• Title/Summary/Keyword: Linear stapler

Search Result 16, Processing Time 0.018 seconds

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF

Treatment of Spontaneous Serial Lung Lobe Torsion Using Self-Cutting Linear Endoscopic Stapler in a Pekingese Dog under Total Intravenous Anesthesia (페키니즈견에서 발생한 연속적 폐염전의 전정맥마취하 자가 절단식 선형 복강경 스테플러를 이용한 치료)

  • Park, JiYoung;Lee, Young Won;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.490-495
    • /
    • 2013
  • A 9-year old, castrated male Pekingese dog weighing 6.9 kg was referred with one week history of dyspnea, depression, yellow vomiting and abdominal distension. Refractory right lung field opacity was diagnosed as spontaneous right cranial lung lobe torsion (LLT) with collapsed middle lobe on the computed tomography. Four days after diagnosis, right fourth intercostal thoracotomy was performed under propofol-remifentanil based total intravenous anesthesia (TIVA). Right cranial and middle lung lobes were twisted together in a clockwise direction. ENDOPATH-ETS-FLEX-45, an articulating endoscopic linear cutting stapler was applied at the hilus and there were no complications after resection. The patient recovered favorably and has been doing well up to one year follow up. Lung lobe torsion is an uncommon condition in small breed dogs, this case report suggests serial lung lobe torsion of cranial lobe followed by middle lobe in small breed dog, and immediately after diagnosis surgical intervention is beneficial to prevent progression of LLT. Furthermore, using self cutting stapling device and TIVA technique will be helpful for lung lobectomy in dogs.

New Technique of Intracorporeal Anastomosis and Transvaginal Specimen Extraction for Laparoscopic Sigmoid Colectomy

  • Wang, Zheng;Zhang, Xing-Mao;Zhou, Hai-Tao;Liang, Jian-Wei;Zhou, Zhi-Xiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6733-6736
    • /
    • 2014
  • Background: Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Recently, natural orifice specimen extraction (NOSE) and intracorporeal anastomosis have been proposed to minimize abdominal wall trauma and improve the quality of laparoscopic colon resections Objective: To evaluate the feasibility and safety of a new approach combining intracorporeal delta-shaped anastomosis and transvaginal specimen extraction for totally laparoscopic sigmoid colectomy. Materials and Methods: Mobilization of bowel and dissection of lymph nodes were performed laparoscopically. After both proximal and distal incisal edges about 10.0 cm distance from sigmoid neoplasm were transected with an Endoscopic Linear Cutter-Straight, a small incision about 1.0 cm was created on the each colon wall of the contralateral side of the mesentery. Then anvils of an Endoscopic Linear Cutter-Straight were inserted into each colon through the small incisions, and incision and anastomosis between the walls of each colon were performed with a linear stapler. A V-shaped anastomosis was made on the wall and the remnant openings was reclosed with the Endoscopic Linear Cutter-Straight. The culdotomy was enlarged with laparoscopic ultrasound dissector. Transvaginal extraction of specimens was accomplished through a wound protector. Results: Surgery was performed for 11 patients with sigmoid cancer. No intraoperative complications or conversions occurred. The mean operating time was 132 min. All the patients were treated laparoscopically without any postoperative complications. Conclusions: The procedures of intracorporeal delta-shaped anastomosis and transvaginal specimen extraction are safe and oncologically acceptable for selected colon cancer cases.

Liver Lobe Torsion with Hemangiosarcoma in a Dog

  • Park, Jiyoung;Lee, Hae-Beom;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.376-380
    • /
    • 2016
  • A 12-year-old spayed, female Siberian Husky dog weighing 40 kg was referred for sudden collapse without a traumatic history. A splenic mass and hemoperitoneum were identified by ultrasonography and abdominocentesis at a local animal hospital. Emergency exploratory laparotomy was performed once the patient was stabilized. A splenic mass and engorged hepatic mass in the torsed left liver lobe were identified. Partial hepatic lobectomy of the left lateral lobe was performed using a laparoscopic linear self-cutting stapler and the spleen was also removed using an ultrasonic scalpel. Histopathologic examination revealed a diagnosis of splenic hemangiosarcoma with metastasis to the liver. Chemotherapy was not performed because the client did not give consent. The patient was checked regularly until death on POD 324. The metastatic nodules had spread to the lungs and other liver lobes and had gradually increased in size. Liver lobe torsion is a rare condition in dogs, especially accompanying neoplasia. This case supports a potential relationship between liver lobe torsion and neoplastic liver mass in dogs.

Novel Clean End-to-End Anastomosis Method, Without Opening the Stomach Lumen, in Totally Laparoscopic or Robotic Pylorus-Preserving Gastrectomy

  • Takashi Mitsui;Kazuyuki Saito;Yuhei Hakozaki;Yoshiyuki Miwa;Takuji Noro;Emiko Takeshita;Taizen Urahashi;Yasuyuki Seto;Takashi Okuyama;Hideyuki Yoshitomi
    • Journal of Gastric Cancer
    • /
    • v.23 no.4
    • /
    • pp.523-534
    • /
    • 2023
  • Purpose: Intra-abdominal infection is a common postoperative complication of laparoscopic pylorus-preserving gastrectomies (PPGs). Many studies have reported that intra-abdominal infectious complications after gastrectomy adversely affect patient survival outcomes. To prevent gastric fluid leakage into the abdominal cavity, we developed a novel anastomosis method in which the stomach lumen is not opened (termed the non-opened clean end-to-end anastomosis method [NoCEAM]) and evaluated its feasibility. Materials and Methods: Subsequent to lymphadenectomy, the oral and anal resection lines were sutured using an intraoperative endoscope. After closing the stomach circumferentially with clips, the specimen was rolled outward like a "donut." We resected the specimen circumferentially using a linear stapler, and anastomosis was completed simultaneously. We examined the feasibility of this procedure ex vivo, using three porcine stomachs, and in vivo, using one pig. Subsequently, we applied the procedure to 13 consecutive patients with middle-third early gastric cancer utilizing laparotomic, laparoscopic, and robotic PPG. Results: NoCEAM was completed in all porcine models and human cases. In the human cases, the mean operation time (±standard deviation) was 279±51 minutes, and mean blood loss volume was 22±45 mL. The mean number of linear staples used was 5.06±0.76. None of the patients had complications, and all were discharged on the eighth postoperative. The serum total protein, serum albumin, and hemoglobin levels did not change significantly after surgery. Conclusions: NoCEAM is feasible and safe for performing totally laparoscopic or robotic PPG. It may reduce postoperative complications, such as intra-abdominal infections.

Circular Stapled Gastrojejunostomy after Radical Subtotal Gastrectomy - Anastomotic Bleeding and Prevention - (근치적 위아전절제술 후 원형문합기를 이용한 위공장문합술 - 문합부 출혈과 예방 -)

  • Ihn, Myung-Hoon;Kang, Gil-Ho;Cho, Gyu-Seok;Kim, Yong-Jin;Kim, Hyung-Soo;Han, Sun-Uk;Bae, Sang-Ho;Kim, Sung-Yong;Baek, Moo-Joon;Lee, Moon-Soo
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.223-230
    • /
    • 2009
  • Purpose: Circular stapled gastrectomy has been the favored procedure with its feasibility and the shortened operative time, but anastomotic leakage, stenosis and bleeding have been reported as problems. The aim of this study was to identify what can be done to supplement the safety of this technique by examining the potential complications of performing circular stapled gastrojejunosomy after radical subtotal gastrectomy. Materials and Methods: As subjects, this study selected 1,391 patients who underwent gastrojejunostomy after radical subtotal gastrectomy because of gastric cancer at our Department of Surgery from Jan. 1998 to Dec. 2007. The patients were divided into Group I (n=479) who underwent hand-sewn gastrojejunostomy, Group II (n=48) who underwent linear stapled gastrojejunostomy and Group III (n=864) who underwent circular stapled gastrojejunostomy. Group III was re-divided into two subgroups on the basis of the point of time that a visual check was intraoperatively performed at the anastomotic site: Group III-A (n=198) before and Group III-B (n=666) after. The characteristics and complications of the patients were then compared. Results: For the comparison of the complications between Group I, Group II and Group III, anastomotic leakage was found in 7 cases (1.5%) in Group I, in 1 case (2.0%) in Group II and in 10 case (1.2%) in Group III, and anastomotic stenosis were found in 4 cases (0.8%) in Group I, 1 case (2.0%) in Group II and 5 case (0.6%) in Group III. Anastomotic bleeding was found in 32 cases (6.7%) in Group I, in 5 cases (10.4%) in Group II and in 67 cases (7.7%) in Group III. For the comparison of complications between Group III-A and Group III-B, anastomotic bleeding was found in 57 cases (28.8%) in Group III-A and 10 cases (1.5%) in Group III-B and the difference was statistically significant (P=0.037). Conclusion: Circular stapled gastrojejunostomy after radical subtotal gastrectomy is recommended because of the safety and feasibility of this technique, but bleeding at the anastomotic site may be the critical issue. In conclusion, direct inspection for bleeding at the anastomotic site during the operation will improve the safety of performing circular stapler anastomosis.

  • PDF