• 제목/요약/키워드: Liquid breakdown

검색결과 175건 처리시간 0.033초

고온초전도 기기의 신뢰성 확보를 위한 고려한 절연재료의 수명 특성 연구 (A Study on Life Characteristics of Insulator for Stability of a HTS equipment)

  • 백승명;김현희;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.965-966
    • /
    • 2007
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of insulators in cryogenic liquid such as liquid nitrogen ($LN_2$) is essential. So in this paper, we discussed experimental investigations of breakdown and V-t characteristics of several insulators such as Kapton and glass fiber reinforced plastic (GFRP) that are candidates of insulator for HTS apparatus in cryogenic liquid. And we investigated the degradation of these insulation samples after breakdown with the microscope and SEM photograph. Moreover, survival and hazard analysis was performed.

  • PDF

Insulation Characteristics of the Model Cable for 22.9 kV Class HTS Power Cable

  • Kim, Hae-Jong;Seong, Ki-Chul;Cho, Jeon-Wook;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Sang-Hyun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.542-543
    • /
    • 2005
  • In this paper, describes the fabrication and dielectric insulation characteristics experimental results of the model cable for the 22.9kV class HTS power cable. The model cable were tested with partial discharge(PD), AC and impulse withstand voltage in liquid nitrogen($LN_2$) and liquid nitrogen pressure. In these test results, PD inception stress and AC, impulse breakdown strength increase as the pressure of the liquid nitrogen increases.

  • PDF

LSR 계면의 접착특성 및 절연파괴거동 (Adhesion properties and Breakdown behaviors of LSR Interface)

  • 윤승훈;남진호;이건주;최수걸;신두성;지응서
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.232-235
    • /
    • 2002
  • Recently developed liquid silicone rubber (LSR) can be cured by platinum catalyzed additional hydrosilylation mechanism and has the advantage of no byproduct compared to traditional millable peroxide curing silicone rubber. We investigated the characteristics of dielectric breakdown of silicone rubber and adhesion properties between semi-conductive LSR and insulating LSR for high voltage application of pre-molded joint (PMJ). In order to understand the dielectric breakdown characteristics, we used the sheet samples and the paired type rogowski insert electrode system. The breakdown strength and adhesion strength of LSR (E-3) were superior to those of several silicone rubbers. Adhesion strength could be improved by curing at high temperature without post-curing process or enhanced by post-curing process. When LSR (E-3) was cured at $(150^{\circ}C{\times}10min$ semi-conductive )${\times}$ ($175^{\circ}C{\times}10min$ insulation), it showed the high breakdown strength with low standard deviation, and good adhesion strength. In this results, we could apply this process to the fabrication of PMJ without post-curing.

  • PDF

광유의 절연파괴에 미치는 전극간격 및 침전극 곡률반경의 영향 (The Effects of Gap Length and Tip Radius Influenced in Breakdown of Mineral Based Insulating Oil)

  • 이종섭;신태수;이운용;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.254-257
    • /
    • 1997
  • In this paper, we investigated the effects of gap length and tip radius influenced in breakdown of mineral based insulation oil Electrode system was needle-plane geometry It is to model conductive extrusions in oil filled electrical power apparatus. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}{\textrm}{m}$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. It was calculated electrical breakdown strength at tip using Mason\`s equation from breakdown voltage As gap lenght increased. breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by tole phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage. breakdown 7tr7ilgtll was higher wheal polarity of needle was negative than positive. It is because of the space charge effect ill accordance with the influence of liquid motion.

  • PDF

전기절연유의 절연파괴에 미치는 전극간격 및 곡률반경의 영향 (The Influence of Gap Length and Tip Radius on Breakdown of Electrical Insulating Oil)

  • 강성화;채홍인;이종필;임기조
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.56-59
    • /
    • 2004
  • In this paper, we investigated the influence of gap length and tip radius on breakdown of mineral based insulation oil. Applied voltages were DC and AC voltage. Electrode system was needle-plane structure. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}m$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. Electric breakdown strength at tip was calculated using Mason's equation contained geometric figure. As gap length increased, breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by the phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage, breakdown strength was higher when polarity of needle was negative than positive. It is because of the space charge effect in accordance with the influence of liquid motion.

저항형 고온초전도 한류기용 절연체의 절연 특성 (Breakdown Characteristics of Insulators for a Resistor Type HTS Fault Current Limiter)

  • 백승명;류엔반둥;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.48-52
    • /
    • 2004
  • Breakdown characteristics of insulator-liquid nitrogen ($LN_2$) composite insulation for resistor type High $T_c$/ superconducting fault current limiter (HTSFCL) under ac and impulse voltage in $LN_2$ has been studied using model electrode systems. Electrodes for model electrode systems were made of SUS 304 contacted fiberglass reinforced plastic (FRP) and Au coated sapphire. The breakdown characteristics of model electrode systems were investigated experimentally for FRP thickness ranging from 1 mm to 5 mm. surface distance ranging from 2.5 mm to 7 mm and electrode gap ranging from 1 to 5 mm. The experimental data suggested that the breakdown voltage of model electrode systems in $LN_2$ is highly dependent on the surface distance, electrode gap as well as on the FRP thickness. Also, we had observed discharge traces and puncture due to high-voltage 60-Hz AC stress.

고온초전도 변압기를 위한 액체질소 중 절연 파괴, V-t. 열화 특성 (Breakdown, V-t and Degradation Characteristics of Insulation in Liquid Nitrogen for HTS Transformer)

  • Nguyen, Van-Dung;Joung, Jong-Man;Baek, Seung-Myeong;Lee, Chang-Hwa;Suck, Song-Hee;Kim, Sang-Hyun
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.316-323
    • /
    • 2004
  • HTS transformer is one of the most promising devices to supply enough electric energy for quick increase consumption. However, for practical design of the HTS transformer, it is necessary to establish the research on breakdown, V-t characteristics, degradation, and so on. In this paper, we discussed breakdown characteristics and V-t characteristics of polyimide/L$N_2$ and glass fiber reinforced plastic/$LN_2$ composite insulations. These composite insulations have been used as turn-to-turn and layer-to-layer insulations for HTS transformer respectively, Moreover, we investigated the degradation of these insulation samples after breakdown using microscope and SEM photograph.

Breakdown Characteristics of Insulation Materials for a Termination of Power Transmission Class HTS Cable

  • Kwag Dong-Soon;Cheon Hyeon-Gweon;Choi Jae-Hyeong;Kim Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.37-42
    • /
    • 2006
  • A research on several characteristics such as volume breakdown and surface discharge of insulators for a termination of power transmission class HTS cable was performed. We investigated the surface discharge of glass fiber reinforced plastic (GFRP) under air, cryogenic nitrogen gas and nitrogen gas media. The breakdown characteristics of these media were studied. Experimental results revealed that flashover voltage greatly depends on pressure, temperature, the kinds of insulating media and voltages, but it is slightly affected by shape and material of electrode. The breakdown voltage of liquid nitrogen, cryogenic nitrogen gas and nitrogen gas deeply depends on the shape and dimension of electrode, kinds of voltages and pressure. Moreover, the breakdown voltage of cryogenic nitrogen gas and flashover voltage of GFRP in the cryogenic nitrogen gas is also influenced by temperature and vapour-mist density of the gas.

액체 이산화탄소 파쇄법의 파쇄 압력, 음향 방출, 균열 형상에 관한 실험적 연구 (Experimental Study of Breakdown Pressure, Acoustic Emission, and Crack Morphology in Liquid CO2 Fracturing)

  • 하성준;윤태섭
    • 터널과지하공간
    • /
    • 제29권3호
    • /
    • pp.157-171
    • /
    • 2019
  • 액체 이산화탄소 파쇄법은 기존 수압 파쇄법에서 물 사용으로 발생하는 환경 문제를 완화시키기 위한 차세대 해결책으로 제안되어 왔으며, 액체 이산화탄소의 낮은 점성도를 이용하여 암석 공극 내 유체 주입을 수월하게 할 수 있다. 본 연구에서는 액체 이산화탄소의 공극 내 주입이 파쇄 과정 중에 발생하는 파쇄 압력, 음향 방출, 균열 형상에 어떻게 영향을 미치는지에 대해 초점을 맞추었다. 이를 위해 점성도가 다른 액체 이산화탄소, 물, 오일을 파쇄 유체로 사용하여 주입 속도를 다르게 하며 인공적으로 제작한 다공성 모르타르 시편을 대상으로 실내실험을 수행하였다. 또한 기존 수압 파쇄법의 주 대상 암종인 셰일 시편의 실험에서 액체 이산화탄소 파쇄법에 의한 셰일의 파괴 특징들을 분석하였다. 실험 결과 이산화탄소 주입 시 균열이 더 비틀린 물결 형상을 띄었으며 특히, 셰일 시편에서는 그 균열 부피가 물 주입에 비해 더 발달하였다. 반면, 파쇄 유체와 파쇄 압력의 관계는 두 시편의 실험에서 반대의 경향을 보였다.

고온초전도 기기를 위한 극저온 액체 중 절연물의 전기적 특성 (Electrical Insulation Characteristics of Insulators in Cryogenic Liquid for a HTS Apparatus)

  • 백승명;곽동순;천현권;최재형;김상현;김현희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.263-264
    • /
    • 2006
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of insulators in cryogenic liquid such as liquid nitrogen ($LN_2$) is essential. So in this paper, we discussed experimental investigations of breakdown and V-t characteristics of several insulators such as Kapton and glass fiber reinforced plastic (GFRP) that are candidates of insulator for HTS apparatus in cryogenic liquid. And we investigated the degradation of these insulation samples after breakdown with the microscope and SEM photograph. Moreover, survival and hazard analysis were performed.

  • PDF