• Title/Summary/Keyword: Liquid in a tank

Search Result 449, Processing Time 0.025 seconds

A Study on Damage Analysis Safety Distance Setting for LPG BLEVE (LPG BLEVE 피해분석 및 안전거리 설정에 관한 연구)

  • Kim, Jonghyuk;Lee, Byeongwoo;Kim, Jungwook;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.25-31
    • /
    • 2020
  • Boiling Liquid Expanding Vapor Explosion(BLEVE) can cause not only economic damage to the plant but also serious casualties. LPG accidents account for 89.6 percent of all accidents caused by gas leaks in Korea over the past nine years, while casualties from accidents also account for 73 percent of all accidents, according to statistics from the Korea Gas Safety Corporation. In addition, a potential explosion and a fire accident from one LPG storage tank may affect the nearby storage tanks, causing secondary and tertiary damage (domino effect). The safety distance standards for LPG used by LPG workplaces, charging stations, and homes in Korea have become stricter following the explosion of LPG charging stations in Bucheon. The safety distance regulation is divided into regulations based on the distance damage and the risk including frequency. This study suggests two approaches to optimizing the safety distance based on the just consequence and risk including frequencies. Using the Phast 7.2 Risk Assessment software by DNV GL, the explosion overpressure and heat radiation were derived according to the distance caused by BLEVE in the worst-case scenario, and accident and damage probability were derived by considering the probit function and domino effect. In addition, the safety distance between LPG tanks or LPG charging stations was derived to minimize damage effects by utilizing these measures.

Methanol Extraction of Nitrogen Heterocyclic Compound Contained in Model Coal Tar Fraction of Nine Components System (9성분계 모델 콜타르 흡수유 중에 함유된 질소고리화합물의 메탄올 추출)

  • Kim, Su Jin;Kang, Ho Cheol
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.142-146
    • /
    • 2014
  • The separation of nitrogen heterocyclic compound (NHC) contained in a model coal tar fraction of nine components system was investigated by distribution equilibrium. The model coal tar fraction comprising NHC group (NHCs; indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine(Qu)), bicyclic aromatic compound group (BACs; 1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN)), biphenyl (Bp) and phenyl ether (Pe) and the aqueous methanol were used as the raw materials and the solvent of this work, respectively. A batch-stirred tank was used as the liquid-liquid contact unit of this work. The distribution coefficient of NHCs increased by increasing the equilibrium operation temperature, whereas the selectivity of NHCs with respect to BACs decreased. Decreasing the initial volume ratio of water to the solvent resulted in deteriorating the selectivity of NHCs in reference to BACs, but improving the distribution coefficients of NHCs. At a fixed experimental condition, the sequence of the distribution coefficient and the selectivity with reference to BACs for each groups was increased in order of NHCs > Bp > BACs > Pe and NHCs > Bp> Pe, respectively. Also, the sequence of the distribution coefficient for entire compounds was in order of In > iQ = Q > Qu > Bp > 1MN = 2MN > Pe > DMN. The maximum yield of NHCs and the selectivity of NHCs based on BACs obtained by methanol extraction were 94 and 23%, respectively. Furthermore, the recovery process for NHCs from coal tar was studied by using the experimental results from this work.

A Study on Reliability Analysis and Quantitative Risk Analysis for Liquefied Petroleum Gas Station (LPG 충전시설에 대한 신뢰도 분석과 정량적 위험성 분석에 관한 연구)

  • Kim In-Won;Jin Sang-Hwa;Kim Tea-Woo;Kim In-Tae;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.40-48
    • /
    • 2001
  • For a Liquified Petroleum Gas(LPG) station, the reliability analysis, such as Fussell-Vesely importance, risk decrease factor and risk increase factor, was carried out and the risk ranks of events were determined. In order to confirm the degree of the risks identified in the reliability analysis, the quantitative risk analysis was done for the equipments which had the large values of risk ranks. As a result of the importance analysis for the LPG station, the external event was identified as the most riskful event. The defect of construction structure and the pipe corrosion were riskful as well. The result of quantitative risk analysis showed that the length of 46.3 meters were estimated to damage the process equipments by the thermal flux from the catastrophic rupture of storage tank in Boiling Liquid Expanding Vapor Explosion.

  • PDF

Studies on the Sorption and Fixation of Cesium by Vermiculite

  • Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.310-320
    • /
    • 1973
  • The sorption and fixation of cesium in dilute solutions by vermiculite saturated with Na or K were studied in order to investigate any possibibty of its use in radioactive effluent treatment. The cesium sorbed by vermiculite with the increase in pH is attributed to the increase of sorption surface as a result of the dispersion. The increased cesium sorption by Na-vermiculite is due to the different sorption rates by the different exchange sites : external surface and internal surface. It is shown that the larger amount of sorbed cesium was extracted by KCI rather than with any other extractants. It is suggested that the fixation of cesium by vermiculite occurs at the crystal edge where Cs may replace K. Domestic vermiculite is a valuable material for use in the cesium sorption and fixation, and might be useful as a good packing material outside the tank of highly radioactive liquid waste. And from these results one could suggest that the artificial alteration of the biotite to vermiculite might be occurring by treating with NaCl.

  • PDF

APPLICATION OF 3D TERRAIN MODEL FOR INDUSTRY DISASTER ASSESSMENT

  • Kim, Hyung-Seok;Cho, Hyoung-Ki;Chang, Eun-Mi;Kim, In-Hyun;Kim, In-Won
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.3-5
    • /
    • 2008
  • An increase in oil and gas plants caused by development of process industry have brought into the increase in use of flammable and toxic materials in the complex process under high temperature and pressure. There is always possibility of fire and explosion of dangerous chemicals, which exist as raw materials, intermediates, and finished goods whether used or stored in the industrial plants. Since there is the need of efforts on disaster damage reduction or mitigation process, we have been conducting a research to relate explosion model on the background of real 3D terrain model. By predicting the extent of damage caused by recent disasters, we will be able to improve efficiency of recovery and, sure, to take preventive measure and emergency counterplan in response to unprepared disaster. For disaster damage prediction, it is general to conduct quantitative risk assessment, using engineering model for environmental description of the target area. There are different engineering models, according to type of disaster, to be used for industry disaster such as UVCE (Unconfined Vapour Cloud Explosion), BLEVE (Boiling Liquid Evaporation Vapour Explosion), Fireball and so on, among them, we estimate explosion damage through UVCE model which is used in the event of explosion of high frequency and severe damage. When flammable gas in a tank is released to the air, firing it brings about explosion, then we can assess the effect of explosion. As 3D terrain information data is utilized to predict and estimate the extent of damage for each human and material. 3D terrain data with synthetic environment (SEDRIS) gives us more accurate damage prediction for industrial disaster and this research will show appropriate prediction results.

  • PDF

3D Terrain Model Application for Explosion Assessment

  • Kim, Hyung-Seok;Chang, Eun-Mi;Kim, In-Won
    • 한국지역지리학회:학술대회
    • /
    • 2009.08a
    • /
    • pp.108-115
    • /
    • 2009
  • An increase in oil and gas plants caused by development of process industry have brought into the increase in use of flammable and toxic materials in the complex process under high temperature and pressure. There is always possibility of fire and explosion of dangerous chemicals, which exist as raw materials, intermediates, and finished goods whether used or stored in the industrial plants. Since there is the need of efforts on disaster damage reduction or mitigation process, we have been conducting a research to relate explosion model on the background of real 3D terrain model. By predicting the extent of damage caused by recent disasters, we will be able to improve efficiency of recovery and, sure, to take preventive measure and emergency counterplan in response to unprepared disaster. For disaster damage prediction, it is general to conduct quantitative risk assessment, using engineering model for environmentaldescription of the target area. There are different engineering models, according to type of disaster, to be used for industry disaster such as UVCE (Unconfined Vapor Cloud Explosion), BLEVE (Boiling Liquid Evaporation Vapor Explosion), Fireball and so on, among them.we estimate explosion damage through UVCE model which is used in the event of explosion of high frequency and severe damage. When flammable gas in a tank is released to the air, firing it brings about explosion, then we can assess the effect of explosion. As 3D terrain information data is utilized to predict and estimate the extent of damage for each human and material. 3D terrain data with synthetic environment (SEDRIS) gives us more accurate damage prediction for industrial disaster and this research will show appropriate prediction results.

  • PDF

A STUDY ON THE PRESSURE BEHAVIOR INSIDE PROPELLANT LINE OF SATELLITE (인공위성 연료배관의 유압특성 연구)

  • Choi, Jin-Chul;Kim, Jeong-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.3
    • /
    • pp.207-214
    • /
    • 2002
  • One of the way to derive design parameters of the fuel feeding system in satellite propulsion system is to analyze unsteady flow of liquid propellant (hydrazine). During steady thruster firing the flow rate is constant: if a thruster valve is abruptly shut down among a set of thrusters, pressure spikes much higher than the initial tank pressure occur. This renders the fuel flow unsteady, and the fluid pressure and flow rate to oscillate. If the pressure spikes are high enough, there are possibilities that propellant explosively decomposes, thruster valves we damaged, and adiabatic detonation of the hydrazine propellant is potentially incurred. Reflected shockwaves could also affect the calibration and operation of the pressure transducers. These necessitate the analysis of unsteady flow in the propulsion system design, and pressure behavior inside the propellant line obtained through some governing parameter variation is presented in this work.

Analysis of operating characteristics and design review of oxidizer fill-drain valve (산화제 충전/배출 밸브의 설계 검토 및 작동 특성 분석)

  • Jang, Je-Sun;Kwon, Oh-Sung;Lee, Kyung-Won;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.79-88
    • /
    • 2011
  • A fill-drain valve is operated by provided control gas at the ground for liquid propellant feeding system of space launch vehicle, which fills or drains on-board propellant tanks with a cryogenic oxidizer. We have analyzed and modified the data of fill-drain valve designed by Yuzhnoye. The simulation model of fill-drain valve is designed by using the AMESim code to predict and evaluate the dynamic characteristics and pneumatic behavior of valve. In this study, we performed a dynamic characteristic simulation on design parameter. And we could predict opening/closing time and pressures, operating performances on design parameters. This study will serve as one of reference guides to enhance the developmental efficiency of fill-drain valves with the various operating requirements, which shall be used in the Koreanized Space Launch Vehicle.

A Study on Synthetic Method and Material Analysis of Calcium Ammine Chloride as Ammonia Transport Materials for Solid SCR (Solid SCR용 암모니아 저장물질인 Calcium Ammine Chloride의 합성방법 및 물질분석 연구)

  • Shin, Jong Kook;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.199-207
    • /
    • 2015
  • Solid materials of ammonia sources with SCR have been considered for the application of lean NOx reduction in automobile industry, to overcome complex problems of liquid urea based SCR. These solid materials produce ammonia gas directly with proper heating and can be packaged by compact size, because of high volumetric ammonia density. Among ammonium salts and metal ammine chlorides, calcium ammine chloride was focused on this paper due to low decomposition temperature. In order to make calcium ammine chloride in lab-scale, simple reactor and glove box was designed and built with ammonium gas tank, regulator, and sensors. Basic test conditions of charging ammonia gas to anhydrous calcium chloride are chosen from equilibrium vapor pressure by Van't Hoff plot based on thermodynamic properties of materials. Synthetic method of calcium ammine chloride were studied for different durations, temperatures, and pressures with proper ammonia gas charged, as a respect of ammonia gas adsorption rate(%) from simple weight calculations which were confirmed by IC. Also, lab-made calcium ammine chloride were analyzed by TGA and DSC to clarify decomposition step in the equations of chemical reaction. To understand material characteristics for lab-made calcium ammine chloride, DA, XRD and FT-IR analysis were performed with published data of literature. From analytical results, water content in lab-made calcium ammine chloride can be discovered and new test procedures of water removal were proposed.

A Study on the Condensation Prevention of Bulk Carrier (화물선의 결로 방지에 대한 연구)

  • Oh, Sae-Gin;Kim, Won-Ouk;Kim, Seung-Hwan;Lee, Seung-Geun;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.429-434
    • /
    • 2011
  • Bulk cargo loaded into ship can be damaged by various kinds reasons. This paper aims to analyze about cargo damage of coil carrier ship due to condensation. Condensation is the formation of liquid drops of water from water vapor. Condensation consists of small drops of water which form when warm water vapour or steam touches a cold surface such as a window. In general, condensation have occurred by temperature difference at large building and ship's tank. It is phenomenon that can occur often to oceangoing vessel moving temperature difference places in similar time. This paper proposes a new method using dehumidification device and fan heater to prevent bulk cargo damage of coil carrier ship from condensation.