• Title/Summary/Keyword: Linear transfer

Search Result 1,138, Processing Time 0.034 seconds

BLIND IDENTIFICATION OF IMPACTING SIGNAL USING HIGHER ORDER STATISTICS (고차통계를 이용한 충격/불량신호 탐지)

  • Seo, Jong-Soo;J.K. Hammond
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1044-1049
    • /
    • 2001
  • Classical deconvolution methods for source identification following linear filtering can only be used if the transfer function of the system is known. For many practical situations, however, this information is not accessible and/or is time varying. The problem addressed here is that of reconstruction of the original input from only the measured signal. This is known as 'blind deconvolution'. By using Higher Order Statistics (HOS), the restoration of the input signal is established through the maximisation of higher order moments (cumulants) with respect to the characteristics of the signals concerned. This restoration is achieved by constructing an inverse filter considering the choice of the initial inverse filter type. As a practical application, an experimental verification is carried out for the restoration of our impacting signal arising in the response of a cantilever beam with an end stop when randomly excited.

  • PDF

A Study on Cleaning Process for Benzene Recovery in Activated Carbon Bed (활성탄을 충전한 흡착탑에서 벤젠 회수를 위한 세정공정의 연구)

  • Kang, Sung-Won;Min, Byong-Hoon;Suh, Sung-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.108-116
    • /
    • 2002
  • Experimental Study was carried out for benzene desorption by purge gas or evacuation in an activated carbon bed. As purge gas flow rate increased, desorption rate increased due to the higher interstitial linear gas velocity. For various purge gas flow rates, desoption curves almost got together if they were plotted against dimensionless time. At a higher flow rate, mass transfer zone became narrower. Temperature drop in the bed was more fast and severe at higher flow rates and higher outer temperature. It was found out that desorption was almost completed when the temperature in the drop of the bed returned to the initial temperature before temperature drop. Desorption by vacuum purge was completed in shorter time than desorption by purge gas. Countercurrent purge was more effective than cocurrent purge.

The Design of the IIR Differintegrator and its Application in Edge Detection

  • Jain, Madhu;Gupta, Maneesha;Jain, N.K.
    • Journal of Information Processing Systems
    • /
    • v.10 no.2
    • /
    • pp.223-239
    • /
    • 2014
  • New IIR digital differintegrators (differentiator and integrator) with very minor absolute relative errors are presented in this paper. The digital integrator is designed by interpolating some of the existing integrators. The optimum value of the interpolation ratio is obtained through linear programming optimization. Subsequently, by modifying the transfer function of the proposed integrator appropriately, new digital differentiator is obtained. Simulation results demonstrate that the proposed differintegrator are a more accurate approximation of ideal ones, than the existing differintegrators. Furthermore, the proposed differentiator has been tested in an image processing application. Edges characterize boundaries and are, therefore, a problem of fundamental importance in image processing. For comparison purpose Prewitt, Sobel, Roberts, Canny, Laplacian of Gaussian (LOG), Zerocross operators were used and their results are displayed. The results of edge detection by some of the existing differentiators are also provided. The simulation results have shown the superiority of the proposed approach over existing ones.

Improved Sampling Method For Volume Rendering (Volume Rendering를 위한 향상된 Sampling 방법)

  • 박재영;이병일;최흥국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.213-216
    • /
    • 2000
  • 본 논문에서는 volume rendering 기법을 이용하여 2차원 MRI 영상들을 합성하여 3차원 영상 만들 때 보다 해상도를 높이기 위한 개선된 sampling방법을 소개한다 2차원 슬라이스 영상들이 3차원으로 재구성할 때 voxel 기반으로 렌더링을 하기 때문에 오브젝트의 내부 영역까지도 볼 수 있는 것이 volume rendering의 가장 큰 장점이다. 따라서 영상을 재구성하는 과정에서 보다 향상된 interpolation을 적용시켜서 공간 해상도를 향상시키면 보다 명확하게 오브젝트 내부 정보를 살펴 볼 수 있다. 본 논문에서는 nearest neighbor 이나 linear 같은 interpolation으로 sampling한 방법보다 cubic interpolation을 3차원 공간에서 적용 시켜서 보다 resampling이 잘 되도록 하여 해상도를 향상시켜 보았다. 이렇게 향상된 Interpolation 적용시켜서 렌더링할 때 얼마나 오브젝트 내부 영역이 잘 가시화가 되었는지 transfer function을 적용시켜서 오브젝트 내부 정보를 렌더링 해보았고, 임의의 축으로 오브젝트을 잘라서 2D 단면 영상으로 출력해 보았다. 보다 향상된 interpolation을 적용시켜서 resampling을 하면 영상 해상도가 개선되었음을 볼 수 있었다.

  • PDF

The Charge Transfer Complexes of Monoalkylbenzene with Iodine in Carbon Tetrachloride (I)

  • Oh-Cheun Kwun
    • Bulletin of the Korean Chemical Society
    • /
    • v.1 no.2
    • /
    • pp.62-68
    • /
    • 1980
  • Ultraviolet spectrophotometric investigations have been carried out the systems of monoalkylbenzene with iodine in carbon tetrachloride. The results reveal the formation of one to one molecular complexes. The equilibrium constants for these complexes of representative monosubstituted benzene reveal the following order of increasing stability: benzene < methyl- < ethyl- < n-propyl-benzene. The value of ${\Delta}H$, ${\Delta}G$, and ${\Delta}S$ for interaction of a number of monoalkyl substituted benzene with iodine has been determinated. In general, as ΛH becomes increasingly negative, corresponding decreases in ${\Delta}G$ and ${\Delta}S$ values are observed, and these variation are linear. The thermodynamic constants become increasingly negative with increasing monoalkyl substitution of the aromatic donor nucleus. The complex bond is therefore weak, and its formation is accompanied by relatively small entropy changes.

Research on the Output Characteristic of Thermoelectric Module according to the thickness variation of Polymer Pad (고분자 필름의 두께변화에 따른 열전소자의 출력 특성변화에 관한 연구)

  • Jang, Ho-Sung;Kim, Jae-Jung;Kim, In-Kwan;Kim, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.976-981
    • /
    • 2006
  • In case of attaching thermoelectric module and heat source, the polymer pad is attached on the $Al_2O_3$ plate, which is cooling side of thermoelectric module, in order to enhance mechanical safety of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

A functionally graded magneto-thermoelastic half space with memory-dependent derivatives heat transfer

  • Ezzat, Magdy A.;El-Bary, Alaa A.
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • In this work, the model of magneto-thermoelasticity based on memory-dependent derivative (MDD) is applied to a one-dimensional thermal shock problem for a functionally graded half-space whose surface is assumed to be traction free and subjected to an arbitrary thermal loading. The $Lam{\acute{e}}^{\prime}s$ modulii are taken as functions of the vertical distance from the surface of thermoelastic perfect conducting medium in the presence of a uniform magnetic field. Laplace transform and the perturbation techniques are used to derive the solution in the Laplace transform domain. A numerical method is employed for the inversion of the Laplace transforms. The effects of the time-delay on the temperature, stress and displacement distribution for different linear forms of Kernel functions are discussed. Numerical results are represented graphically and discussed.

Bond-slip effect in steel-concrete composite flexural members: Part 1 - Simplified numerical model

  • Lee, WonHo;Kwak, Hyo-Gyoung;Hwang, Ju-young
    • Steel and Composite Structures
    • /
    • v.32 no.4
    • /
    • pp.537-548
    • /
    • 2019
  • This paper introduces an improved numerical model which can consider the bond-slip effect in steel-concrete composite structures without taking double nodes to minimize the complexity in constructing a finite element model. On the basis of a linear partial interaction theory and the use of the bond link element, the slip behavior is defined and the equivalent modulus of elasticity and yield strength for steel is derived. A solution procedure to evaluate the slip behavior along the interface of the composite flexural members is also proposed. After constructing the transfer matrix relation at an element level, successive application of the constructed relation is conducted from the first element to the last element with the compatibility condition and equilibrium equations at each node. Finally, correlation studies between numerical results and experimental data are conducted with the objective of establishing the validity of the proposed numerical model.

211At and 211At-labeled radiopharmaceuticals for targeted alpha therapy

  • Kang, Choong Mo;Lee, Kyo Chul;Lee, Yong Jin
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.99-105
    • /
    • 2018
  • $^{211}At$ is an alpha emitting radionuclide, which can be produced using cyclotron with alpha beam. In addition, its strong linear energy transfer and iodine-like chemistry make that $^{211}At$ is one of the most attractive radionuclide in the field of targeted alpha therapy. In this review, production, labeling, and radiopharmaceuticals of $^{211}At$ will be discussed.

Numerical simulation of non-isothermal flow in oil reservoirs using a two-equation model

  • dos Santos Heringer, Juan Diego;de Souza Debossam, Joao Gabriel;de Souza, Grazione;Souto, Helio Pedro Amaral
    • Coupled systems mechanics
    • /
    • v.8 no.2
    • /
    • pp.147-168
    • /
    • 2019
  • This work aims to simulate three-dimensional heavy oil flow in a reservoir with heater-wells. Mass, momentum and energy balances, as well as correlations for rock and fluid properties, are used to obtain non-linear partial differential equations for the fluid pressure and temperature, and for the rock temperature. Heat transfer is simulated using a two-equation model that is more appropriate when fluid and rock have very different thermal properties, and we also perform comparisons between one- and two-equation models. The governing equations are discretized using the Finite Volume Method. For the numerical solution, we apply a linearization and an operator splitting. As a consequence, three algebraic subsystems of linearized equations are solved using the Conjugate Gradient Method. The results obtained show the suitability of the numerical method and the technical feasibility of heating the reservoir with static equipment.