• Title/Summary/Keyword: Liquid line

Search Result 537, Processing Time 0.024 seconds

Effective Smoothness of Surge Pressure Generated in the Return Line of Active Suspension Hydraulic System for Vehicle (자동차 능동 현가장치 유압계 회귀 관로에서의 서지 압력 저감법)

  • 정용길;이일영;윤영환
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.111-118
    • /
    • 1998
  • Surge pressure problem at the oil return line of the hydraulic circuit of an active suspension system for passenger cars was investigated by experiments and numerical analyses. In the numerical analyses, the method of characteristics was used for simulating unsteady flow in the hydraulic system and gas discrete model was adopted for estimating gas volume variation in separated liquid column. In the experiments and analyses, effects of the physical parameters of the accumlator on smoothing surge pressure was elucidated.

  • PDF

Design on SDS2 On-line Poison Concentration Monitoring in CANDU

  • Kim, Seog-Nam;Jung, Ho-Chang;Kim, Sung;Kim, Ji-Hyeon;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.500-505
    • /
    • 1996
  • At the reference plant(Wolsong unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsong unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low.

  • PDF

Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant (정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석)

  • Song K. S.;Oh S. Y.;Park Y. B.
    • Journal of computational fluids engineering
    • /
    • v.7 no.2
    • /
    • pp.1-7
    • /
    • 2002
  • The present study is developed device that effectively mixes raw water and chemicals by using the residual head of fluid in the front pipe of flocculation basin, and performed non-dimensional analysis and presented design standard to apply to water plants that have different equipment capacity. The variables for design are a proper ratio between an outer diameter of deflector and a diameter of pipe, a distance between deflector and orifice and a determination of orifice diameter for an optimal mixing. Numerical study has analyzed flow field on a basis of turbulent intensity in an orifice downstream. As Reynolds number of In-Line Orifice was increased from identical design variable, the turbulent intensity of pipe center was no changed almost.

A Study on the Characteristic of Contactless Power Supply System for Operation Pattern of Stocker System (Stocker 시스템의 동작패턴에 대한 비접촉 전원장치의 특성에 관한 연구)

  • Hwang, Gye-Ho;Lee, Bong-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.23-27
    • /
    • 2011
  • In this paper, material handing cleanroom stocker system for thin film solar cell line of photovoltaic industry and liquid crystal display line of flat panel display industry was selected for the study. Optimum solution for stocker system's CPS(Contactless Power Supply) is approached by changing the motion pattern, optimizing design & production, and analyzing characteristics of the power system. As a result, acceleration time of X-Axis changed from 3 sec to 4 sec, changed the input characteristic of CPS within approximately 11[kW]. This result shows that extending acceleration time of the X-Axis in Stocker Crane's motion pattern can reduce the capacity of the CPS, thus saving the manufacturing cost.

Charge Injection by Needle Electrode and Reduction Properties of Streaming Electrification (침 전극을 이용한 전하 주입과 유동대전 감소 특성)

  • Kim, Yong-Woon;Lee, Duck-Chool;Kang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.108-112
    • /
    • 2000
  • The electric charge generated by flowing insulation liquid can create hazardous spark in transfer line and receiving tank etc. These electrification has generally been measured by current measurement with a ammeter connected to the receiving tank. This paper reports on the experimental result obtained by this method. As a experimental results: The injected charge value for unit volume increased in the following condition, the edge of the needle electrode was sharp, the number of needle electrode was fewer, the edge of the needle electrode was located close to the inside wall. When the charge density in the charge reducer is constant, electrode current and electrode potential by the charge injection from outside increase with increasing of oil velocity and streaming current. The electrode potential in charge reducer is made maximum value at edge point of reducer inside and minimum value at center line of charge reducer.

  • PDF

The Possibility and Risk of Generation of Cavitation at the inlet of the Turbopump (선화제펌프 입구에서 캐비테이션 발생 가능성 및 위험성 평가)

  • Kim, Cheul-Woong;Moon, In-Sang;Bershadskiy, V.A
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.279-282
    • /
    • 2006
  • Upon a turbopump's running, cavitation may occur at the inlet of the LOx pump by pressure drop and heat transfer along the LOx feeding line. Since the cavitation can cause serious damage to the pump or to stop running, the absence of the cavitation at the inlet of a turbopump should be confirmed before the using the turbopump. In the present study, the calculation of the volume fraction of LOx gas phase at the inlet of the pump are performed with different temperatures of LOx in the tank, pressure drops and heat transfers along the feeding line. This calculation method can be applied to define the limits of thermal and hydraulic characteristics during the design of a LOx feeding system.

  • PDF

Development of On-line Portal Imaging System and its Linearity (온라인 방사선 치료 조사야 영상 시스템의 제작과 선형성 조사)

  • 김성환;김재철;박인규
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 1997
  • Verification of patients setup was very important during radiotherapy. Therefore, we have developed an 1-dimensional on-line portal imaging system and measured the differential linearity of the system. Isooctane(2,2,4-TetraMethyl Pentane) was used as liquid ionization material. And the geometry of the system was designed which has 2mm position resolution and 20cm measurable range. And then the differential linearity of the system was 4.7%.

  • PDF

Fabrication and Its Evaluation of the Light-weight Composite Pallet Plank for an Assembly Line of LCD/PDP by using Honeycomb Sandwich Panel (하니컴 샌드위치 Panel을 이용한 LCD/PDP 생산 공정용 경량 고기능성 복합 신소재 파렛트 제조 및 그 특성 평가)

  • Kim, Yun-Hae;Choi, Byung-Geun;Son, Jin-Ho;Jo, Young-Dae;Eum, Soo-Hyun;Woo, Byung-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.304-310
    • /
    • 2006
  • A typical honeycomb sandwich panel consists of two thin, high-strength facings bonded to a thick, light-weight core. Each component by itself is relatively weak and flexible, but when it combined in a sandwich panel they produce a structure that is stiff, strong, and lightweight. To prove the suitability the honeycomb sandwich structure with prepreg, the mechanical properties of the skin materials and honeycomb sandwich structure were evaluated with the static strength tests. Accordingly, the honeycomb sandwich structure made by autoclave process is available for a panel on LCD/PDP assembly line.

Numerical Analysis Study of the Mixing Mechanism of Non-element Mixer (논 엘레멘트 믹서의 혼합 메커니즘에 관한 수치해석적 검토)

  • You, Sun Ho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Visualization of the mixing pattern in a non-element mixer was carried out using laser induced fluorescence(LIF) to evaluate characteristics of mixer consisting of the main flow pipe and branch flow pipes. The branch flows were injected periodically with the period $T_{in}$ normal to the main flow, and rhodamine B was mixed into the most upstream branch flow to visualize mixing pattern in the main flow pipe by LIF. The length of boundary line L of the LIF image was measured. In this study, a numerical analysis was performed to identify the mixing process of the non-element mixer, and the results were compared with experimental results. Each result was almost the same. When the number of branch flows is increased, the mixing pattern became complicated and was supposed to become chaotic. The length of boundary line L increased exponentially with an increase in the number of branch flows.

Charging and Feed-Though Characteristic Simulation of TFT-LCD by Applying Several Driving Method (구동 방법에 따른 TFT-LCD의 충전 및 Feed-Though 특성 시뮬레이션)

  • Park, Jae-Woo;Kim, Tae-Hyung;Noh, Won-Yoel;Choi, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.452-454
    • /
    • 2000
  • In recent years, the Thin Film Transistor Liquid Crystal Display (TFT-LCD) is used in a variety of products as an interfacing device between human and them. Since TFT-LCDs have trend toward larger Panel sizes and higher spatial and/or gray-scale resolution, pixel charging characteristic is very important for the large panel size and high resolution TFT-LCD pixel characteristics. In this paper, both data line precharging method and line time extension (LiTEX) method is applied to Pixel Design Array Simulation Tool (PDAST) and the pixel charging characteristics of TFT-LCD array were simulated, which were compared with the results calculated by both PDAST In which the conventional device model of a-Si TFTs and gate step method is implemented.

  • PDF