• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.028 seconds

Comparision of Preparation Methods for Water Soluble Vitamin Analysis in Foods by Reversed-Phase High Performance Liquid Chromatography (역상 고속 액체 크로마토그래피에 의한 식품 중 수용성 비타민 분석을 위한 전처리법의 비교)

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.141-150
    • /
    • 2002
  • Owing to a need for simple extraction and purification for analysis of water soluble vitamins in food samples by RP-HPLC with UV-detector, the methods of bromelain and protease hydrolysis and $C_{18}$ Sep-Pak solid phase extraction were employed. The recoveries of standard water soluble vitamins by the bromelain and protease hydrolysis and $C_{18}$ Sep-Pak solid phase extraction were significantly high compared to AOAC methods in most of vitamins. The contents of pyridoxal determined with protest in the pork was similar, but in the bromelain hydrolysis and AOAC method, was high compared to the results of reference. The niacinamide, thiamin and riboflavin determined with bromelain and protease hydrolysis showed similar values to the results of references. In the potato, pyridoxamine was detected in the AOAC method, which was not detected in the bromelain and protease hydrolysis methods. Pyridoxal contents in the protease hydrolysis and AOAC methods were very similar to the results of references. The recoveries of fortified standard vitamins in food samples were significantly high and accurate compared to those of AOAC methods. The extraction and purification with $C_{18}$ Sep-Pak solid extractor might be considered superior method for the determination of water soluble vitamins in food samples.

Solid Phase Extraction(SPE) of Curcuminoids from Turmeric by Optimization Analytical Condition (최적 분석조건에 의한 강황으로부터 Curcuminoids의 고체상추출(SPE))

  • Lee, Kwang Jin;Ma, Jin Yeul;Kim, Young Jun;Kim, Young Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4927-4935
    • /
    • 2012
  • Turmeric is a medicinal herb with various pharmacological activities. Curcumin, demethoxycurcumin(DMC) and bisdemethoxycurcumin(BDMC) were extracted from turmeric by dipping and ultrasonic wave method. And extraction efficiency was identified using solid phase extraction(SPE). The extracted sample were simultaneously separated and analyzed from three kinds of commercial $C_{18}$ reversed-phase high performance liquid chromatography using water and acetonitrile as mobile phase with isocratic elution mode. Flow rate 1.0mL/min, injection volume $10{\mu}L$ and column oven temperature $40^{\circ}C$ at 425nm wavelength has been conducted. From the experimental results, the optimum mobile phase composition of water/acetonitrile 50/50vol% using RS tech column. It is evident that the amount of curcuminoids extracted(extraction time 4h) by 100% MeOH was higher than any aqueous MeOH composition. Finally, in 100% water extraction, the amount(mAU${\times}$mim) of curcuminoids extracted by SPE was 14.3 and 24.5 times respectively higher than ultrasonic wave and dipping method. The shown results can be applied as sources for pharmaceuticals and functional material.

Determination of VOC in aqueous samples by the combination of headspace (HS) and solid-phase microextraction (SPME) (HS-SPME 방식에 기초한 물 중 VOC 성분의 분석기법에 대한 연구: 3가지 실험 조건의 변화와 분석감도의 관계)

  • Park, Shin-Young;Kim, Ki-Hyun;Yang, H.S.;Ha, Joo-Young;Lee, Ki-Han;Ahn, Ji-Won
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.93-101
    • /
    • 2008
  • The application of solid phase microextraction (SPME) is generally conducted by directly immersing the fiber into the liquid sample or by exposing the fiber in the head space (HS). The extraction temperature, the time of incubation, and application of stirring are often designated to be the most important parameters for achieving the best extraction efficiencies of HS-SPME analysis. In this study, relative importance of these three analytical parameters involved in the HS-SPME method is evaluated using a polydimethylsiloxane/carboxen (PDMS/CAR) fiber. To optimize its operation conditions the competing relationships between different parameters were investigated by comparing the extraction efficiency based on the combination of three parameters and two contracting conditions: (1) heating the sample at 30 vs. 50 C, (2) exposing samples at two durations of 10 vs. 30 min, and (3) application of stirring vs. no stirring. According to our analysis among 8 combination types of HS-SPME method, an extraction condition termed as S50-30 condition ((1) 1200 rpm stirring, (2) $50^{\circ}C$ exposure temp, and (3) 30 min exposure duration) showed maximum recovery rate of 45.5~68.5% relative to an arbitrary reference of direct GC injection. According to this study, the employment of stirring is the most crucial factor to improve extraction efficiency in the application of HS-SPME.

Determination of Heterocyclic Amines in Roasted Fish and Shellfish by Liquid Chromatography-Electrospray Ionization/Mass Spectrometry (Liquid chromatography-mass spectrometry를 이용한 가열 조리된 어패류에서의 heterocyclic amines 함량 분석)

  • Lee, Jae-Hwan;Back, Yoo-Mi;Lee, Kwang-Geun;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.326-333
    • /
    • 2009
  • Heterocyclic aromatic amines (HCAs) are mutagenic and carcinogenic substances that are formed during the heating of protein-rich foods. HCAs are generally found at low amounts in a complex matrix, which requires sophisticated analysis. In this study, HCAs were extracted from lyophilized fish and shellfish samples using solid-phase extraction (SPE) and determined by liquid chromatography-electrospray ionization/mass spectrometry (LC-ESI-MS). The HCA recoveries in the fish and shellfish ranged from 15.7 to 74.7% with standard deviations from 0.2 to 7.63%. And HCA concentrations ranged from 0.8 to 1,117.7 $ng/g^{-1}$ in cooked food samples. 1-methyl-9H-pyrido[3,4-b]indole (Harman), 9H-pyrido[3,4-b]indole (Norharman), and 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) were the most abundant HCAs formed in the muscle of fried mackerel, at levels of 1,117.7, 926.6, and 133.7 ng/g, respectively. 3-amino-1-methyl-5H-pyrido[4,3-b]indole (Trp-P-2), 2-aminodipiryrido[1,2-a:3,2-d]imidazole(Glu-P-2), 2-amino-9H-pyrido[2,3-b]indole(A${\alpha}$C), 2-amino-3methyl-9H-pyrido [1,2-a:3,2-d]imidazole(MeA${\alpha}$C), 2-amino-3,4,7,8-tetramethylimidazo[4,5-f]quinoxaline (TriMeIQx), 2-amino-3,7,8-trimethylimidazo [4,5-f]quinoxaline(7,8-DiMeIQx), and 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) were only detected by small quantities ranged from 1.5 to 98.6 ng/g. Overall, this study provides useful information on HCA levels in fish and shellfish products consumed in Korea.

Development of Simultaneous Analytical Method of Veterinary Antibiotics in Manure using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 퇴비 및 액비 중 항생제 동시 분석법 개발)

  • Chung, Hyung Suk;Lee, Young Jun;Lee, Han Sol;Rahman, Md. Musfiqur;Kabir, Md. Humayun;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.201-210
    • /
    • 2017
  • BACKGROUND: The current study was to monitor of 9 veterinary antibiotics (ceftiofur, clopidol, florfenicol, sulfamethazine, sulfamethoxazole, sulfathiazole, tetracycline, tiamulin, and tylosin) in manure using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive and negative electrospray ionization mode. METHODS AND RESULTS: Sample preparation was carried out using Mcllvaine buffer and citrate salts to adjust the pH of the sample followed by purification with dispersive solid phase extraction (d-SPE). Separation of analytes during LC-MS/MS analysis was conducted using an Eclipse Plus $C_{18}$ column and the mobile phase was in gradient mode with, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations of all tested antibiotics was good, with $R^2$ determination coefficients ${\geq}0.9920$. The limit of detection (LOD) and quantifications (LOQ) were $0.1-67.0{\mu}g/kg$ and $0.4-200.0{\mu}g/kg$, respectively. Analysis of 13 solid and liquid manure samples taken from the Republic of Korea revealed concentrations less than $0.7{\mu}g/kg$ for tiamulin, $1497.6{\mu}g/kg$ for sulfamethazine. CONCLUSION: To monitor 9 veterinary antibiotics from manure samples in 13 provincial areas throughout the Republic of Korea, an analytical method was developed. The developed method was fully validated and successfully applied for monitoring various veterinary antibiotics in manure samples.

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography (고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정)

  • Park, Daejin;Lee, Sunggon;Kim, Woomi
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1456-1462
    • /
    • 2012
  • Sorafenib is a multikinase inhibitor and an oral anticancer drug approved for the treatment of patients with advanced renal cell carcinoma and those with unresectable hepatocellular carcinoma. The purpose of this study was to develop an efficient method of the determination of sorafenib in human plasma using tandem mass spectrometry coupled with liquid chromatography (LC/MS/MS) and validate the method by the guidelines of the Korean Food and Drug Administration (KFDA). Plasma samples ($100{\mu}l$) were added with chlorantraniliprole as an internal standard and then mixed with the 0.1% formic acid-containing extraction solution composed of isopropyl alcohol and ethyl acetate (1:4, v/v). After centrifugation, the supernatant was concentrated at $45^{\circ}C$ under negative pressure and centrifugal force. The residue was reconstituted with a mobile phase and injected into the HPLC instrument using a reverse phase Waters XTerra$^{TM}$ C18 column (particle size $3.5{\mu}m$). Liquid chromatography was carried out within the run time of 5 min using a mobile phase composed of buffer (0.1% formic acid and 10 mM ammonium formate), methanol, and acetonitrile (1:6:3, v/v/v). The analytes were monitored by tandem mass spectrometry in the multiple reaction monitoring method programmed to detect sorafenib at 'm/z 465.2 ${\rightarrow}$ 252.5' and chlorantraniliprole at 'm/z 484.4 ${\rightarrow}$ 286.2' with positive electrospray ionization mode ($ES^+$). The result showed the proper linearity ($r^2$ > 0.99) over the range of 2,000-5,000 ng/ml with good accuracy (90.7-103.9%) and precision (less than 10%). The newly developed method using LC/MS/MS was validated by the guideline of KFDA and identified as more sensitive compared to the previous methods.

Determination of Unimark 1494DB in Petroleum using HPLC (HPLC를 이용한 석유제품 중의 식별제 Unimark 1494DB 분석)

  • Lim, Young-Kwan;Kim, DongKil;Yim, Eui Soon;Shin, Seong-Cheol
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.593-598
    • /
    • 2009
  • In this study, the qualitative and quantitative analytical method for petroleum marker(Unimark 1494DB) in common diesel involved kerosene and byproduct fuel was developed using SPE pretreatment and high performance liquid chromatography. In SPE pretreatment process, the highest concentrated marker was obtained 15 minutes after addition of petroleum sample. The petroleum marker was detected with $1626.92mV{\cdot}sec$ intensity at 9.8 minutes retention time in 1 mg/L content in petrodiesel after pretreatment. Also petroleum marker was selectively identified in an acidic petroleum product which was previously difficult to be analyzed by UV-Vis Spectroscopy.

Antimicrobial Substance against Escherichia coli O157:H7 Produced by Lactobacillus amylovorus ME1

  • Jung, Byung-Moon;Woo, Suk-Gyu;Chung, Kun-Sub
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.679-682
    • /
    • 2008
  • A lactic acid bacterium producing an antimicrobial substance against Escherichia coli O157:H7 was isolated from raw milk and identified as Lactobacillus amylovorus ME-1. In addition to E. coli O157 :H7, the antimicrobial substance also inhibited the growth of Bacillus cereus, Listeria monocytogenes, Pseudomonas aeruginosa, Salmonella typhimurium, Staphylococcus aureus, Streptococcus agalactiae, Streptococcus pyrogenes, and Yersinia enterocolitica. The antimicrobial substance was stable at pH 2-12 and $121^{\circ}C$ for 15 min and insensitive to proteinase K, protease, amylase, and catalase. Purification of the antimicrobial substance was conducted through methanol and acetonitrile/ethylacetate extraction, ultrafiltration with a 500 Da cutoff, thin layer chromatography (TLC) with silicagel 60, and high performance liquid chromatography (HPLC) with a $C_{18}$ reverse phase column. The ${\lambda}_{max}$ of the purified antimicrobial substance was determined as 192 nm by ultra violet (UV) scanning, while the molecular weight was estimated as 453 Da based on the mass spectrum. Accordingly, the current results suggest that the antimicrobial substance from the L. amylovorus ME-1 was not a bacteriocin, but rather a new non-proteinaceous substance distinct from acidophilin, acidolin, diacetyl, and reuterin.

Rendering of Particle-Based Water Data Using Point Rendering Method (점 렌더링 기법을 사용한 입자 기반 물 데이터의 렌더링)

  • Lee, Jae-Hak;Cha, Deuk-Hyun;Chang, Byung-Joon;Ihm, In-Sung;Kim, Jang-Hee;Koo, Bon-Ki
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.1262-1270
    • /
    • 2006
  • 사실적인 물 애니메이션을 위한 격자 기반 시뮬레이션 기법은 자연스러운 물의 움직임뿐만 아니라 부드러운 물의 표면을 잘 표현해주는 장점이 있다. 이러한 격자 기반 방법과 함께 상대적으로 적은 계산으로 안정적인 결과를 산출해주는 입자 기반의 액체 시뮬레이션 기법이 최근 애니메이션 분야에 적용되기 시작했고, 그로 인하여 입자로 이루어진 시뮬레이션 데이터에 특화된 효과적인 렌더링 기술의 개발이 요구되고 있다. 본 논문에서는 주로 3차원 스캔 데이터와 같이 물체 표면을 샘플링 하여 얻어진 점 집합에 대한 렌더링 기법을 확장하여, 위상 변화가 크고 점 집합에 의해 내부까지 표현되는 물 데이터의 특성에 적합한 렌더링 기법을 제안한다. 본 기법에서는 시뮬레이션을 통하여 얻은 입자 데이터로부터 물의 표면을 표현해주는 새로운 점 집합을 생성하고, 시뮬레이션 된 데이터의 특성을 잘 반영하도록 각 점에 대한 법선 벡터와 반지름을 결정한다. 특히 가공된 점 집합 데이터에 대하여 확장된 점 집합 렌더링 기법을 적용함으로써 입자 데이터가 표현해주는 세밀한 부분들을 보존하면서, 부드러운 물의 표면을 가시화할 수 있도록 하였다.

  • PDF