• Title/Summary/Keyword: Liquid air

Search Result 1,742, Processing Time 0.025 seconds

Development of An Engine Modeling and an Engine Control Module for an LPG Engine (LPG 엔진 모델링 및 ECM 설계에 관한 연구)

  • 심한섭;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.1-9
    • /
    • 1999
  • Liquid Petroleum Gas (LPG) has been widely used for commercial light-duty vehicles worldwide. Since LPG has a higher octane number and a lower maximum combustion temperature than gasoline , it becomes more popular fuel for reducing exhaust emissions. In tihs study, mathematical models of air intake and fuel delivery system are presented, and a PI-controller is designed for air-fuel ratio control. Hardware and software of an engine control module (ECM) are designed for an LPG engine. The ECM is built using a Motorola MC68HC05. In order to control the air-fuel ratio at stoichiometry, the PI-control algorithm is implemented in the ECM. The experiment results show the proto LPG ECM and its control scheme perform well to meet the stoichiometric air-duel ratio requirement.

  • PDF

Spray and Atomization Technologies in Pesticides Application: A Review

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.6 no.4
    • /
    • pp.1-13
    • /
    • 2001
  • In the pesticides sprays, spray and atomization technologies to increase the deposition and reduce the drift are briefly reviewed. Further research is needed to deduce a measure of drift risk in sprays with different structures, velocity profiles. For flat fan nozzles, the data of breakup length and thickness of liquid sheet are essential to understand the atomization processes and develop the transport model to target. In the air-assisted spray technology to reduce drift, further works on the effect of application height on drift and air assistance on droplet size should be followed. In addition, methods for quantifying included air in the air inclusion techniques are required. A few researches on the droplet size of fallout can be found in the literature. A combined technology with electrostatic method into one of method for the reduction of drift may be an effective strategy for increasing deposition and reducing drift.

  • PDF

An Experimental Study on Structure of Twin-Fluid Spray with Air Entrainment (공기 유입을 고려한 2유체 분무의 구조에 관한 실험적 연구)

  • Chae, Hyo-Cheol;Kim, Dong-Il;Oh, Sang-Heun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.925-930
    • /
    • 2000
  • This paper is investigated the entrainment of air into sprays which has significant effects on the combustion efficiency, stability of flame using the air-assisted twin-fluid nozzle in non-burning. The factors which may be expected to affect the entrainment of air by a liquid spray are: Relative velocity of droplet and ambient gas; Drop size and size distribution; Density and other property of the liquid. Here, axial, radial velocity and turbulent kinetic energy of spray droplet was measured with the PIV(Particle Image Velocimetry). Spray characteristics were also visualized using CCD camera. The results indicate that the entrainment rate increases more or less non-linearly with the downstream region.

  • PDF

Research on Step-Type Chemical Liquid Deodorizer using Liquid Catalyst

  • WOO, Hyun-Jin;KWON, Lee-Seung;JUNG, Min-Jae;YEO, Og-Gyu;KIM, Young-Do;KWON, Woo-Taeg
    • The Korean Journal of Food & Health Convergence
    • /
    • v.6 no.5
    • /
    • pp.19-25
    • /
    • 2020
  • The purpose of this study was to research and develop a step-type chemical liquid deodorizer including a liquid catalyst that can prevent civil complaints due to odor due to its excellent deodorizing performance. The main composition of chemical liquid deodorizer including liquid catalyst is cleaning deodorization, catalyst deodorization, chemical deodorization, water film plate, deodorization water circulation device, deodorization water injection device, catalyst management system, gas-liquid separation device, chemical supply device, deodorizer control panel, etc. It consists of a device. The air flow of the step-type liquid catalyst chemical liquid deodorizer is a technology that firstly removes basic odor substances, and the liquid catalyst installed in the subsequent process stably removes sulfur compounds, which are acidic odor substances, to discharge clean air. The efficiency of treating the complex odor of the prototype was 98.5% for the first and 99.6% for the second, achieving the target of 95%. The hydrogen sulfide treatment efficiency of the prototype was 100% for the first and 99.9% for the second, which achieved 95%, which was the target of the project. As a result, ammonia was removed by the reaction of ammonia and hydrogen sulfide.

Effect of Aeration Mechanism on Livestock Manure Liquid Fertilization (폭기형태가 돈분뇨 액비 부숙특성에 미치는 영향)

  • Jeong, Kwang-Hwa;Khan, Modabber Ahmed;Kim, Chang-Hyun;Lee, Dong-Hyun;Choi, Dong-Yoon;Yu, Yong-Hee
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.4
    • /
    • pp.703-713
    • /
    • 2012
  • Three types of aeration system were installed in experimental liquid fertilization tanks to investigate the change of characteristics of pig slurry used as a raw material for making livestock liquid fertilizer. The aeration systems of the reaction tanks were composed of three major part: the air suppling part (blower), the air pipe part, and the air diffuser part. In the first tank (reactor A), the air was supplied from the bottom of the reaction tank through air pipe system connecting air diffuser with commercial ordinary blower. In the second tank (reactor B), the air diffuser was located 10cm above the bottom of the reactor. In the third tank (reactor C), the pure air was supplied with circulating pjg slurry. The oxygen content of pure air was about 90%. The pure air was mixed with pig slurry by mechanically in the air suppling part (blower) and the air pipe part. The agitation effect was highest in the reactor C than other reactors. The contents of SS, COD, T-N and T-P of each samples collected at middle part of all reactors were 8,500, 4,188, 694 and 422mg/L; 9,000, 4,247, 813 and 356mg/L; 8,667, 6,910, 973 and 269mg/L, respectively.

Experimental Study of the Phase Equilibria for $CO_2$ in Liquified Natural Gas Components at 77-219K

  • Yun, Sang-Kook
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.61-66
    • /
    • 2003
  • In order to prevent roll-over and a rapid boil-off of LNG in tanks, the phase equilibria of carbon dioxide in liquefied natural gas components as binary mixtures at cryogenic temperatures have been experimentally measured using Fourier transform infrared spectroscopy in conjunction with a specially designed variable pressure/temperature cryostat cell (pathlength 2 mm; pressures up to 30 bar). Solid carbon dioxide has been found to be comparatively soluble in liquid nitrogen (3.25$\times$${10}^{-6}$ mole fraction), liquid methane (1.04$\times$${10}^{-4}$ mole fraction), liquid ethane (3.1$\times$${10}^{-2}$ mole fraction) and liquid propane (6.11$\times$${10}^{-2}$ mole fraction) at their normal boiling temperatures. The solubilities of carbon dioxide in various cryogens, which increased with increasing temperature, are much lower than those obtained by others using gas chromatography. The differences are attributed to infrared spectroscopy selectively measuring dissolved solute in situ whereas gas chromatography measures microscopic particulate solid in addition to dissolved solute.

Investigation of Icing Phenomenon in Liquid Phase LPG Injection System (액상분사식 LPG 연료공급방식의 아이싱현상에 관한 연구)

  • Kim, C.U.;Oh, S.M.;Kang, K.Y.
    • Journal of ILASS-Korea
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2003
  • The liquid phase LPG injection (LPLI) system is considered as one of the next generation fuel supply systems for LPG, vehicles, since it can accomplish the higher power, higher efficiency, and lower emission characteristics than the existing mixer type fuel supply system. However, during the injection of liquid LPG fuel into the inlet duct of an engine, a large quantity of heat is extracted due to evaporation of fuel. A problem is that the moisture in the air freezes around the outlet of a nozzle, which is called icing Phenomenon. It may cause damage to the outlet nozzle of an injector. The frozen ice deposit detached from the nozzle also may cause a considerable damage to the inlet valve or valve seat. In this work, the experimental investigation of the icing phenomenon was carried out. The results showed that the icing phenomenon and process were mainly affected by humidity of inlet air instead of the air temperature in the inlet duct. Also, it was observed that the icing occurs first in the inlet of a nozzle, and grows considerably at the upper part of the nozzle inlet and the opposite side of the nozzle entrance. An LPG fuel, mainly consisting of butane, has lower latent heat of vaporization than that of propane, which is an advantage in controlling the icing phenomenon.

  • PDF

Study on the Regenerating Performance of Liquid Desiccant in the Cooling/Dehumidification System able to use a Solar Water Heater in Summer(On the Analysis of Source Effect by the Design of Experiments) (여름철 냉방/제습시스템 중 태양열 온수기를 적용할 수 있는 액체흡수제의 재생성능에 관한 연구(실험계획법에 의한 요인효과 분석에 관하여))

  • Choi, K.H.;Kim, B.C.;Kim, B.J.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • With the possibility of hot water being able to be used as a heating source in a liquid desiccant system, an experimental apparatus for regeneration of the liquid desiccant was set up and series of experiments were conducted in a climate-controlled chamber. This study was performed to ascertain the influences of experimental factors on regenerating performance and to suggest the optimal combination of factors affecting regeneration rate. Furthermore. in order to figure out the contribution ratio of the factors on regenerating performance, a multi-way factorial design among the design of experiments was adopted. According to experimental results, the most influential factor on regenerating performance was temperature of the liquid desiccant and its contribution ratio was about 79.4%. In addition. the optimal operating combination was as follows; $60^{\circ}C$ of solution temperature, $14\ell$/min of solution flow rate, and 190m3/h of air volume.