• Title/Summary/Keyword: Liquid line

Search Result 535, Processing Time 0.021 seconds

Visualization of Vortex-induced Mixing at the Liquid-liquid-gas 3-phase Contact Line (액체-액체-기체 3상 접촉선에서의 와류에 의한 혼합 가시화)

  • Kim, Tae-Hong;Kim, Hyoungsoo;Kim, Seungho;Kim, Ho-Young
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.21-24
    • /
    • 2012
  • Although the motion of the three-phase contact line on a solid substrate has been extensively studied thus far, the understanding of the dynamics of the contact line of liquid/liquid/gas phases is far from complete. Here we deposit a drop of isopropyl alcohol (IPA) on water and HFE-7100 whose free surfaces are exposed to air to observe the flow field around the contact line. By combining the shadowgraph and high-speed imaging techniques, we find that vortices are spontaneously generated at the contact line, which grow in size with time. The flow is attributed to the Marangoni stress that pulls a liquid of lower-surface tension toward a liquid surface having a higher surface tension. However, it is not still clear why the entrained lower-surface-tension liquid should whirl rapidly beneath the contact line. We also visualize the flow by the particle image velocimetry (PIV) to find out that the rotational velocity reaches the order of 1 mm/s near the free surface.

Bioactivity Analysis of Curcuminoids from Turmeric using On-line Screening HPLC-ABTS (On-line Screening HPLC-ABTS를 이용한 강황으로부터 Curcuminoids의 생물활성 분석)

  • Choi, Sun Do
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.3
    • /
    • pp.137-139
    • /
    • 2013
  • Free radical scavengers in the bisdemethoxycurcumin (BDMC), demethoxycurcumin (DMC) and curcumin of turmeric (Curcuma longa) were screened, identified, quantified and isolation using coupled off-line-2,2'-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid) (ABTS) and on-line screening high-performance liquid chromatography (HPLC)-ABTS assay. There was a very small margin of error between the off-line-ABTS method and the on-line screening HPLC-ABTS method.

Generation of Disclination Line Dependent on Liquid Crystal's Pretilt Angle in Liquid-Crystal-on-Silicon Devices (Liquid-Crystal-on-Silicon 소자에서 액정의 프리틸트각에 따른 Disclination Line 발생)

  • 정태봉;오세태;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • We have studied how surface pretilt angle affects generation of disclination line in liquid-crystal-on silicon cells for 45$^{\circ}$-twisted nematic (TN) and vertical alignment (VA) modes with pixel size of 15$\mu\textrm{m}$. Our studies show that when the pretilt angle is increased from 0$^{\circ}$to 3$^{\circ}$ in the 45$^{\circ}$-TN cell, the disclination line at left side of on-pixel becomes weak and is well suppressed with $\theta$$\_$p/=3$^{\circ}$ although the pixel size Is decreased. In the VA cell, when the pretilt angle is decreased from 89$^{\circ}$ to 86$^{\circ}$, the disclination line at right side of the on-pixel is suppressed well and even for a smaller pixel size, it does not exist when $\theta$$\_$p/=86$^{\circ}$. The results inform that the pretilt angle strongly affects the image quality of microdisplays.

Conceptual Design of Penumatic System Routing for Liquid Rocket Engine (액체로켓엔진의 공압류 라우팅 개념 설계)

  • Kim, Okkoo;Park, Soonyoung;Jung, Eunhwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1112-1114
    • /
    • 2017
  • The liquid rocket engine determines the routing of the component placement and layout by adapted the cycle method, the hardware configuration, the gimbal type on the functional implementation, and so on. In this paper, the conceptual routing of major pneumatic lines such as helium (He) supply pneumatic line for driving, many purge pneumatic line and main ignition line based on the main components installed in the liquid rocket engine was performed.

  • PDF

Binary Vapor-Liquid Equilibria and Ternary Liquid-Liquid Equilibria for NMF Contained Systems (NMF를 포함하는 이성분계의 등온 기-액 평형과 삼성분계 액-액 평형)

  • Park, So-Jin;Han, Kyu-Jin;Won, Dong-Bok;Oh, Jong-Hyeok;Choi, Young-Yoon
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.259-265
    • /
    • 2005
  • Binary isothermal vapor-liquid equilibrium(VLE) data were measured for water+n-methylformamide(NMF), benzene+NMF and toluene+NMF systems by using headspace gas chromatography(HSGC) at 353.15K. Additionally, the ternary liquid-liquid Equilibrium(LLE) data were determined by measuring of tie-line for the systems of NMF+benzene+n-heptane and NMF+toluene+n-heptane at 298.15 K. The measured isothermal binary VLE data have no azeotropes and were correlated well with $g^E$ model equations of Margules, van Laar, Wilson, NRTL and UNIQUAC. The experimental ternary tie line data were also correlated well with NRTL and UNIQUAC models. Besides their accuracy was analyzed by Hirata-Fujita and Maior-Swenson equations.

Liquid Oxygen in Feeding Line during Propellant Filling and Holding (산화제 충진 및 대기 과정의 추진제 공급배관 내부 현상)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Chung, Yong-Gahp;Lee, Joong-Youp
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.34-37
    • /
    • 2007
  • Propellant filling and holding test was carried out using liquid oxygen as a working fluid. The feeding line system has a filter at propellant tank outlet. Vaporization of liquid oxygen during holding after completion of filling and effect of vaporization to recirculation performance in this system was observed. Filling rate and pressure of tank ullage had the effect on state of liquid oxygen in feeding line. There was no geysering in feeding line during holding because of the position of filter.

  • PDF

Study on longitudinal variation of subcooling with high elevated liquid line in a modular heat pump system (모듈형 동시냉난방 열펌프의 장배관/고낙차에 따른 액선 과냉도 변화에 대한 연구)

  • Shin, Kwang-Ho;Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang;Park, Sung-Ryung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1255-1260
    • /
    • 2008
  • This study is simulation of high elevated liquid line of a modular heat pump system to observe longitudinal subcooling variation. In a high elevated tube, subcooled refrigerant(R410A) through a condenser changes its states by heat transfer with surrounding air and by pressure drop from elevation. In this study, the liquid line was simulated through correlations of heat transfer and pressure drop for the variation from single-phase into two-phase flow. Pressure drop, heat transfer rate and vapor quality were calculated as key parameters. Two-phase turning heights and variations of the key parameters were confirmed from the simulation. As a result, high elevation of liquid line has great influence on upward flow, which requires additional equipment to compensate the variation.

  • PDF

Numerical Study of Liquid Film Flow on Heat Exchanger Tube Arrangement and Configuration of Multi Effect Distillation (증발식 다중효용 담수기에서 열교환기 튜브 배열 및 형상에 따른 액막 유동에 관한 수치해석)

  • Jung, Il-Young;Yun, Sang-Kook;Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.68-73
    • /
    • 2011
  • This study was performed numerical analysis in order to analyze liquid film flow of heat exchanger tube arrangement and configuration of evaporative multi effect distillation system using medium-temperature. Simulation was accomplished the two-dimensional calculations using commercial analyses program FLUENT based on the FVM(finite volume method). Fresh water generator of this study used Shell & Tubes heat exchanger with Cu_Ni tube, configuration of tube used bare tube and corrugated tube, and arrangement of tube used in-line array and staggered array. Performance of heat exchanger through the formation of liquid film was compared and analyzed. Liquid film flow occurred that falling on heat exchanger tube wall. Result of simulation showed that liquid film thickness of in-line arrangement was found 0.57mm with bare tube and 0.67mm with corrugated tube, respectively. And liquid film thickness of staggered arrangement was found 0.39mm with bare tubes and 0.62mm with corrugated tubes, respectively. Liquid film thickness of corrugated tube showed thicker than bare tube, but heat transfer rates of corrugated tube showed higher than bare tube. The reason was considered that surface area of corrugated tube was wider than bare tube. And liquid film thickness of staggered arrangement showed thinner than in-line arrangement, so thermal performance of staggered arrangement showed higher than in-line arrangement.

  • PDF

Generation of Disclination Line Dependent on Liquid Crystal′s Rubbing Direction and Voltage Driving Method in Microdisplays (마이크로디스플레이의 액정 러빙 방향과 전압 인가 방식에 따른 Disclination Line의 생성)

  • Jung, Tae-Bong;Song, Je-Hoon;Oh, Sae-Tae;Lee, Seung-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.622-632
    • /
    • 2004
  • We have studied how liquid crystal's rubbing direction and voltage driving method affect generation of disclination line. At first, generation of disclination line in vertical alignment(VA) cell and VA-twisted nematic(TN) cell has been examined. When liquid crystal's rubbing direction of bottom substrate was 0$^{\circ}$, the degree of generated disclination line was the smallest value. Further, the generation of disclination line above the electrode is less in the frame inversion than in the line inversion. Secondly, we have examined a generation of disclination line in reflective fringe-field switching cell. When the distance between common electrodes is over 3 ${\mu}{\textrm}{m}$ with on-state of one pixel and off-state of neighboring pixels, the reflectance appears only on-state pixel without generating reflectance in adjacent pixels.

Computational Analysis of an LOx Supply Line System of an Liquid Rocket Engine (액체로켓엔진 산화제 배관 시스템 전산유동해석)

  • Moon, In-Sang;Moon, Il-Yoon;Lee, Soo-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.693-702
    • /
    • 2009
  • A computational fluid analysis was performed on an LOx line system of a liquid rocket engine. The model was created with 3D CAD and imbedded to the 3D CFD program. Before the full scale analysis on the system was carried out, each components with simplified models was analyzed to save time and cost. As a result, the inlet pressure of the gas generator should be compensated with a certain device unless the inlet pressure of the line system is sufficiently high. The flow pattern of the exit of the system was dependant upon the location of the orifice as well as the size. As a whole the line system analyzed met the requirements, and will be tested and confirmed after being manufactured.