• Title/Summary/Keyword: Link Types

Search Result 430, Processing Time 0.022 seconds

Enhancing the Seismic Performance of Multi-storey Buildings with a Modular Tied Braced Frame System with Added Energy Dissipating Devices

  • Tremblay, R.;Chen, L.;Tirca, L.
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • The tied braced frame (TBF) system was developed to achieve uniform seismic inelastic demand along the height of multi-storey eccentrically braced steel frames. A modular tied braced frame (M-TBF) configuration has been recently proposed to reach the same objective while reducing the large axial force demand imposed on the vertical tie members connecting the link beams together in TBFs. M-TBFs may however experience variations in storey drifts at levels where the ties have been removed to form the modules. In this paper, the possibility of reducing the discontinuity in displacement response of a 16-storey M-TBF structure by introducing energy dissipating (ED) devices between the modules is examined. Two M-TBF configurations are investigated: an M-TBF with two 8-storey modules and an M-TBF with four 4-storey modules. Three types of ED devices are studied: friction dampers (FD), buckling restrained bracing (BRB) members and self-centering energy dissipative (SCED) members. The ED devices were sized such that no additional force demand was imposed on the discontinuous tie members. Nonlinear response history analysis showed that all three ED systems can be used to reduce discontinuities in storey drifts of M-TBFs. The BRB members experienced the smallest peak deformations whereas minimum residual deformations were obtained with the SCED devices.

Extraction of Disaster link Matrix Considering Flood Damage of Low-rise Structures due to Typhoon Effects (태풍 영향으로 인한 저층 시설물의 침수피해를 고려한 재난 연계 매트릭스 도출)

  • Lee, Byung-Hoon;Lee, Byung-Jin;Oh, Seung-Hee;Jung, Woo-Sug;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.209-214
    • /
    • 2018
  • In this paper, we recognize the damage caused by a disaster to a facility in the event of a large-scale disaster and present the possible disasters in the form of a matrix. The typhoon was selected as a major disaster and covered mainly the flood damage, a possible damage caused by the typhoon. Flood damage is mainly caused by flooding, and damage is determined by flooding and flow rate, and the results of applying this to low-rise facilities are derived. In addition, the results were derived by applying a method of classification of disaster types in a matrix format to make it easy to see at a glance the connection between disasters caused by damage to a facility. Continuing research in the form presented in this paper will help us identify additional disasters as an occurrence of a disaster.

Association of High LDH and Low Glucose Levels in Pleural Space with HER2 Expression in Non-Small Cell Lung Cancer

  • Ziaian, Bijan;Saberi, Ali;Ghayyoumi, Mohammad Ali;Safaei, Akbar;Ghaderi, Abbas;Mojtahedi, Zahra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1617-1620
    • /
    • 2014
  • Background: Evidence shows direct link of HER2 to increased glycolysis and over production of lactate dehydrogenase (LDH). HER2 overexpression, high LDH and low glucose pleural levels are associated with poor prognosis in lung cancer. Here, their relationships were investigated. Materials and Methods: HER2 positivity was studied using immunohistochemistry in non-small cell lung cancer. Glucose and LDH levels were measured using commercial colorimetric kits. Results: Of 42 patients (29 adenocarcinoma and 13 squamous cell carcinoma), 28 (66.7%) were HER2-negative, 14 (33.3%) were HER2- positive, including 9 (21.4%) weakly stained (1+) and 5 (11.9%) moderately stained (2+) samples. The relationship between HER2 and glucose and LDH levels were tested in 20 newly diagnosed lung cancer patients who had simultaneous pleural and serum samples. Pleural and serum LDH levels were increased, and pleural glucose levels were decreased with the scale of HER2 positivity, and that the difference in glucose levels between HER2-negative group and HER2-positive patients scored at 2+ reached statistical significance (p=0.02). This latter group all had pleural glucose levels below 40 mg/dl. Conclusions: For the first time, we showed a significant association between low pleural glucose level and overexpression of HER2 in lung cancer. Further investigations are warranted to disclose the association of HER2 with low pleural glucose levels in other populations, with a larger sample size, in malignant pleural effusions caused by other types of cancer, and finally to assess employment as a screening tool for finding HER2-positive cases of lung cancer.

A Study on Efficient Fault-Diagnosis for Multistage Interconnection Networks (다단 상호 연결 네트워크를 위한 효율적인 고장 진단에 관한 연구)

  • Bae, Sung-Hwan;Kim, Dae-Ik;Lee, Sang-Tae;Chon, Byoung-SIl
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.73-81
    • /
    • 1996
  • In multiprocessor systems with multiple processors and memories, efficient communication between processors and memories is critical for high performance. Various types of multistage networks have been proposed. The economic feasibility and the improvements in both computing throughput and fault tolerance/diagnosis have been some of the most important factors in the development of these computer systems. In this paper, we present an efficient algorithm for the diagnosis of generalized cube interconnection networks with a fan-in/fan-out of 2. Also, using the assumed fault model present total fault diagnosis by generating suitable fault-detection and fault-location test sets for link stuck fault, switching element fault in direct/cross states, including broadcast diagnosis methods based on some basic properties or generalized cube interconnection networks. Finally, we illustrate some example.

  • PDF

Capacity Expansion Modeling of Water-distribution Network using GIS, VE, and LCC (GIS와 VE, LCC 개념에 의한 동적 상수도관망 대안 결정)

  • Kim, Hyeng-Bok
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 1999.12a
    • /
    • pp.21-25
    • /
    • 1999
  • Planning support systems(PSS) add more advanced spatial analysis functions than Geographic information systems(GIS) and intertemporal functions to the functions of spatial decision support systems(SDSS). This paper reports the continuing development of a PSS providing a framework that facilitates urban planners and civil engineers in conducting coherent deliberations about planning, design and operation & maintenance(O&M) of water-distribution networks for urban growth management. The PSS using dynamic optimization model, modeling-to-generate-alternatives, value engineering(VE) and life-cycle cost(LCC) can generate network alternatives in consideration of initial cost and O&H cost. Users can define alternatives by the direct manipulation of networks or by the manipulation of parameters in the models. The water-distribution network analysis model evaluates the performance of the user-defined alternatives. The PSS can be extended to include the functions of generating sewer network alternatives, combining water-distribution and sewer networks, eventually the function of planning, design and O&H of housing sites. Capacity expansion by the dynamic water-distribution network optimization model using MINLP includes three advantages over capacity expansion using optimal control theory(Kim and Hopkins 1996): 1) finds expansion alternatives including future capacity expansion times, sizes, locations, and pipe types of a water-distribution network provided, 2) has the capabilities to do the capacity expansion of each link spatially and intertemporally, and 3) requires less interaction between models. The modeling using MINLP is limited in addressing the relationship between cost, price, and demand, which the optimal control approach can consider. Strictly speaking, the construction and O&M costs of water-distribution networks influence the price charged for the served water, which in turn influence the. This limitation can be justified in rather small area because price per unit water in the area must be same as that of neighboring area, i.e., the price is determined administratively. Planners and engineers can put emphasis on capacity expansion without consideration of the relationship between cost, price, and demand.

  • PDF

Design of Digital Broadcasting Data Service showing Supplementary Information of each Type of ID Advertisement (ID 광고의 유형별 부가정보를 보여주는 디지털방송 데이터서비스 설계)

  • KO, Kwangil
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1671-1677
    • /
    • 2018
  • The advertisement market is an industry that is heavily influenced by media changes. As the digital broadcasting has settled, TV, a typical advertisement medium, has evolved from a passive content consuming medium into a platform for operating various data services as well as broadcasting programs. These changes mean that viewers are able to actively consume TV contents including advertisement, so the broadcasting industry needs to consider about the growth strategies that link the advertisement market with data services. This study designed a digital broadcasting data service that provides supplementary information of ID advertisement with short exposure time (less than 10 seconds) and insufficient space (less than 1/4 of TV screen). Specifically, we designed the user scenario and user interface of the data service, defined representative types of ID advertisement and the supplementary information for each type, developed a method, based on the international digital broadcasting standard DVB, for providing the supplementary information to the data service.

Presence of Tumour-infiltrating FOXP3+ Lymphocytes Correlates with Immature Tumour Angiogenesis in Renal Cell Carcinomas

  • Zhan, Hai-Lun;Gao, Xin;Zhou, Xiang-Fu;Pu, Xiao-Yong;Wang, De-Juan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.867-872
    • /
    • 2012
  • Background: $FOXP3^+$ regulatory T cells (Tregs) inhibit effector T cell functions and are implicated in tumour progression. However, together with microvessel density (MVD) they remain controversial prognostic predictors for renal cell carcinoma (RCC), and potential associations have yet to be determined. The objective of this study was to determine the prognostic significance of Tregs and MVD and their potential relationship in RCCs. Design: Paraffin-embedded tissues from 62 RCC patients were analysed using immunohistochemistry to detect $FOXP3^+$ lymphocytes, and double immunohistochemistry to detect different microvessel types in the tumour interior, rim and normal kidney tissue, and their correlation with clinicopathological characteristics. Survival analysis was also performed. Results: The presence of $FOXP3^+$ cells in the tumour interior or the rim showed no correlation with death from RCC and other pathological characteristics. Negative correlations were noted between the immature MVD in the tumour interior or the rim and tumour size, tumour stage and overall survival; however, there was no correlation with the nuclear grade or pathological type. A positive correlation between $FOXP3^+$ Tregs and immature MVD (r=0.363, P=0.014) and mature MVD (r=0.383, P=0.009) was confirmed in the tumour interior. However, there was no correlation between $FOXP3^+$ Tregs and mature MVD (r=0.281, P=0.076) or immature MVD (r=0.064, P=0.692) in the tumour rim. Conclusions: In this study, a positive correlation between the presence of $FOXP3^+$ Tregs and immature and mature MVD in RCC was confirmed, which suggests a link between suppression of immunity, tumour angiogenesis and poor prognosis.

The Implementation of a Multi-Band Network Selection System (멀티대역 네트워크 선택기 시스템 구현)

  • Cho, A-ra;Yun, Changho;Lim, Yong-kon;Choi, Youngchol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1999-2007
    • /
    • 2017
  • In this paper, we implement a multi-band network selection (MNS) system based on Linux operating system which determines the optimal communication link for given network conditions among the available LTE, very high frequency (VHF), and high frequency (HF). The implemented software consists of a network interface, an MNS server, and a user GUI. We perform indoor test to verify the function of the implemented MNS system using two sets of MNS system. To this end, two types of VHF communication links that follow ITU-R M.1842-1 Annex 1 and Annex 4 are emulated in software. In addition, the HF transmission (reception) port of one MNS is directly connected to the HF reception (transmission) port of another MNS. We demonstrate through indoor tests that the implemented MNS system can support seamless maritime communication service in spite of artificial disconnection or re-connection of LTE, VHFs, and HF. The implemented MNS system is applicable to various maritime communication services including e-navigation.

Nature-Friendly Design Characteristics of Outdoor Spaces in Brand Apartments (브랜드 아파트에 나타난 자연친화적 외부공간의 디자인 특성에 관한 연구)

  • Hwang, Yeonsook;Lee, SongHyun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.93-100
    • /
    • 2013
  • A outdoor space of the brand apartment can improve the quality of the whole environment in apartment and has differentiated identity in apartment housing through various versions of the green space and water space plan. The purpose of this study is to evaluate nature-friendly design characteristics in brand apartments and to offer a basic information for planning of brand apartment. In concrete, nature-friendly design did by green space and water space that can analyze by visual, and investigation contents divided to position, form, user behavior, link space from user viewpoint by case study. This study examined a case of eight brand apartments located in Gangnamgu, Seoul. We has divided the characteristics of a green space into horizontal type, vertical type, multi-dimensional type and has divided the water space into stagnant water type, flowing stream type, waterfall type and fountain type. The findings are summarized as follows: First, in case of the space of brand apartment, the application of horizontal and vertical greenery was lower compare with multi-dimensional green space. The most of items for multi-dimensional greenery have been planned to the open space and promenade. Second, a stagnant water type of water space features well used in most of the cases but a water space of signs of activity like a flowing stream, waterfall, fountain types were underused because of problem of administrative and maintenance expenses. Thirdly, Water space of brand apartments was planned with specialization item by apartment housing but green space does not have differentiated item and was planned by most similar form.

Low-Latency Programmable Look-Up Table Routing Engine for Parallel Computers (병렬 컴퓨터를 위한 저지연 프로그램형 조견표 경로지정 엔진)

  • Chang, Nae-Hyuck
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.6 no.2
    • /
    • pp.244-253
    • /
    • 2000
  • Since no single routing-switching combination performs the best under various different types of applications, a flexible network is required to support a range of polices. This paper introduces an implementation of a look-up table routing engine offering flexible routing and switching polices without performance degradation unlike those based on microprocessors. By deciding contents of look-up tables, the engine can implement wormhole routing, virtual cut-through routing, and packet switching, as well as hybrid switching, under a variety of routing algorithms. Since the routing engine has a piplelined look-up table architecture, the routing delay is as small as one flit, and thus it can overlap multiple routing actions without performance degradation in comparison with hardwired routers dedicated to a specific policy. Because four pipeline stages do not induce a hazard, expensive forwarding logic is not required. The routing engine can accommodate four physical links with a time shared cut-through bus or single link with a cross-bar switch. It is implemented using Xilinx 4000 series FPGA.

  • PDF