• 제목/요약/키워드: Liquid back

검색결과 261건 처리시간 0.024초

역 브레이튼 냉동사이클을 이용한 LNG 운반선의 증발기체 재액화 시스템에 관한 연구 (A Study on the BOG Re-liquefaction System based on the Reverse Brayton Refrigeration Cycle for LNG Carriers)

  • 진영욱
    • 대한안전경영과학회지
    • /
    • 제9권4호
    • /
    • pp.149-154
    • /
    • 2007
  • The LNG carriers have been propelled by steam turbines and the LNG boil-off(BOG) has been used as fuel or vented. However, as the alternative propulsion systems such as diesel engines are being equipped on the LNG carriers for better fuel efficiency, a need for the LNG BOG re-liquefaction system that liquefies the BOG and sends the liquid BOG back to the LNG cargo has arisen in recent years. This study investigates the design of the BOG re-liquefaction system based on the reverse Brayton refrigeration cycle. The thermodynamic and heat exchanger analysis are carried out and the limitations to the system performance are discussed.

HPLC를 이용(利用)한 제제중(製劑中) 프레드니솔론의 함량균일성시험(含量均一性試驗)에 관한 연구(硏究) (Determination of Prednisolone in Tablets by High Performance Liquid Chromatography)

  • 김형국;이철규;고건일;김재백
    • Journal of Pharmaceutical Investigation
    • /
    • 제13권2호
    • /
    • pp.59-65
    • /
    • 1983
  • A convenient high performance liquid chromatographic method for the quantitative determination and content uniformity of prednisolone in tablets is described. The prednisolone was chromatographed using a ${\mu}-Bondapak\;C_{18}$ column and the eluent 70% MeOH at a flow rate 1. 0ml/min. Diethylstilbestrol was used as an internal standard. The UV detector response at 254nm was linear over a range of $10{\sim}60{\mu}g/ml$ under conditions of the analysis. Reproducibility studies gave relative standard deviations of $0.3{\sim}0.5%$.

  • PDF

전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구 (A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System)

  • 장세호;안수길
    • 동력기계공학회지
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

역대향류 열교환기의 열 핀치(thermal pinch)에 관한 연구 (A Study on the thermal pinch problem in the counterflow heat exchanger)

  • 최성은;진영욱
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2008년도 추계학술대회
    • /
    • pp.659-667
    • /
    • 2008
  • The LNG carriers have been propelled by steam turbines and the LNG boil-off(BOG) has been used as fuel or vented. However, as the alternative propulsion systems such as diesel engines are being equipped on the LNG carriers for better fuel efficiency, a need for the LNG BOG re-liquefaction system that liquefies the BOG and sends the liquid BOG back to the LNG cargo has arisen in recent years. This study investigates the design of the BOG re-liquefaction system based on the reverse Brayton refrigeration cycle. The thermodynamic and heat exchanger analysis are carried out and the limitations to the system performance are discussed.

  • PDF

Determination of carvedilol in human plasma by high-performance liquid chromatography

  • Lee, Jung-Ae;Lee, Ye-Rie;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.220.1-220.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method for the determination of carvedilol in human plasma was developed and validated. Analytes were separated on a XTerra C18 column with acetonitrile-methanol-30 mM KH$_2$PO$_4$ (pH 2.5) (20 : 20 : 60, v/v/v), as mobile phase. One mL plasma were pipetted into glass tubes and spiked with 0.05 mL of internal standard solution. After adding 7 mL of diethyl ether, the plasma sample was then shacked for 15 min. A centrifuged upper layer was back-extracted with 150 uL of 0.05 M sulfuric acid. (omitted)

  • PDF

액체 질소중에서 고체 Spacer에 의한 연면 방전특성 (Characteristics of Surface Flashover of spacer in Liquid Nitrogen)

  • 김영석;백승명;이병성;장현만;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.912-914
    • /
    • 1999
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconducting power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen($LN_2$). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in $LN_2$, and last step is comparison the result of this research with that of fully immersed in $LN_2$ and at cryogenic temperature gaseous nitrogen($GN_2$). This result presented that surface flashover voltage along solid spacer half immersed in $LN_2$ was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10 mm. In the case of t>10 mm, however, spacer flashover voltage was equal to that obtained in $GN_2$ at cryogenic temperature.

  • PDF

컬럼 스위칭 고속액체크로마토그라프법을 이용한 혈장 중 플루코나졸의 분석 (Column-switching High Performance Liquid Chromatographic Determination of Fluconazole in Human Plasma)

  • 지준필;진숙;이미경;김양배;김종국
    • Journal of Pharmaceutical Investigation
    • /
    • 제30권1호
    • /
    • pp.51-54
    • /
    • 2000
  • A column-switching high performance liquid chromatographic method has been developed for the determination of a fluconazole in human plasma. Each plasma sample was centrifuged for 10 min at 5000 g. After an aliqout of the supernatant was taken to nylon microcentrifuge filter, these samples were centrifuged for 10 min at 5000 g. An aliqout of the supernatant was injected directly onto the HPLC column. Deionized water was run for 2 min at a flow rate of 1.0 ml/min to retain fluconazole in an extration column, while proteins and endogenous interferences were eluted to the waste. The analyte was then back-flushed onto an analytical column, $C_{18}$ reversed-phase column. The mobile phase for analytical column, 0.01 M sodium acetate (pH 5.0)-methanol (65:35, v/v), was run at a flow rate of 1.0 ml/min. The column effluent was monitored by ultraviolet detection at 261 nm. The retention time for fluconazole was 11.76 min in human plasma. The detection limit for fluconazole in human plasma was $0.2\;{\mu}g/ml$. No interference from endogenous substances was observed.

  • PDF

동작 전류에 의한 Magnetic fluid Linear Pump의 동특성 해석 (Analysis of the Driving Characteristics in the Magnetic Fluid Linear Pump by Operating Current)

  • 서강;박관수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.237-246
    • /
    • 2004
  • The advantages of the Magnetic Fluid Linear Pump(MFLP) is that this device could Pump the non-conductive. non-magnetic liquid such as Insulin or blood because of the segregation structure of the magnetic fluid and pumping liquid. In this device. the sequential currents are needed to Produce pumping forces so that Pumping Forces and Pumping speed mainly depend on the current Patterns. The excessive forces at Pumping moment could cause the medical shock, and weak forces at intermediate moment could cause the back flow or the pumping liquid. So the ripples of the pumping forces need to be reduced for the medical application. In this research, the driving characteristics in the MFLP by operating current is analysed. The change of magnetic fluid surface according to the driving currents could be obtained be magneto-hydrodynamic analysis so that Pumping fortes could be computed by integration of the surface moving to the pumping direction at each moment. The actual MFLP with 13mm diameter was made and tested for experiments. The effects of driving current and frequency on the pumping forces and pumping speed were analyzed and compared with experimental measurements.

노즐 특성에 따른 전기수력학적 단분산 미립화 효과에 관한 실험적 연구 (An Experimental Study on the Effect of Electrohydrodynamic Monodisperse Atomization According to Nozzle Characteristics)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제10권2호
    • /
    • pp.18-31
    • /
    • 2005
  • This study was performed to explore the liquid breakup and atomization characteristics for the classification of drop formation mode and background of uniform droplets generation in electrohydrodynmaic atomization according to the change of experimental parameters such as nozzle material (stainless steel. teflon). fluid flow rate, applied electrical field and intensity, and frequency. In results, from the classification map of drop formation modes according to the variation of applied AC voltage and frequency at a stainless nozzle, the droplet size was smaller than the outer diameter of the nozzle tip relatively in the spindle mode. The transition points became clearly to be moved toward the high applied voltage by rising the applied AC frequency beyond 450Hz. Also the droplet radius can be observed quite small in the frequency bandwidth of $350{\sim}450Hz$. The droplet radiuses decrease as the applied voltage increases for a fixed applied AC frequency within the range from 50Hz to 400Hz Over 400Hz, the relation between the power intensity and the droplet size was not consistent with a continuous mechanism of liquid breakup. Thus, it is showed that the droplet size distribution using the teflon nozzle was analogous to the results of stainless steel, but the droplet size was bigger than that of stainless steel relatively in case of a teflon nozzle.

  • PDF

마이크로 캡슐 잠열재 슬러리를 적용한 미소채널 열교환기의 열분배 성능평가 (Experimental Study on the Heat Distribution in the Rectangular Mini Channel Heat Exchangers with MPCM Slurry)

  • 전종욱;백창현;김용찬;김영득;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.645-650
    • /
    • 2006
  • The heat transfer performance and energy transport ability are relatively high due to higher specific heat. Therefore, it can be used in fields such as heating, ventilating, air-conditioning, refrigeration and heat exchangers. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, liquid-cooling heat exchangers were tested to provide performance data for MPCM slurry. The liquid-cooling heat exchangers had twelve rectangular channels with flow paths of 1, 2, 4 and 12. Silicon rubber heaters were used to control the heat load to the heat exchanger. Heat input ranged from 293 to 800 W, and inlet temperatures of working fluid varied from 15S to $27^{\circ}C$. The standard deviation of surface temperature was strongly affected by the coolant of MPCM Slurry, All MPCM-cooling heat exchangers showed higher cooling performance than the water-cooling heat exchanger except one path channel heat exchanger.

  • PDF