• 제목/요약/키워드: Liquid Slug

검색결과 52건 처리시간 0.021초

Flow Visualization of Oscillation Characteristics of Liquid and Vapor Flow in the Oscillating Capillary Tube Heat Pipe

  • Kim, Jong-Soo;Kim, Ju-Won;Jung, Hyun-Seok
    • Journal of Mechanical Science and Technology
    • /
    • 제17권10호
    • /
    • pp.1507-1519
    • /
    • 2003
  • The two-phase flow patterns for both non-loop and loop type oscillating capillary tube heat pipes (OCHPs) were presented in this study. The detailed flow patterns were recorded by a high-speed digital camera for each experimental condition to understand exactly the operation mechanism of the OCHP. The design and operation conditions of the OCHP such as turn number, working fluid, and heat flux were varied. The experimental results showed that the representative flow pattern in the evaporating section of the OCHP was the oscillation of liquid slugs and vapor plugs based on the generation and growth of bubbles by nucleate boiling. As the oscillation of liquid slugs and vapor plugs was very speedy, the flow pattern changed from the capillary slug flow to a pseudo slug flow near the annular flow. The flow of short vapor-liquid slug-train units was the flow pattern in the adiabatic section. In the condensing section, it was the oscillation of liquid slugs and vapor plugs and the circulation of working fluid. The oscillation flow in the loop type OCHP was more active than that in the non-loop type OCHP due to the circulation of working fluid in the OCHP. When the turn number of the OCHP was increased, the oscillation and circulation of working fluid was more active as well as forming the oscillation wave of long liquid slugs and vapor plugs in the OCHP. The oscillation flow of R-142b as the working fluid was more active than that of ethanol and the high efficiency of the heat transfer performance of R -142b was achieved.

고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계 (A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation)

  • 안예찬;차재은;김무환
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별 (Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop)

  • 이상천;이정표;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

A Calculation Model for Fuel Constituent Redistribution and Temperature Distribution on Metallic U-10Zr Fuel Slug of Liquid Metal Reactors

  • Nam, Cheol;Hwang, Woan
    • Nuclear Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.507-517
    • /
    • 1998
  • Unlike conventional fuel types, fuel constituent redistribution and sodium intrusion into the fuel slug are the unique phenomena of the irradiated metallic fuel. A thermal calculation model on metallic U-10 wt.%Zr fuel rod for LMRs is developed with considerations given to these phenomena. The amount of constituent redistribution is estimated based on the thermotransport process. The temperature profile of fuel slug is predicted by taking into account of Zr redistribution, porosity formation and sodium logging effects. A sample calculation is performed and compared to experimental data in literature. As a result, the predicted redistribution and temperature profile are well agreed with experimental data, assuming that 15 times increment of ex-reactor diffusivity, $Q_{r}$ $^{*}$ is -50 kJ/mole and sodium is infiltrated only outside of the fuel slug. Furthermore, the redistribution effects on fuel integrity and fuel temperature profile are discussed.d.

  • PDF

소수성 미니채널 내 움직이는 접촉선을 가진 액체슬러그의 압력 강하에 대한 수치해석 (Numerical study on pressure drop with moving contact lines of dry slug flow in a hydrophobic minichannel)

  • 전준호;박수청;유동인;김태훈;이연원
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.116-121
    • /
    • 2020
  • In this study, a single-phase analysis of droplet slug with different contact angles was performed based on the visualization of experimental results. Droplet slug - flowing between gases in a hydrophobic mini channel - moves with a triple contact line without a gas liquid film on the wall. The results show that the rotational flow inside the droplet occurred; this was compared and verified with the results of two-phase analysis. The pressure field shows pressure rise at the front and rear ends. The effective length - the section that satisfies the laminar flow condition - became shorter as the droplet velocity increased. The Choi's correlation for the effective length agrees with this analysis results with a slight difference. This difference is judged as the difference in the contact angle of the slug model.

광학적 방법을 이용한 슬러그 유동의 기공률 측정 (Measurement of the Void Fraction in Slug Flow using an Optical Method)

  • 김동선
    • 융복합기술연구소 논문집
    • /
    • 제1권2호
    • /
    • pp.25-28
    • /
    • 2011
  • Void fraction has been measured for the gas-liquid cocurrent slug flow in 8mm vertical acrylic tube using an optical method. Bubble speed, length and period could be measured with the two sets of laser-infrared sensor modules mounted 25mm apart alongside the tube, which were designed to detect variation of light intensities with a time delay when two parallel laser beams were refracted successively by a passing bubble. It was found that the results were in good agreement with the previous studies in the literature suggesting that the method used in this study were sound and accurate.

  • PDF

Valve actuation effects on discrete monopropellant slug delivery in a micro-scale fuel injection system

  • McDevitt, M. Ryan;Hitt, Darren L.
    • Advances in aircraft and spacecraft science
    • /
    • 제1권4호
    • /
    • pp.409-425
    • /
    • 2014
  • Converging flows of a gas and a liquid at a microchannel cross junction, under proper conditions, can result in the formation of periodic, dispersed microslugs. This microslug formation phenomenon has been proposed as the basis for a fuel injection system in a novel, 'discrete' monopropellant microthruster designed for use in next-generation miniaturized satellites. Previous experimental studies demonstrated the ability to generate fuel slugs with characteristics commensurate with the intended application during steady-state operation. In this work, numerical and experimental techniques are used to study the effect of valve actuation on slug characteristics, and the results are used to compare with equivalent steady-state slugs. Computational simulations of a valve with a 1 ms valve-actuation cycle show that as the ratio of the response time of the valve to the fully open time is increased, transient effects can increase slug length by up to 17%. The simulations also demonstrate that the effect of the valve is largely independent of surface tension coefficient, which is the thermophysical parameter most responsible for slug formation characteristics. Flow visualization experiments performed using a miniature valve with a 20 ms response time showed less than a 1% change in the length of slugs formed during the actuation cycle. The results of this study indicate that impulse bit and thrust calculations can discount transient effects for slower valves, but as valve technology improves transient effects may become more significant.

Flow Near the Meniscus of a Pressure-Driven Water Slug in Microchannels

  • Kim Sung-Wook;Jin Song-Wan;Yoo Jung-Yul
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.710-716
    • /
    • 2006
  • Micro-PIV system with a high speed CCD camera is used to measure the flow field near the advancing meniscus of a water slug in microchannels. Image shifting technique combined with meniscus detecting technique is proposed to measure the relative velocity of the liquid near the meniscus in a moving reference frame. The proposed method is applied to an advancing front of a slug in microchannels with rectangular cross section. In the case of hydrophilic channel, strong flow from the center to the side wall along the meniscus occurs, while in the case of the hydrophobic channel, the fluid flows in the opposite direction. Further, the velocity near the side wall is higher than the center region velocity, exhibiting the characteristics of a strong shear-driven flow. This phenomenon is explained to be due to the existence of small gaps between the slug and the channel wall at each capillary corner so that the gas flows through the gaps inducing high shear on the slug surface. Simulation of the shape of a static droplet inside a cubic cell obtained by using the Surface Evolver program is supportive of the existence of the gap at the rectangular capillary corners. The flow fields in the circular capillary, in which no such gap exists, are also measured. The results show that a similar flow pattern to that of the hydrophilic rectangular capillary (i.e., center-to-wall flow) is always exhibited regardless of the wettability of the channel wall, which is also indicative of the validity of the above-mentioned assertion.

전자기유량계를 이용한 기포 및 슬러그 유동 측정방법 연구 (Flow Measurement in Bubbly and Slug Flow Regimes Using The Electromagnetic Flowmeter Developed)

  • 차재은;안예찬;서경우;김무환
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1559-1569
    • /
    • 2002
  • In order to investigate the characteristics of electromagnetic flowmeter in two -phase flow, an AC electromagnetic flowmeter was designed and manufactured. In various flow conditions, the signals and noises from the flowmeter were obtained and analyzed by comparison with the observed flow patterns with a high speed CCD camera. The experiment with the void simulators in which rod shaped non-conducting material was used was carried out to investigate the effect of the bubble position and the void fraction on the flowmeter. Based on the results from the void simulator, two -phase flow experiments encompassed from bubbly to slug flow regime were conducted. The simple relation $\Delta$ $U_{TP}$ = $\Delta$ $U_{SP}$ (l-$\alpha$) was verified with measurements of the potential difference and the void fraction. Due to the lack of homogeneity in a rent two -phase flow, the discrepancy between the relation and the present measurement was slightly increased with void fraction and also liquid volumetric flux jf. Whereas there is no difference in the shape of the raw signal between single-phase flow and bubbly flow, the signal amplitude for bubbly flow is higher than that for single -phase flow at the same water flow rate, since the passage area of the water flow is reduced. In the case of slug flow, the phase and the amplitude of the flowmeter output show dramatically the flow characteristics around each slug bubble and the position of a slug bubble itself. Therefore, the electromagnetic flowmeter shows a good possibility of being useful for identifying the flow regimes.ul for identifying the flow regimes.