• Title/Summary/Keyword: Linked Operation

Search Result 323, Processing Time 0.024 seconds

Glucose Diffusion Limiting Membrane Based on Polyethyleneimine (PEI) Hydrogel for the Stabilization of Glucose Sensor

  • Kim, Suk-Joon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.225-229
    • /
    • 2021
  • Commercially available continuous glucose sensors require the operation stability for more than two weeks. Typically, the sensor comprises a sensing layer and an over-coating layer for the stable operation inside the body. In the sensing layer, enzymes and mediators are cross-linked together for the effective sensing of the glucose. The over-coating layer limits the flux of glucose and works as a biocompatible layer to the body fluids. Here, we report the simple preparation of the flux-limiting layer by the condensation of polyethyleneimine (PEI), tri-epoxide linker, and trimethylolpropane triglycidyl ether (PTGE). The sensor is constructed by a layer-by-layer drop-coating of the sensing layer containing glucose dehydrogenase and the PEI-derived blocking layer. It is stable for more than 14 days, which is enough for the sensor in the continuous monitor glucose monitoring (CGM) system.

An Institutional Review of Farming Transfer to Revitalize Management Transfer (경영이양활성화를 위한 농업경영이양의 제도적 고찰)

  • Lee, S.Y.;Kim, J.J.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.22 no.2
    • /
    • pp.23-36
    • /
    • 2020
  • The purpose of this study is to understand the phenomenon of agricultural management transfer and to present a plan to activate Korean management transfer through institutional consideration. To this end, the domestic and overseas agricultural management transfer system was identified, and an appropriate institutional plan for the country was sought. There are six ways to activate the management transfer system proposed in this study. First, establishment of an agricultural management transfer agency, second, training and utilization of management transfer experts, third, establishment of an agricultural succession certification support institution, fourth, operation of specialized training courses for management transfer, fifth, (local government) linked operation of a farming support center, sixth, agricultural management transfer legislation and securing of budgets. The above agricultural management transfer system is expected to contribute to the advancement of management transfer activation.

Proposal of Electronic Engineering Exploration Learning Operation Using Computing Thinking Ability

  • LEE, Seung-Woo;LEE, Sangwon
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.110-117
    • /
    • 2021
  • The purpose of the study is to develop effective teaching methods to strengthen the major learning capabilities of electronic engineering learners through inquiry learning using computing thinking ability. To this end, first, in the electronic engineering curriculum, we performed teaching-learning through an inquiry and learning model related to mathematics, probability, and statistics under the theme of various majors in electronic engineering, focusing on understanding computing thinking skills. Second, an efficient electronic engineering subject inquiry class operation using computing thinking ability was conducted, and electronic engineering-linked education contents based on the components of computer thinking were presented. Third, by conducting a case study on inquiry-style teaching using computing thinking skills in the electronic engineering curriculum, we identified the validity of the teaching method to strengthen major competency. In order to prepare for the 4th Industrial Revolution, by implementing mathematics, probability, statistics-related linkage, and convergence education to foster convergent talent, we tried to present effective electronic engineering major competency enhancement measures and cope with innovative technological changes.

A Practical Research for More Efficient Utilization of Water Resources in the South-Western Part of Korea (서남부지역 수자원의 효율적 이용방안)

  • 김현영;서영제;최용선;문종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.279-286
    • /
    • 1998
  • The south-western part of Korea is situated in an unbalance of water supply and demand relating to the Keum, Mankyung, Dongjin and Youngsan River and their estuary reservoirs. For example, the Keum River estuary reservoir is discharging the larger amount of yearly runoff into the sea due to the small storage capacity, while Saemankeum estuary reservoir which is under construction, has the smaller runoff amount comparing with its storage capacity, And the downstream area of the Youngsan River, such as Youngkwang, Youngam are deficient in water due in larger demand and smaller supply. In order to solve the above unbalanced water supply and demand and also to improve the water use efficiency, the Hierarchical Operation Model for Multi-reservoir System(HOMMS) has been developed and applied to analyze the multi-reservoir operation assuming that the above reservoirs were linked each other. The result of this study shows that 2,148MCM of annual additional water requirement for agricultural and rural water demands are required in this region at 2011 of target year, and these demands can be resolved by diverting and reusing 1,913MCM of the released water from the estuary reservoirs into the sea.

  • PDF

Complex ESP Systems Proposal based on Pump Syringe and Electronically injector Modules for Medical Application

  • HAMROUNI, Chafaa
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.175-188
    • /
    • 2020
  • The paper focuses on conception and development of complex systems composed mainly by a pump syringe subsystem and an electronically injector that facilitates patients saving data operation for medical staff use. We successfully developed conventional approaches for medical system staff requirements, such as system boundary conditions. Decisions at a given level are studied. We propose a complex system architecture, based mainly on patients collected data and ordered stepper injection parameters. System is successfully simulated and prototyped. Design and implement tests are accomplished, the proposed system ensures both the electric syringe pump and the electric injector operation. In addition, this new system introduces several additional options as patient database development and automation injection operation. Development and software operating tests to create a visualization control interface are validated. The solution performs syringe function and electronic injector. User can manage a syringe in two C modes of technology. We propose a program composed of two linked parts. If an error such radiologist bad target selection is made, an image with lower intrinsic quality emerges. Developed Shoot syringe different electronic cards are simulated and prototyped, in addition, maps are driven, prototype. All tests results are accomplished.

Optimal air-conditioning system operating control strategies in summer (여름철 공조시스템의 최적 운전 제어 방식)

  • Huh, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

Anesthetic Management of the Oral Surgery in a Child with Hemophilia A - A case report - (혈우병 환아에서의 구강외과 수술 마취관리 -증례 보고-)

  • Park, Chang-Joo;Lee, Jong-Ho;Yum, Kwang-Won;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.2 no.1 s.2
    • /
    • pp.27-32
    • /
    • 2002
  • Hemophilia A is the most common congenital bleeding disorder, which is sex-linked disease, caused by a deficiency of clotting factor VIII. We experienced a case of alveolorrhaphy using iliac bone graft under general anesthesia for the correction of bilateral cleft alveolus in 10-year-old boy with hemophilia A. Factor VIII activity in this patient was 0.7%, on the severely deficient level, and aPTT was 100 seconds. Just before operation, he received 1,750 units of factor VIII intravenously for loading dose. After we confirmed his factor VIII activity improved to 95% and aPTT to 38.4 seconds, operation was begun. No more transfusion was needed during the operation. In his postoperative care, he received 50 units/kg a 12 hours for 3 days and 30 units/kg a 12 days for 2 days. His factor VIII activity was maintained at 57-139% during his hospitalization. He was discharged without any anesthetic complication. So we report this successful case of anesthetic management for the oral surgery in a child with hemophilia A.

  • PDF

A Computing Switching Angle for Adaptive Operation of SRM for Drill (드릴용 SRM의 최적운전을 위한 스위칭각 산정)

  • Choe, Gyeong-Ho;Kim, Nam-Hun;Baek, Won-Sik;Kim, Dong-Hui;No, Chae-Gyun;Kim, Min-Hoe;Hwang, Don-Ha
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.11
    • /
    • pp.575-582
    • /
    • 2001
  • This paper presents a calculating method of switching angle for adaptive switched reluctance motor (SRM) drive of a drill. The operation of the SRM is completely characterized by the flux linked by one phase winding which depends only on the current in that same phase winding and the rotor position. An efficiently adaptive SRM drive is possible on appropriately scheduling the commutation angles with accurate rotor position, supplied current value and speed information. An adaptive SRM drive with reduction torque ripple should be controlled by an optimized phase current control along with rotor position. Therefore, we are suggested a computing method of switching turn-on and off angles for adaptationally SRM operation with varied rotor speed and load. To probe the computing method, we have some simulation and experiment, it is shown a good result that can be computing the optimized switching angles for an electric drill motor.

  • PDF

Efficient Utilization of Water Resources Linking The Estuary Reservoirs in Asan-Dae Ho Area of Korea (아산호(牙山湖)에서 대호호(大湖湖) 연안(沿岸)의 담수호(淡水湖) 연결(連結)에 의한 효율적(效率的)인 수자원(水資源) 이용방안(利用方案))

  • Choi, Han-Kyu;Koo, Bon-Soo;Lee, Seong-Hong
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.425-430
    • /
    • 1998
  • The Asan Bay area Korea is situated in an unbalance or water supply and demand relating to the Ansung, Sapkyo, Dangjin and Youmwha rivers and their estuary reservoirs. The multi-reservoir operation was studied by the Hierarchical Operation Model for Multi-reservoir System(HOMMS) assuming that these four estuary reservoirs were linked to each other in order. The result of this study shows that storage capacity deficiency in 2011 was estimated as 8 MCM in the Sapkyo and 31 MCMin Dae Ho estuary reservoir, respectively. In case of linking four reservoirs, the water deficiency will not occurs in all the reservoirs even if additional agricultural water of 78 MCM/yr was supplied. Total additional water demand for agricultural, municipal and industrial uses was estimated as 321.9 MCM/yr while additional supply by linking the reservoirs was estimated as 160.4 MCM/yr. 50% of additional demand. The remaining 161.5MCM/yr would be supplied transferring other watershed.

  • PDF

Performance Optimization of High Specific Speed Pump-Turbines by Means of Numerical Flow Simulation (CFD) and Model Testing

  • Kerschberger, Peter;Gehrer, Arno
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.352-359
    • /
    • 2010
  • In recent years, the market has shown increasing interest in pump-turbines. The prompt availability of pumped storage plants and the benefits to the power system achieved by peak lopping, providing reserve capacity, and rapid response in frequency control are providing a growing advantage. In this context, there is a need to develop pumpturbines that can reliably withstand dynamic operation modes, fast changes of discharge rate by adjusting the variable diffuser vanes, as well as fast changes from pumping to turbine operation. In the first part of the present study, various flow patterns linked to operation of a pump-turbine system are discussed. In this context, pump and turbine modes are presented separately and different load cases are shown in each operating mode. In order to create modern, competitive pump-turbine designs, this study further explains what design challenges should be considered in defining the geometry of a pump-turbine impeller. The second part of the paper describes an innovative, staggered approach to impeller development, applied to a low head pump-turbine project. The first level of the process consists of optimization strategies based on evolutionary algorithms together with 3D in-viscid flow analysis. In the next stage, the hydraulic behavior of both pump mode and turbine mode is evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Finally, the progress in hydraulic design is demonstrated by model test results that show a significant improvement in hydraulic performance compared to an existing reference design.