• Title/Summary/Keyword: Linearity improvement

Search Result 173, Processing Time 0.03 seconds

A Study on Effect Analysis and Design Optimization of Tire and ABS Logic for Vehicle Braking Performance Improvement (차량 제동성능 개선을 위한 타이어 인자 분석 및 최적설계에 대한 연구)

  • Ki, Won Yong;Lee, Gwang Woo;Heo, Seung Jin;Kang, Dae Oh;Kim, Ki Woon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.581-587
    • /
    • 2016
  • Braking is a basic and an important safety feature for all vehicles, and the final braking performance of a vehicle is determined by the vehicle's ABS performance and tire performance. However, the combination of excellent ABS and tires will not always ensure good braking performance. This is due to the fact that tire performance has non-linearity and uncertainty in predicting the repeated increase and decrease of wheel slip when activating the ABS, thus increasing the uncertainty of tire performance prediction. Furthermore, existing studies predicted braking performance after using an ABS that used a wheel slip control as a controller, which was different from an actual vehicle's ABS that controlled angular acceleration, therefore causing a decrease in the prediction accuracy of the braking performance. This paper reverse-designed the ABS that controlled angular acceleration based on the information on brake pressure, etc., which were obtained from vehicle tests, and established a braking performance prediction analysis model by combining a multi-body dynamics(MBD) vehicle model and a magic formula(MF) tire model. The established analysis model was verified after comparing it with the results of the braking tests of an actual vehicle. Using this analysis model, this study analyzed the braking effect by vehicle factor, and finally designed a tire that had optimized braking performance. As a result of this study, it was possible to design the MF tire model whose braking performance improved by 9.2 %.

A Study on Estimation of Beat Frequency in a Water Level Measurement Radar (수위 측정 레이다에서의 비트 주파수 추정에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1791-1797
    • /
    • 2014
  • A water level measurement radar estimates beat frequencies to extract the corresponding water level information for water resource management. Therefore, it is required to maintain the high degree of reliability and accuracy in beat frequency estimates. However, Beat spectra of water surface return echoes can have very widely varying shapes according to system frequency linearity, measurement environments and weather conditions. Therefore, serious problems may arise in maintaining the reliability and accuracy of the conventional level estimation method. Therefore, in this paper, high resolution spectrum estimates are analyzed for improvement of the conventional method. These methods show that the more accurate level measurement can be possible on the condition that SNR is higher than a certain required threshold. However, if SNR is too low, the conventional method shows that estimates are more reliable than the suggested method though absolute errors are too large.

Improvement of pregnancy rate after deep uterine artificial insemination with frozen-thawed cauda epididymal spermatozoa in Hanwoo cattle

  • Kang, Sung-Sik;Kim, Ui-Hyung;Ahn, Jun Sang;Won, Jeong Il;Cho, Sang-Rae
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.36 no.2
    • /
    • pp.82-90
    • /
    • 2021
  • In the present study, we examined if deep uterine artificial insemination (DUAI) can improve the pregnancy rate of artificial insemination (AI) using epididymal spermatozoa (ES) in Hanwoo cattle. The estrus cycles of 88 Hanwoo cows were synchronized, and 17 cows were artificially inseminated using the DUAI method with ES, 20 cows were artificially inseminated via the uterine body (BUAI) method with ES, and as a control, 51 cows were inseminated by using the BUAI method with ejaculated spermatozoa from 1 proven bull after frozen thawing. The pregnancy rate of the DUAI method (58.8%) was higher than that of the BUAI method (25.0%, p = 0.0498). The motility of ES was examined immediately after thawing and after 3 and 6 h of incubation. The rapid progressive sperm motility of the control group was significantly higher than that of the ES group immediately after thawing and after 3 and 6 h of incubation (p < 0.05). The straight line velocity and average path velocity of the ES group after 6 h of incubation were significantly lower than those in the control group (p < 0.05). The linearity and amplitude of lateral head of ES were lower than those at 6 h (p < 0.05). The flagellar beat cross frequency and hyperactivation of ES were lower than the control spermatozoa immediately after thawing and at 3 h (p < 0.05). These motility parameters suggested that ES had a low motility and fertilization ability compared to the control spermatozoa. After frozen-thawing and 3 h of incubation, the percentage of live spermatozoa with intact acrosomes in the ES was significantly lower than that in ejaculated spermatozoa (p < 0.05). Our findings suggested that the DUAI method can overcome the low pregnancy rate of ES, despite the low motility, viability, and fertilization ability of ES.

Synergistic effects of CNT and CB inclusion on the piezoresistive sensing behaviors of cementitious composites blended with fly ash

  • Jang, Daeik;Yoon, H.N.;Yang, Beomjoo;Seo, Joonho;Farooq, Shah Z.;Lee, H.K.
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.351-359
    • /
    • 2022
  • The present study investigated the synergistic effects of carbon nanotube (CNT) and carbon black (CB) inclusions on the piezoresistive sensing behaviors of cementitious composites. Four different CNT and CB combinations were considered to form different conductive networks in the binder material composed of Portland cement and fly ash. The cement was substituted with fly ash at levels of 0 or 50% by the mass of binder. The specimens were cured up to 100 days to observe the variations of the electrical characteristics with hydration progress, and the piezoresistive sensing behaviors of the specimens were measured under cyclic loading tests. The fabricated specimens were additionally evaluated with flowability, resistivity and cyclic loading tests, and morphological analysis. The scanning electron microscopy and energy disperse X-ray spectroscopy test results indicated that CNT and CB inclusion induced synergistic formations of electrically conductive networks, which led to an improvement of piezoresistive sensing behaviors. Moreover, the incorporation of fly ash having Fe3+ components decreased the electrical resistivity, improving both the linearity of fractional changes in the electrical resistivity and reproducibility expressed as R2 under cyclic loading conditions.

Enhancement of BIM Modeling Automation Algorithm for Linear-Based Tunnel Infrastructure and Development of BIM Modeling Automation System (선형기반 터널 인프라 구조물의 BIM 모델링 자동화 알고리즘 개선 및 BIM 모델링 자동화 시스템 개발)

  • Kim, Yun-Ok;Kim, Ji-Young; Kim, Tae-Min;Moon, So-Yeong
    • Journal of KIBIM
    • /
    • v.13 no.3
    • /
    • pp.1-11
    • /
    • 2023
  • In order to use BIM as a tool for improving the productivity and quality of products in the construction industry, a BIM model must be created from the design stage first. Infrastructure structures such as bridges and tunnels are mainly created based on three-dimensional alignment in the generation of BIM models. Especially, generation of BIM models based on three-dimensional linearity has high task difficulty and algorithms for automating BIM modeling for railway infra structures have been suggested in previous studies. This study improved the BIM modeling automation algorithm of railway infrastructures and developed a system based on the algorithm so that it can be easily used by ordinary users. The system was built as an add-in system of Autodesk's Revit. As an improvement first, it is possible to arrange different libraries for each pattern, enabling various uses. In addition, it can be created models of several members with a single process and the system can automatically places structures that are added periodically, such as Rock Bolt and Fore Polling. Finally, 3D length information and volume for each pattern are automatically calculated for more accurate 3D-based volume calculation. This study contributes to increasing user accessibility by building a BIM modeling automation algorithm into a system. The system is expected to improve the efficiency of BIM modeling creation of linear-based infra structures, including railway infrastructure.

Soluble Fiber Effect on Human Serum Leptin and Adiponectin: A Systematic Review and Dose-Response Meta-Analysis

  • Ali Zeinabi;Hadi Ghaedi;Seyed Ali Hosseini
    • Clinical Nutrition Research
    • /
    • v.12 no.4
    • /
    • pp.320-335
    • /
    • 2023
  • Literature showed that soluble fiber has beneficial effects on cardiometabolic risk factors and leptin and adiponectin serum levels. Our aim in this meta-analysis was to determine the effect of soluble fiber supplementation on leptin and adiponectin serum levels. A systematic search was conducted using PubMed, Scopus, and ISI Web of Science for eligible trials up to December 2021. A random-effects model was used to pool calculated effect sizes. Our analysis showed that soluble fiber supplementation did not significantly affect adiponectin (standardized mean difference [SMD], -0.49 Hedges's, 95% confidence interval [CI], -1.20, 0.21, p value = 0.167; I2 = 95.4, p value < 0.001) and leptin (SMD, -0.8 Hedges's, 95% CI, -1.70, 0.08, p value = 0.076; I2 = 94.6, p value < 0.001) concentrations in comparison with placebo. However, in the subgroup, soluble fiber supplementation had a significant improvement in leptin concentration in overweight and obese patients (SMD, -0.22 Hedges's, 95% CI, -0.43, -0.01, p value = 0.048) and a non-significant beneficial effect in adiponectin level in female (SMD, 0.29 Hedges's, 95% CI, -0.13, 0.71, p value = 0.183) and diabetic patients (SMD, 0.32 Hedges's, 95% CI, -0.67, 1.32, p value = 0.526). A non-linear association between soluble fiber dosage and adiponectin (pnon-linearity < 0.001) was observed. Soluble fiber supplementation could not change the circulatory leptin and adiponectin levels. However, beneficial effects were seen in overweight and obese leptin, and increases in adiponectin may also be observed in female and diabetic patients. Further studies are needed to confirm this results.

Motional kinematics of Frozen-thawed Korean native cattle semen use of computer aided semen analysis(CASA) system (컴퓨터 정액자동분석에 의한 동결융해 한우 정액의 운동특성 연구)

  • Lee, Kang-nam;Lee, Byeong-chun;Kim, Jung-tae;Park, Jong-im;Shin, Tae-young;Hwang, Woo-suk
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.898-908
    • /
    • 1998
  • The aim of this experiments were to assess the time-interval change of motional characteristics in frozen-thawed semen of Korean native cattle (KNC) by using computer aided semen analysis (CASA) technology. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system (SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber (Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The measurement parameters in SIAS were as follows ; frame rate = 30 frames per sec, image capture = 1 sec, minimum motile speed = $10{\mu}m/s$, maximum countable sperm number = 400. Statistical analysis was done by Student t-test with use of the Sigma plot program on a IBM personal computer. The dancemean(DNM) and hyperactivated sperm(HYP) of frozen-thawed KNC semen kinematics were significantly decreased(p < 0.05) after 10 min of incubation at $37^{\circ}C$ water bath. But, wobble(WOB) of same sample semen was significantly increased(p < 0.05) after 10 min of incubation and significantly decrease(p < 0.05) after 60 min of same incubation. And, after 30 mim of incubation, significantly differences were found most of motion kinematics, motifity(MOT), curvilinear velocity(VCL), straight line velocity(VSL), average path velocity(VAP), amplitude of lateral head displacement(ALH), beat cross frequency(BCF), mean angular displacement(MAD), dance(DNC), on same sample semen. The DNM of KNC semen sample was variable kinematics after 30 min of incubation. Also, the linearity(LIN) and straightness(STR) was significantly decreased(p < 0.05) from 60 min of incubation. In conclusion, the AI within 30 min after thawing of frozen semen can be an effective method for obtaining high fertility rate in KNC reproductive program.

  • PDF

A Design of Wideband Frequency Synthesizer for Mobile-DTV Applications (Mobile-DTV 응용을 위한 광대역 주파수 합성기의 설계)

  • Moon, Je-Cheol;Moon, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.40-49
    • /
    • 2008
  • A Frequency synthesizer for mobile-DTV applications is implemented using $0.18{\mu}m$ CMOS process with 1.8V supply. PMOS transistors are chosen for VCO core to reduce phase noise. The measurement result of VCO frequency range is 800MHz-1.67GHz using switchable inductors, capacitors and varactors. We use varactor bias technique for the improvement of VCO gain linearity, and the number of varactor biasing are minimized as two. VCO gain deterioration is also improved by using the varactor switching technique. The VCO gain and interval of VCO gain are maintained as low and improved using the VCO frequency calibration block. The sigma-delta modulator for fractional divider is designed by the co-simualtion method for accuracy and efficiency improvement. The VCO, PFD, CP and LF are verified by Cadence Spectre, and the sigma-delta modulator is simulated using Matlab Simulink, ModelSim and HSPICE. The power consumption of the frequency synthesizer is 18mW, and the VCO has 52.1% tuning range according to the VCO maximum output frequency. The VCO phase noise is lower than -100dBc/Hz at 1MHz at 1MHz offset for 1GHz, 1.5GHz, and 2GHz output frequencies.

Improvement in the Dispersion Stability of Iron Oxide (Magnetite, Fe3O4) Particles with Polymer Dispersant Inject (고분자 분산제 주입을 통한 철산화물(Magnetite, Fe3O4) 입자의 분산 안정성 향상)

  • Song, Geun Dong;Kim, Mun Hwan;Lee, Yong Taek;Maeng, Wan Young
    • Applied Chemistry for Engineering
    • /
    • v.24 no.6
    • /
    • pp.656-662
    • /
    • 2013
  • The iron oxide ($Fe_3O_4$) particles in the coolant of the secondary system of a nuclear power plant reduce the heat transfer performance or induce corrosion on the surface of the heat transfer tube. To prevent these problems, we conducted a study to improve the dispersion stability of iron oxide using polymeric dispersant injection in simulated secondary system water. The three kinds of anionic polymers containing carboxyl groups were selected. The dispersion characteristics of the iron oxide particles with the polymeric dispersants were evaluated by performing a settling test and measuring the transmission, the zeta potential, and the hydrodynamic particle size of the colloid solutions. Polymeric dispersants had a significant impact on the iron oxide dispersion stability in an aqueous solution. While the dispersant injection tended to improve the dispersion stability, the dispersion stability of iron oxide did not increase linearly with an increase in the dispersant concentration. This non-linearity is due to the agglomerations between the iron oxide particles above a critical dispersant concentration. The effect of the dispersant on the dispersion stability improvement was significant when the dispersant concentration ratio (ppm, dispersant/magnetite) was in the range of 0.1 to 0.01. This suggests that the optimization of dispersant concentration is required to maximize the iron oxide removal effect with the dispersant injection considering the applied environments, the iron oxide concentration and the concentration ratio of dispersant to iron oxide.

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.