Effects of the Maghemite for Explosive accident Prevention to Liquefied Petroleum Gas (LPG 폭발사고 예방을 위한 Maghemite의 영향)

  • 박영구
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.67-78
    • /
    • 1996
  • Gas sensing element, $\gamma-Fe_2O_3$was synthesized by dehydration, reduction, and oxidation of $$${\gamma}$-FeOOH, which was synthesized with $FeSO_4\;{\cdot}\;7H_2O$ and NaOH. They were produced as a bulk-type, a thick film-type. Then, their responses and mechanisms of response to the gas of liquefied-petroleum were studied. The qualities of gas sensing elements are decided by the structure and the relative surface area. In the process of $\alpha-FeOOH $synthesis, the effects of reaction conditions as the equivalent ratio, on the structure and the relative surface area of gas sensing element were observed. The changes of the structure were measured with XRD, SEM, TG-DTA and BET. The resistance changes of the synthesized gas sensor in the air were measured. The response ratio were also measured for the changes of working temperature and gas concentration. As a result of analysis with XRD, it was confirmed that the the best conditions for the synthesis of $\alpha -FeOOH$ were equivalent ratio 0.65. The thick film-type element of $\gamma-Fe_2O_3$responded more quickly than the bulk-type did. The structure and the relative surface area of the $\alpha-FeOOH $were confirmed as the important factors deciding gas response charcteristics.

  • PDF

Performance of Blowoff Flow for a LPG Fuel Pump with Various Fuel Filters (LPG 펌프에서 필터 종류에 따른 펌프 토출성능에 대한 연구)

  • Lee, Seok-Hwan;Park, Cheol-Woong;Kim, Chang-Up
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • In recent years, the needs for more fuel-efficient and lower-emission vehicles have driven to use the alternative fuel of LPG(Liquefied Petroleum Gas) which is able to meet the more stringent legislations without many modifications to current engine. LPLi (Liquid Phase LPG Injection) system (the 3rd generation LPG injection system) is the core technology to produce power equivalent to a gasoline engine with less emissions. The LPG fuel pump can supply the compressed LP gas in the liquid phase to engine. The fuel filter is attached in the fuel pump to eliminate the remnants in the liquid phased LP gas and the performance of blowoff flow for a pump can be varied with various filters. In this study, experiments were conducted to investigate the performance and efficiency of the impeller type LPG fuel pump under various filter types of microfiber, double mesh and external filter. And blowoff flow for a LPG fuel pump was measured according to the temperature of the fuel.

  • PDF

A Study on Performance Characteristics According to the Fuel Conditions for a Fuel Pump in LPG Engine (자동차용 LPG 펌프의 연료조건에 따른 성능특성에 관한 연구)

  • Park, Cheol-Woong;Kim, Chang-Up;Choi, Kyo-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.266-274
    • /
    • 2008
  • The need for more fuel-efficient and lower-emission vehicles has driven the technical development of alternative fuels such as Liquefied Petroleum Gas(LPG) which is able to meet the limits of better emission levels without many modifications to current engine design. LPG has a high vapor pressure and lower viscosity and surface tension than diesel and gasoline fuels. These different fuel characteristics make it difficult to apply it for the conventional gasoline or diesel fuel pump directly. In this study, experiments are performed to get performance and efficiency of the fuel pump at different condition as temperature, rotating speeds, composition of fuel. The characteristics of fuel pump is affected by cavitation due to the variation of temperature and composition.

Various Injection Conditions and Fuel Control of an LPG Liquid Injection Engine (다양한 분사조건과 LPG 액상분사엔진의 연료량 제어)

  • Sim Hansub
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • Fuel injection rate of an injector is affected by various injection conditions such as injection duration, fuel temperature, injection pressure, and voltage in LPG liquid injection systems for either a port-fuel-injection(PFI) or a direct injection(DI) in a cylinder. Even fuel injection conditions are changed, the air-fuel ratio should be accurately controlled to educe exhaust emissions. In this study, correction factor for the fuel injection rate of an injector is derived from the density ratio and the pressure difference ratio. A voltage correction factor is researched from injection test results on an LPG liquid injection engine. A compensation method of the fuel injection rate is proposed for a fuel injection control system. The experimental results for the LPG liquid injection system in a SI-engine show that this system works well on experimental range of engine speed and load conditions. And the fuel injection rate is accurately controlled by the proposed compensation method.

액화석유가스(LPG) 지하저장기지에서의 TSP(Tunnel Seismic Prediction)탐사

  • Cha, Seong-Su
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.2
    • /
    • pp.75-86
    • /
    • 2002
  • A TSP(Tunnel Seismic Prediction) survey which is modified VSP(Vertical Seismic Profiling) survey applied in tunnel was carried out at Pyongtaek and Incheon liquefied petroleum gas(LPG) storage cavern during excavation. The TSP survey in Pyongtaek LPG storage cavern which is located below Namyangho was performed to confirm the location and orientation of the fault detected at pre-investigation stage. The TSP survey was carried out in access tunnel, construction tunnel, and watercurtain tunnel to characterize 3 dimensional figure of the fault. The results of TSP survey are compared four in vestigation boreholes drilled in shelter of access tunnel. The fault was also detected by borehole survey and the location was coincided with the result of TSP survey. Depending on the result of TSP survey and core logging, the design such as cavern layout and length was changed. Another TSP survey was performed in Incheon LPG storage cavern which is located below sea. Because of poor geological information at pre-investigation stage and suffering from heavy leakage of groundwater, the TSP survey to detect fracture zone was carried out. The support and grouting design was reflected by the result of TSP survey.

  • PDF

A Study on Reliability Analysis and Quantitative Risk Analysis for Liquefied Petroleum Gas Station (LPG 충전시설에 대한 신뢰도 분석과 정량적 위험성 분석에 관한 연구)

  • Kim In-Won;Jin Sang-Hwa;Kim Tea-Woo;Kim In-Tae;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.40-48
    • /
    • 2001
  • For a Liquified Petroleum Gas(LPG) station, the reliability analysis, such as Fussell-Vesely importance, risk decrease factor and risk increase factor, was carried out and the risk ranks of events were determined. In order to confirm the degree of the risks identified in the reliability analysis, the quantitative risk analysis was done for the equipments which had the large values of risk ranks. As a result of the importance analysis for the LPG station, the external event was identified as the most riskful event. The defect of construction structure and the pipe corrosion were riskful as well. The result of quantitative risk analysis showed that the length of 46.3 meters were estimated to damage the process equipments by the thermal flux from the catastrophic rupture of storage tank in Boiling Liquid Expanding Vapor Explosion.

  • PDF

A Study on the decision of Scattering distance by Shape of Fragments in LPG Tank lorry Explosion (LPG 탱크로리 폭발시 파편 형상에 따른 비산거리 산정에 관한 연구)

  • Lee, Young Jin;Hwang, Yong Woo;Lee, Ik Mo;Moon, Jin Young
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2017
  • LPG is a substance that requires a lot of attention because it can cause fatal damage to people and environment when an accident occurs. LPG is frequently accidents in transportation facilities as well as fixed facilities, among which LPG tank lorries are the most frequent accidents. When the LPG tank is evacuated, the LP gas leaks into two phases, leaks mostly to the gas and leaks to some liquid. At this time, the leaked gas will also sink downward because it is heavier than air, and if it continues to leak, it may form an explosion and explode by the ignition source. The purpose of this study is to present the evacuation distance by analyzing the effect distance of the LPG liquefied petroleum gas in the event of explosion. As a result of calculation of the scattering radius of the fragment, the cylinder fragment was scattered up to 561 m. Therefore, it is appropriate to set the distance to be escaped when the LPG tanker leaks to 561m or more.

A Study on the Quantitative Analysis and Estimation for Surround Building caused by Vapor Cloud Explosion(VCE) in LPG Filling Station (LPG충전소에서 증기운폭발이 주변건물에 미치는 영향의 정량적 해석 및 평가에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.44-49
    • /
    • 2010
  • This paper is estimation of structure damage caused by Explosion in LPG(Liquefied Petroleum Gas) filling station. As we estimate the influence of damage which occur at gas storage tank in filling station. We can utilize the elementary data of safety distance. In this study, the influence of over-pressure caused by VCE(Vapor Cloud Explosion) in filling station was calculated by using the Hopkinson's scaling law and the accident damage was estimated by applying the influence on the adjacent structure into the probit model. As a result of the damage estimation conducted by using the probit model, both the damage possibility of explosion overpressure to structures of max 265 meters away and to glass bursting of 1150 meters away was nearly zero in open space explosion.

A Study for the Performance Improvement by Fumigation LPG on Diesel Engine using a Used Frying Oil (폐식용유를 사용한 디젤기관에서의 LPG 공급에 의한 성능개선에 관한 연구)

  • 조기현;황의현;백태실;정형길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.16-24
    • /
    • 2000
  • In this study, using frying oil, performance of engine and emission concentration were compared with the case of using diesel oil. And results are as follows. 1. Engine torque and brake horse power indicate nearly same value as the case of using diesel fuel. 2. Temperature of exhaust gas was increased with as high engine speed and load. 3. To reduce concentration of hydrocarbon, it is effective to operate using used frying oil in low engine speed and load, and adding LPG in high engine speed and load. 4. Concerning with concentration of carbon mono oxide and smoke emission, it was assured, that as engine load increased, lower concentration emitted in case of utilizing mixed fuel than that of utilizing pure diesel fuel.

  • PDF

A study on Innovation of Installation Technology for LPG Storage Tank through Pugh Method (퓨 방법을 통한 LPG저장탱크 혁신시공기술)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1045-1048
    • /
    • 2010
  • 본 연구는 LPG 충전소 등에서 운용하는 저장탱크에 대하여 퓨방법을 통하여, 기존의 지상형과 지하형의 장점과 단점을 비교 판정하여 혁신시공법으로 고객만족을 실현시키기 위함이다. 자동차 연료로서 LPG(Liquefied Petroleum Gas)의 사용은 대기오염을 줄이는데 효과적으로 사용이 빠르게 확산되고 있다. 하지만 가스사용이 늘어나면서 폭발과 화재에 의한 인명피해가 해마다 발생하고 있으며, 특히 대규모 저장시설에서의 가스사고는 사회적으로 심각한 문제를 야기하고 있다. 따라서, 본 연구는 LPG를 대량으로 취급 저장하는 시설에서 운용하는 저장탱크의 설치방법을 개선하기 위하여 아이디어 판단기법중 하나인 퓨(Pugh) 방법으로 판단하면 기존의 지상형과 지하매몰형, 지하격납형에서 안전성과 토지이용률이 우수한 지하격납저장탱크가 가장 효과적임을 알 수 있다.

  • PDF