• 제목/요약/키워드: Link switching

검색결과 462건 처리시간 0.027초

전류 리플을 이용한 직류단 캐패시터의 용량 선정 기법에 관한 연구 (A Study on Capacitance Selection Method of DC-link Capacitor Using Current Ripple)

  • 김용휴;이병훈;황선환
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.47-53
    • /
    • 2022
  • This paper proposes a method for selecting the capacitance of DC-link capacitors of inverters. In general, the DC-link capacitance of the inverter system must be considered for DC-link voltage, ripple current, switching frequency, ripple voltage, and pulse-width modulation techniques. Therefore, the appropriate capacitance can be determined by finding the rms and peak values of the ripple current of the capacitor. In this paper, the process of extracting the ripple current of DC-link capacitor is described in detail. In addition, the simple method for finding DC-link capacitor capacitance using the result value is presented through the simulations.

항공 데이터버스용 링크 우회방식을 가진 고장감내 이더넷 시스템의 성능 분석 (Performance of Fault-tolerant Ethernet System with Link-bypass scheme for Airbone Databus)

  • 송대연;윤종호;정한균;김승환
    • 대한전자공학회논문지TC
    • /
    • 제44권9호
    • /
    • pp.46-53
    • /
    • 2007
  • 일반적인 이더넷 브리지망에서의 링크장애복구는 Spanning Tree Protocol(STP) 또는 Rapid STP에 의존하여 왔다. 그러나, 이러한 STP는 기본적인 복구지연시간 때문에 항공기제어와 같은 실시간 서비스에 필요한 신속한 장애 복구기능을 제공하지 못한다. 본 논문에서는 BcN의 백본 장비간의 내고장성을 제공하는 ITU-T의 Automatic Protection Switching(APS)기술과 최근 A380에 항공기용 데이터버스로 기본 장착되고 있는 ARINC 664의 Avionic Full Duplex Switched Ethernet(AFDX)의 성능을 비교한 후, AFDX기술의 성능 향상을 위하여 기존 AFDX망을 메쉬 형태로 모든 스위치들을 연결하고, 링크 장애 발생 시 장애가 발생한 링크를 우회하여 데이터를 전송하여 고장 감내 기능을 향상시킬 수 있는 링크 우회 기법을 제안하였다. 제안된 방법의 성능을 비교 검증하기 위하여 NS-2를 사용하여 기존의 이더넷과 AFDX, APS 및 제안된 기법을 모의실험하였다. 이러한 AFDX기술은 항공기뿐만 아니라 일반적인 BcN 백본망이나 산업자동화 통신망에서도 적용될 수 있는 특징이 있을 것이다.

4-PAM signaling을 이용한 high speed serial link transmitter (High Speed Serial Link Transmitter Using 4-PAM Signaling)

  • 정지경;이정준;범진욱;정영한
    • 대한전자공학회논문지SD
    • /
    • 제46권11호
    • /
    • pp.84-91
    • /
    • 2009
  • 본 논문은 multi-level signaling을 이용한 high speed serial link transmitter에 관하여 제안하였다. High speed serial link에서 수 Gb/s를 달성하기 위해 4-pulse amplitude modulation (PAM) 을 사용하였다. 4-PAM은 4개의 level로 한 symbol time에 2 bit data를 전송함으로써 binary signaling보다 2배 빠른 data 전송이 가능해졌다. 제안된 4-PAM transmitter는 전압 output 대신 전류 output을 생성하며 이로 인해 driver의 switching time이 빨라져서 더 높은 속도의 transmitter를 구현할 수 있었다. $2^5-1$ pseudo-random bit sequence (PRBS) 생성기는 built-in self test (BIST)를 하기 위해 on-chip으로 설계되었다. 본 연구는 동부 하이텍 $0.18{\mu}m$ CMOS 공정을 통하여 설계되었으며 1.8 V supply voltage에서 eye 크기가 160 mV 이고 최대 동작 속도는 8 Gb/s이다. 칩 전체 면적은 $0.7\times0.6mm^2$이며 전력 소모는 98 mW이다.

Delta-Modulation 기법을 적용한 병렬 공진형 소프트 스위칭 인버터 (Parallel Resonant Soft Switching Inverter based on Delta-Modulation Method)

  • 최광수;김영호;김준구;원충연;정용채;오동성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.212-214
    • /
    • 2009
  • In this paper, we have proposed a Parallel Resonant Soft Switching Inverter based on Delta-Modulation Method. The conventional full-bridge inverter generates switching losses due to the hard switching. The proposed inverter operates soft switching using a DC-link switch and resonant circuit. So, all of the switches in the proposed inverter operates soft switching. Therefore the proposed inverter can reduce not only switching loss but also capacity and size of passive devices due to the resonant elements. The validity of the proposed inverter is verified thorough the theoretical analysis and simulation.

  • PDF

Single-Phase Improved Auxiliary Resonant Snubber Inverter that Reduces the Auxiliary Current and THD

  • Zhang, Hailin;Kou, Baoquan;Zhang, He;Zhang, Lu
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.1991-2004
    • /
    • 2016
  • An LC filter is required to reduce the output current ripple in the auxiliary resonant snubber inverter (ARSI) for high-performance applications. However, if the traditional control method is used in the ARSI with LC filter, then unnecessary current flows in the auxiliary circuit. In addressing this problem, a novel load-adaptive control that fully uses the filter inductor current ripple to realize the soft-switching of the main switches is proposed. Compared with the traditional control implemented in the ARSI with LC filter, the proposed control can reduce the required auxiliary current, contributing to higher efficiency and DC-link voltage utilization. In this study, the detailed circuit operation in the light load mode (LLM) and the heavy load mode (HLM) considering the inductor current ripple is described. The characteristics of the improved ARSI are expressed mathematically. A prototype with 200 kHz switching frequency, 80 V DC voltage, and 8 A maximum output current was developed to verify the effectiveness of the improved ARSI. The proposed ARSI was found to successfully operate in the LLM and HLM, achieving zero-voltage switching (ZVS) of the main switches and zero-current switching (ZCS) of the auxiliary switches from zero load to full load. The DC-link voltage utilization of the proposed control is 0.758, which is 0.022 higher than that of the traditional control. The peak efficiency is 91.75% at 8 A output current for the proposed control, higher than 89.73% for the traditional control. Meanwhile, the carrier harmonics is reduced from -44 dB to -66 dB through the addition of the LC filter.

B4 인버터의 제어성능 향상을 위한 전압보상 기법 (A Voltage Compensation Method to Improve the Control Performance for B4 Inverters)

  • 오재윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.317-320
    • /
    • 2000
  • This paper proposes a voltage compensation method to improve the control performance of B4 inverter which is studied for low-cost drive systems. The B4 inverter employs only four switches and it has a center-tapped connection in the split dc-link capacitors to one phase of a three-phase motor. In the B4 topology unbalan-cd three-phase voltages will be generated by the dc link voltage ripple. To solve this problem we present a voltage compensation method which adjusts switching times considering dc link voltage ripple. The proposed method is verified by simulation results,

  • PDF

공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템 (Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side)

  • 유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

Analysis of Forward Link Capacity for a DS/CDMA System with Multirate Traffic Sources

  • Park, Wan;Kim, Jin-Young
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.125-128
    • /
    • 2000
  • In this paper, we derive forward link Erlang capacity reflecting both outage probability and blocking probability of each traffic type in mixed traffics environment. We firstly determine the number of available virtual trunks of the forward link from a circuit switching perspective. Then, capacity sharing model and generalized Erlang model are employed to derive joint Erlang capacity of various traffics types.

  • PDF

Providing survivability for virtual networks against substrate network failure

  • Wang, Ying;Chen, Qingyun;Li, Wenjing;Qiu, Xuesong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4023-4043
    • /
    • 2016
  • Network virtualization has been regarded as a core attribute of the Future Internet. In a network virtualization environment (NVE), multiple heterogeneous virtual networks can coexist on a shared substrate network. Thus, a substrate network failure may affect multiple virtual networks. In this case, it is increasingly critical to provide survivability for the virtual networks against the substrate network failures. Previous research focused on mechanisms that ensure the resilience of the virtual network. However, the resource efficiency is still important to make the mapping scheme practical. In this paper, we study the survivable virtual network embedding mechanisms against substrate link and node failure from the perspective of improving the resource efficiency. For substrate link survivability, we propose a load-balancing and re-configuration strategy to improve the acceptance ratio and bandwidth utilization ratio. For substrate node survivability, we develop a minimum cost heuristic based on a divided network model and a backup resource cost model, which can both satisfy the location constraints of virtual node and increase the sharing degree of the backup resources. Simulations are conducted to evaluate the performance of the solutions. The proposed load balancing and re-configuration strategy for substrate link survivability outperforms other approaches in terms of acceptance ratio and bandwidth utilization ratio. And the proposed minimum cost heuristic for substrate node survivability gets a good performance in term of acceptance ratio.

스위칭 중계기를 사용한 이동통신 시스템의 채널용량 (Channel Capacity of Mobile Communication System using Switching Repeater)

  • 김장욱;최완;오창헌;조성준
    • 한국전자파학회논문지
    • /
    • 제13권1호
    • /
    • pp.33-39
    • /
    • 2002
  • 이동통신 시스템에서 지하 주차장, 지하상가, 터널, 빌딩 내부 등과 같이 기지국에 의한 신호의 커버리지가 충분하지 못한 지역들이 발생하게 된다. 이러한 영역의 경제적인 해결 방안으로 중계기가 널리 사용된다. 그러나, 중계기의 수가 증가할수록 역방향 링크의 기지국으로 유입되는 잡음 전력이 중계기의 숫자에 비례하여 증가하기 때문에 채널 용량이 감소하게 된다. 수십, 수백개의 중계기가 하나의 기지국에 연결되는 상황에서 이러한 채널 용량의 감소는 더 이상 무시할 수 없다. 본 논문에서는 커버리지 내에 통화 중인 사용자가 없을 때에 자동적으로 동작하지 않는 스위칭 중계기론 제안하였다. 스위칭 중계기를 사용하면 중계기의 커버리지 내에 통화중인 사용자가 없을 때 불필요한 잡음 레벨을 줄일 수 있다. 스위칭 중계기를 사용한 이동통신 시스템의 역방향 링크 채널 용량을 수학적으로 분석하여 스위칭 중계기를 사용하지 않는 상황과 비교하였다. 그 결과 스위칭 중계기를 사용할 때 충분히 채널용량이 개선되었음을 알 수 있었다.