• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.026 seconds

Analysis of Polycyclic Aromatic Hydrocarbon Content in Coffee Beans with Different Preparation Method (전처리 방법에 따른 커피원두 중 polycyclic aromatic hydrocarbons 함량 분석)

  • Nam, He-Jung;Seo, Il-Won;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.157-161
    • /
    • 2009
  • This paper proposes an analytical method for determining amounts of polycyclic aromatic hydrocarbons (PAHs; benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i] perylene) in coffees beans. Soxhlet extraction and liquid/liquid extraction were tested for the quantification of seven PAHs. Soxhlet extraction was followed by cyclohexane extraction and used a silica cartridge. Liquid/liquid extraction was followed by n-hexane extraction and utilized a florisil cartridge. The extracts were analyzed by HPLC-fluorescence detection (FLD) with a Supelcosil LC-PAH column. The PAH recoveries ranged from 78.68 to 96.28% for the liquid/liquid extraction, and from 67.47 to 84.60% for the Soxhlet extraction.

A Study on the Extraction of Monasil PCA using Liquid CO2 (액체 이산화탄소 이용한 Monasil PCA 추출에 대한 연구)

  • Cho, Dong Woo;Oh, Kyoung Shil;Bae, Won;Kim, Hwayong;Lee, Kab-Soo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.684-689
    • /
    • 2012
  • Poly(acrylic acid) (PAA) microspheres is one of the widely-used polymeric materials for the bio-field application and the electric materials. For the synthesis of PAA microspheres, the polymerization technique using surfactants is applied. After the synthesis, the purification and separation processes are required for the removal of surfactant. When general organic solvents were used, many problems, such as huge amount of waste solvent, additional separation processes, and the possibility of residual media, were occurred. Thus, High-pressure Soxhlet extraction using liquid $CO_2$ was developed to solve these problems. In this study, High-pressure Soxhlet extraction of the synthesized PAA microspheres using liquid $CO_2$ was conducted for the removal of Monasil PCA which is used for the dispersion polymerization of acrylic acid in compressed liquid Dimethyl ether (DME). The morphology of the extracted PAA particles was checked by field emission scanning electron microscopy (FE-SEM) and the residual concentration of Monasil PCA was analyzed by inductively coupled plasma - Optical Emission Spectrometer (ICP-OES). For studying the effect of the solvent effect, Soxhlet extraction was conducted using n-hexane, liquid DME, and liquid $CO_2$. In case of n-hexane, some extracted PAA microspheres were produced. However, deformation was also occurred due to the high thermal energy of n-hexane vapor. Liquid DME could not remove Monasil PCA. When using liquid $CO_2$, the extracted PAA microspheres which were free for the residual solvent were produced without deformation. For finding the optimum operating condition, high-pressure Soxhlet extraction was conducted for 8 hours with changing the temperature of reboiler and condenser. When the extractor temperature is $19.6{\pm}0.2^{\circ}C$ and the pressure is $51.5{\pm}0.5$ bar, the best removal efficiency was obtained.

Experimental Study on the Enhancement of Condensation Heat Transfer on a Single Horizontal Tube Utilizing EHD (전장을 이용한 수평관 주위에서의 응축 열전달촉진에 관한 실험적 연구)

  • 유갑종;추홍록;김석준;이성진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3008-3020
    • /
    • 1994
  • Condensation heat transfer on a single horizontal tube with electric fields (Electro-Hydro-Dynamics, (EHD)) has been studied experimentally. Results are presented for EHD enhanced condensation of R-113 on a single horizontal tube using several electrode geometries. Especially, its attention was focused on the effects of electrode geometry, electric field strength and the gap of the electrode. In this study, single wire, helical, ring and mesh electrode were used. The range of the imposed voltage was 0~20 kV. As the voltage was increased the surface of liquid became an unstable wave, stream jet, liquid column and then liquid extraction in sequence. Among the various kinds of electrodes, the single wire electrode is suitable for practical application.

Detectio of Malonaldehyde-thiobarbituric Acid (MA-TBA) Complex by High Performance Liquid Chromatography(HPLC) in a Model System

  • Whang, Key
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.3
    • /
    • pp.167-170
    • /
    • 1999
  • Various concentrations of malonaldehyde (MA) produced upon hydrolysis of 1, 1, 3,3-tetraethoxypropane (TEP) were reacted with 2-thiobarbituric acid (TBA)and th e contents of MA-TBA complex were measured both with spectrophotometer and high performance liquid chromatography (HPLC). As the concentrations of MA-TBA increased, their absorbances and the corresponding HPLC peak areas increased. The correlation coefficient between absorbances and HPLC peak areas of MA-TBA peaks from the other compounds and butanol extraction of the complex increased its recovery its recovery by 29.4% . Measurement of the content of MA-TBA complex for monitoring the development of lipid oxidation was proven to be successful with the use of high performance liquid chromatography.

  • PDF

Solvent-localized in-situ NMR Monitoring by Intermolecular Single-quantum Coherence Study

  • Cha, Jin Wook;Park, Sunghyouk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.4
    • /
    • pp.96-103
    • /
    • 2020
  • A new NMR method to monitor solvent-localized NMR signals in the two-phase liquid system is suggested. This method based on intermolecular single-quantum coherence (iSQC). Here, we exploited the feature of the local action of distant dipolar field (DDF) effect in order to filter out specific NMR signals dissolved in different solvents. This solvent specific iSQC spectroscopy was carried out on a model two-phase liquid system (D-glucose in water/palmitic acid in chloroform), and showed solvent-localized NMR signals. We believe our approaches might be useful in metabolic analysis such as two-phase liquid extraction scheme for labile chemical species.

Comparison of Extraction Procedures for the Determination of Capsaicinoids in Peppers

  • Jeon, Geonuk;Lee, Jun-Soo
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1515-1518
    • /
    • 2009
  • The objective of this study was to compare 3 extraction methods including, solid phase extraction (SPE), acetonitrile extraction, and methanol extraction, for their usefulness as extraction methods to determine capsaicinoids. The determination of capsaicinoids in the extracts was carried out on a reverse-phased high performance liquid chromatography (HPLC) using a fluorescence detector. Three extraction methods, i.e., SPE, acetonitrile extraction, and methanol extraction were compared for the quantification of capsaicinoids using raw peppers and pepper powder. The highest analytical values were observed using methanol extraction and the lowest values using SPE. Also, the analytical method validation parameters such as accuracy, precision, limit of detection, limit of quantitation, and specificity were calculated to ensure the method's validity. This method provides a fast and accurate approach for the determination of capsaicinoids in peppers.

Emulsion liquid membranes for cadmium removal: Studies of extraction efficiency

  • Ahmad, A.L.;Kusumastuti, Adhi;Derek, C.J.C.;Ooi, B.S.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.11-25
    • /
    • 2013
  • Emulsion liquid membrane (ELM) process suffers from emulsion instability problem. So far, emulsion produced by mechanical methods such as stirrer and homogenizer has big size and high emulsion breakage. This paper discussed the application of emulsion produced by sonicator to extract cadmium in a batch ELM system. The emulsions consist of N,N-Dioctyl-1-octanamine (trioctylamine/TOA), nitrogen trihydride (ammonia/NH4OH), sorbitan monooleate (Span 80), and kerosene as carrier, stripping solution, emulsifying agent, and organic diluent, respectively. Effects of comprehensive parameters on extraction efficiency of Cd(II) such as emulsification time, extraction time, stirring speed, surfactant concentration, initial feed phase concentration, carrier concentration, volume ratio of the emulsion to feed phase, and pH of initial feed phase were evaluated. The results showed that extraction efficiencies of Cd(II) greater than 98% could be obtained under the following conditions: 15 minutes of emulsification time, 4 wt.% of Span 80 concentration, 4 wt.% of TOA concentration, 15 minutes of extraction time, 250 rpm of stirring speed, 100 ppm of initial feed concentration, volume ratio of emulsion to feed phase of 1:5, and initial feed pH of 1.53.

Review on the Analytical Methods and Ambient Concentrations of Organic Nitrogenous Compounds in the Atmosphere (대기 유기질소화합물의 분석방법 및 농도)

  • Choi, Na Rae;Kim, Yong Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.120-143
    • /
    • 2018
  • The analytical methods and their ambient levels of organic nitrogenous compounds such as nitrosamines, nitramines (nitroamines), imines, amides and nitro-polycyclic aromatic hydrocarbons (nitro-PAHs) in the atmosphere are summarized and discussed. Sampling for the analysis of organic nitrogenous compounds was mostly conducted using high volume air sampler. The direct liquid extraction (DLE) using sonification and the pressurized liquid extraction (PLE) using the accelerated solvent extraction (ASE) have been frequently employed for the extraction of organic nitrogenous compounds in the atmospheric samples. After extraction, clean-up via filtration and the solid phase extraction (SPE) and concentrations using nitrogen and rotary evaporator have been generally conducted but in some studies the clean-up and concentration steps have been omitted to prevent the loss of analyte and improve the recovery rate of the analytical procedure. Instrumental analysis was mainly carried out using gas chromatography (GC) or the high performance liquid chromatography (HPLC) coupled with the single quadrupole mass spectrometer or tandem mass spectrometer in the electron ionization (EI), positive chemical ionization (PCI) and negative chemical ionization (NCI) mode and analysis sensitivity of nitrosamines and nitramines were higher in NCI mode. Desirable sampling and analysis methods for analyzing particulate organic nitrogenous compounds are suggested.

A Study on the Analytical Method of Trace Metal Ions in Sea Water by Inductively Coupled Plasma - Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 해수중 미량금속의 분석에 관한 연구)

  • Lee, Won;Park, Kyung-Su;Kim, Eun Kyung;Hur, Young-Hoe
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.499-504
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in sea water has been investigated by Inductively Coupled Plasma-Mass Spectrometry. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Recoveries of 99.8% for Cu, 99.6% for Sn, and 97.9% for Bi were obtained for the standard spiked sample. The developed method was applied to analysis of trace metals in sea water.

  • PDF

High Performance Liquid Chromatography (HPLC) Detection of Malonaldehydethiobarbituric Acid (MA-TBA) Complex in Ground Pork

  • Whang, Key
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.3
    • /
    • pp.171-174
    • /
    • 1999
  • For monitoring lipid oxidation development in cooked ground pork during refrigerationm, malonaldehydethiobarbituric acid(MA-TBA) contents were measured using high performance liquid chromatography(HPLC). As the oxidation proceeded during refergeration, TBA-reaction substances(TBARS) absorbances increased and the corresponding HPLC peak areas also increased proportationately. The correlation coefficient between the HPLC peak areas and MA-TBA absorbance were 0.9979. The treatemtn of cetrimide, an ion pairing agent, gave a complete resolution of the MA-TBA complex and the butanol extraction of the complex increased its recovery by 37.8%. Both cetrimide treatment and butanol extraction are essential steps for analyzing MA-TBA complex in ground pork wiht HPLC. A reliable and specific measurement of NA-TBA in ground pork was successfully performed using HPLC.

  • PDF