method for the determination of paroxetine in canine plasma was developed and validated by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC-/MS/MS). Fluoxetine was used as an internal standard. Paroxetine and internal standard in plasma samples were extracted using TBME (tert-butyl methyl ether). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 50% acetonitrile adjusted to pH 3 by formic acid. The reconstituted samples were injected into a Capcell Pak UG120 ($2.0{\times}150mm$, $5{\mu}m$) column. Using MS/MS with SRM (selective reaction monitoring) mode, the transitions (precursor to product) monitored were m/z $330{\rightarrow}192$ for paroxetine, and m/z $310{\rightarrow}148$ for internal standard. Linear detection responses were obtained for paroxetine concentration range of 0.02~5 ng/mL. A correlation coefficient of linear regression ($R^2$) was 0.9993. Detection of paroxetine in canine plasma was accurate and precise, with limit of quantification at 0.02 ng/mL. The method has been successfully applied to pharmacokinetic study of paroxetine in healthy beagle dogs.

Sensitive Determination of Pinaverium Bromide in Human Plasma by LC-ESI-MS/MS : Applicability to Oral Bioavailability Determination (LC-ESI-MS/MS를 이용한 생체시료 중 브롬화피나베리움의 고감도 분석 및 이를 이용한 생체이용률 평가)

  • Park, Seok;Lee, Ye-Rie;Kim, Ho-Hyun;Lee, Hee-Joo;Kim, Yoon-Gyoon;Youm, Jeong-Rok;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.6
    • /
    • pp.513-519
    • /
    • 2004
  • A sensitive method for quantification of pinaverium bromide in human plasma was established using liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS). Glimepiride was used as internal standard. Pinaverium bromide and internal standard in plasma sample were extracted using tert-butylmethylether(TBME). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of acetonitrile-5 mM ammonium formate (80/20, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS with multiple reaction monitoring (MRM) mode, pinaverium and glimepirde were detected without severe interference from human plasma matrix. Pinaverium produced a protonated precursor ion $([M+H]^+)$ at m/z 510.3 and a corresponding product ion at m/z 228.9. Internal standard produced a protonated precursor ion $([M+H]^+)$ at m/z 491.5 and a corresponding product ion at m/z 352.0. Detection of pinaverium bromide in human plasma was accurate and precise, with limit of quantitation at 0.5 ng/ml. The method has been successfully applied to bioavailability study of pinaverium bromide tablet in Korean healthy male volunteers. Pharmacokinetic parameters such as $AUC_t,\;C_{max},\;T_{max},\;K_{el}\;and\;t_{1/2}$ were calculated.

Determination of Hydrochlorothiazide in Human Plasma by HPLC and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC를 이용한 혈중 히드로클로로티아지드의 분석 및 이를 이용한 한국인 성인남성에 대한 생체이용률 평가)

  • Park, Ah-Yeon;Kim, Jin-Hee;Kim, Sung-Yong;Chi, Sang-Cheol;Bok, Hae-Sook;Kim, Ho-Jung;Youm, Jeong-Rok;Han, Sang-Beom
    • YAKHAK HOEJI
    • /
    • v.50 no.5
    • /
    • pp.301-307
    • /
    • 2006
  • A simple and sensitive high-performance liquid chromatographic method for quantitation of hydrochlorothiazide in human plasma was developed and bioavailability parameters of hydrochlorothiazide were assessed in Korean healthy male volunteers. Caffeine was used as an internal standard. Hydrochlorothiazide and internal standard in plasma sample were extracted using tert-butylmethylether (TBME). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of acetonitrile-25 mM phosphate buffer (20/80, pH 2.5). The reconstituted samples were injected into a Luna C18 column $(250{\times}4.6\;mm,\;5{\mu}m)$ at a flow-rate of 1.0 ml/min. The wavelength was set at 230 nm and no endogenous substances were found to interfere, A linear relationship for hydrochlorothiazide was found in the range of $10{\sim}300\;ng/ml$. The lower limit of quantitation (LLOQ) was 10 ng/ml with acceptable precision and accuracy. Assayed in plasma, the intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 50mg of hydrochlorothiazide were revealed as follows: $AUC_t\;1761{\pm}509.0\;ng{\cdot} hr\;ml,\;C_{max}\;296.5{\pm}95.5\;ng/ml,\;T_{max}\;1.94{\pm}0.85hr,\;K_{el}\;0.12{\pm}0.04\;hr^{-1}\;and T_{12}\;6.81{\pm}2.92\;hr.\;C_{max}\;and\;T_{max}$ were in accordance with the values $(270{\sim}350\;ng/ml\;and\;1.9{\sim}2.7\;hr)$ of Caucasian.

Capillary Size-exclusion Chromatography as a Gel-free Strategy in Plasma Proteomics

  • Cho, Man-Ho;Wishnok, John S.;Tannenbaum, Steven R.
    • Molecular & Cellular Toxicology
    • /
    • v.1 no.2
    • /
    • pp.87-91
    • /
    • 2005
  • Although 2D-PAGE has been widely used as the primary method for protein separation, difficulties in displaying proteins with an extreme values of isoelectric paint (pI), molecular size and hydrophobicity limit the technique. In addition, time consuming steps involving protein transfer and extraction from the gel-pieces can result in sample loss. Here, we describe a novel protein separation technique with capillary size-exclusion chromatography (CSEC) for rapid protein identification from human plasma. The method includes protein fractionation along with molecular size followed by in-solution tryptic digestion and peptide analysis through reversed phase liquid chromatography (RPLC) coupled to nanoflow electrospray-tandem mass spectrometry (ESI-MS/MS). Tryptic peptides are applied an a $100\;{\mu}m\;i.d.{\times}10mm$ length pre-column and then separated on a $75\;{\mu}m{\times}200mm$ analytical column at -100 nL/min flaw rate. Proteins were identified over the wide ranges of pI (3.7-12.3) when this technique was applied to the analysis of $1-2\;{\mu}L$ of human plasma. This gel-free system provides fast fractionation and may be considered a complementary technique to SDS-PAGE in proteomics.

Pharmacokinetics of Acebutolol and Its Main Metabolite, Diacetolol After Oral Administration of Acebutolol in Rabbits with Carbon Tetrachloride-Induced Hepatic Failure

  • Choi, Jun-Shik;Burm, Jin-Pil
    • Archives of Pharmacal Research
    • /
    • v.25 no.4
    • /
    • pp.541-545
    • /
    • 2002
  • Pharmacokinetic characteristics of Acebutolol and its main metabolite, diacetolol, following a single 10 mg/kg oral dose, were investigated in rabbits with carbon tetrachloride-induced hepatic failure. Plasma concentrations of acebutolol and diacetolol were determined by a high performance liquid chromatography assay. The area under the plasma concentration-time curves (AUC) and maximum plasma concentration ($C_{max}$) of acebutolol were significantly increased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. The ratio of the diacetolol to total acebutolol in plasma (i.e., metabolite percentage rate) was significantly decreased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. Volume of distribution ($V_{d}$) and total body clearance ($CL_{t}$) of acebutolol were significantly decreased in moderate and severe carbon tetrachloride-induced hepatic failure rabbits. Slope of terminal phase ($\beta$) of acebutolol was significantly decreased in hepatic failure rabbits. These findings suggest that the $V_{d},{\;}CL_{t}$ and $\beta$ of acebutolol were significantly decreased as a result of inhibition of the hepatic metabolism in moderate to severe hepatic failure rabbits. Therefore, dose adjustment may be necessary for acebutolol in hypertensive patients with hepatic damage.

A Sensitive and Rapid LC-MS/MS Method for Determination of Berberine in Human Plasma

  • Kim, Jae Hee;Mai, Xuan-Lan;Kim, Kyu Yeon;Sim, Min-Seok;Lee, So-Yeon;Seo, Hee-Won;Lee, Gunhee;Kim, Dae-Jung;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.56-60
    • /
    • 2019
  • Coptidis Rhizoma (CR) has been used widely in traditional medicine to treat common diseases. This study aimed to develop a high-sensitivity liquid chromatography-tandem mass (LC-MS) spectrometry method for the evaluation of the pharmacokinetics of a new natural product that contain CR extract with the main bioactive compound, berberine, at trace concentrations. Human plasma samples were pretreated with methanol by a protein precipitation method. Berberine was analyzed on a Kinetex C18 column ($2.1mm{\times}50mm$, $100{\AA}$, $1.7{\mu}m$) using a mobile phase of 10 mM ammonium formate/0.1% formic acid in water (A) and acetonitrile (B) (50:50, v/v) with a flow rate of 0.25 mL/min. The analyte was detected by using electrospray ionization in positive mode with multiple reaction monitoring (MRM). The method was sensitive, with a lower limit of quantification of 1 pg/mL, which has not been previously obtained. The method was validated (over the range of 1-50 pg/mL) and applied successfully for the pharmacokinetic study of human plasma samples.

Synthesis of Al-Ni-Co-Y Bulk Metallic Glass fabricated by Spark Plasma Sintering (방전 플라즈마 소결법을 이용한 Al-Ni-Co-Y 벌크 비정질 합금의 제조)

  • Jeong Pyo Lee;Jin Kyu Lee
    • Journal of Powder Materials
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2023
  • In this study, an Al82Ni7Co3Y8 (at%) bulk metallic glass is fabricated using gas-atomized Al82Ni7Co3Y8 metallic glass powder and subsequent spark plasma sintering (SPS). The effect of powder size on the consolidation of bulk metallic glass is considered by dividing it into 5 ㎛ or less and 20-45 ㎛. The sintered Al82Ni7Co3Y8 bulk metallic glasses exhibit crystallization behavior and crystallization enthalpy similar to those of the Al82Ni7Co3Y8 powder with 5 ㎛ or less and it is confirmed that no crystallization occurred during the sintering process. From these results, we conclude that the Z-position-controlled spark plasma sintering process, using superplastic deformation by viscous flow in the supercooled liquid-phase region of amorphous powder, is an effective process for manufacturing bulk metallic glass.

Synthesis of Ni-based Bulk Metallic Glass Composites (Ni계 벌크 비정질 복합재의 제조)

  • Lee, Jin-Kyu
    • Journal of Powder Materials
    • /
    • v.15 no.4
    • /
    • pp.297-301
    • /
    • 2008
  • The Ni-based bulk metallic glass matrix composites were fabricated by spark plasma sintering of mixture of gas-atomized metallic glass powders and ductile brass powders. The successful consolidation of metallic glass matrix composite was achieved by strong bonding between metallic glass powders due to viscous flow deformation and lower stress of ductile brass powders in the supercooled liquid state during spark plasma sintering. The composite shows some macroscopic plasticity after yielding, which was obtained by introducing a ductile second brass phase in the Ni-based metallic glass matrix.

Validation of LC-MS/MS Method for Determination of Rabeprazole in Human Plasma : Application of Pharmacokinetics Study (인체 혈장중 라베프라졸의 정량을 위한 LC-MS/MS 분석법 검증 및 단일 용량 투여에 의한 약물동태 연구)

  • Tak, Sung-Kwon;Seo, Ji-Hyung;Ryu, Ju-Hee;Choi, Sang-Joon;Lee, Myung-Jae;Kang, Jong-Min;Lee, Jin-Sung;Hong, Seung-Jae;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.73-78
    • /
    • 2009
  • A simple LC-MS/MS method of rabeprazole in human plasma was developed and validated. Rabeprazole and Internal standard (I.S), omeprazole, were extracted from human plasma by liquid liquid extraction, chromatographic separation of rabaprazole in plasma was achieved at $45^{\circ}C$ with a Shiseido UG120 $C_{18}$ column and methanol-10 mM ammonium acetate buffer (pH 9.42 with ammonium water), as mobile phase. Rabeprazole produced a protonated precursor ion [$(M+H)^+$] at m/z 360.10 and corresponding product ion at m/z 242.21. Internal standard produced a protonated precursor ion [$(M+H)^+$] at 346.09 and corresponding product ion at m/z 198.09. This method showed linear response over the concentration range of $1{\sim}500\;ng/mL$ with correalation coefficient greater than 0.99. The lower limit of quantitation (LLOQ) using 0.2 mL plasma was 1 ng/mL, which was sensitive enough for pharmacokinetics studies. The method was specific and validated with a limit of quantitation of 1 ng/mL. The intra-day and inter-day precision and accuracy were acceptable for all samples including the LLOQ. The applicability of the method was demonstrated by analysis of plasma after administration of a single 10 mg dose to 36 healthy subject. From the plasma rabeprazole concentration versus time curves, the mean $AUC_t$ (The area under the plasma concentration-time curve from time 0 to 12 hr ) was $691.36{\pm}321.88\;ng{\cdot}hr/mL$, $C_{max}$ (maximum plasma drug concentration) of $353.21{\pm}131.52\;ng/mL$ reached $3.4{\pm}1.1\;hr$ after adiministration. The mean biological half-life of rabeprazole was $1.37{\pm}0.75\;hr$. Based on the results, this simple method could readily be used in pharmacokinetics studies.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF