• Title/Summary/Keyword: Linear motion

Search Result 2,037, Processing Time 0.03 seconds

A Study on the Focal Mechanism of the Hongsung Earthquake from the P-Wave Polarity Distributions (초동극성분포를 이용한 홍성지진의 Focal Mechanism 연구)

  • 김준경
    • The Journal of Engineering Geology
    • /
    • v.1 no.1
    • /
    • pp.121-136
    • /
    • 1991
  • The focal mechanism of the Hongsung Earthquake (1978. Oct. 7, M$_L$=5.0, Latitude 36.62N, Longitude 1 26.67E) was evaulated using the polarity distribution of the P-Waveforms. Through the non-linear computer process, the compatibility of polarity distributions of the 9 P-Waveforms observed at teleseismic distances from the Hongsung Earthquake epicenter was investigated to those of the focal mechanism determined from the varying strike, dip and rake angles. The resultant values for the strike and dip angle of the principal fault plane, which apparently matches very well the sunface lineament of the Hongsung region, are determined to be about 247 degree and 78 degree with uncertainties, respectively. However, the rake angle of the focal mechanism has wide range of 40 degree to 160 degree, which is mainly due to the poor coverage of the azimuthal angle of the observed seismic stations. Due to the consistency of principal stress axes, the resultant focal mechanism could support the current stress regime of that region, which may be caused by subduction of the Pacific Plate under the Eurasia Plate along the Japan Trench. It also provides information of seismic source characteristics of the part of the Korean Peninsula for aseismic design criteria such as Site Specific Response Spectrum and Strong Ground Motion Time History for the nuclear power plants and related nuclear waste disposal facility sites.

  • PDF

Prediction of Cobb-angle for Monitoring System in Adolescent Girls with Idiopathic Scoliosis using Multiple Regression Analysis

  • Seo, Eun Ji;Choi, Ahnryul;Oh, Seung Eel;Park, Hyun Joon;Lee, Dong Jun;Mun, Joung H.
    • Journal of Biosystems Engineering
    • /
    • v.38 no.1
    • /
    • pp.64-71
    • /
    • 2013
  • Purpose: The purpose of this study was to select standing posture parameters that have a significant difference according to the severity of spinal deformity, and to develop a novel Cobb angle prediction model for adolescent girls with idiopathic scoliosis. Methods: Five normal adolescents girls with no history of musculoskeletal disorders, 13 mild scoliosis patients (Cobb angle: $10^{\circ}-25^{\circ}$), and 14 severe scoliosis patients (Cobb angle: $25^{\circ}-50^{\circ}$) participated in this study. Six infrared cameras (VICON) were used to acquire data and 35 standing parameters of scoliosis patients were extracted from previous studies. Using the ANOVA and post-hoc test, parameters that had significant differences were extracted. In addition, these standing posture parameters were utilized to develop a Cobb-angle prediction model through multiple regression analysis. Results: Twenty two of the parameters showed differences between at least two of the three groups and these parameters were used to develop the multi-linear regression model. This model showed a good agreement ($R^2$ = 0.92) between the predicted and the measured Cobb angle. Also, a blind study was performed using 5 random datasets that had not been used in the model and the errors were approximately $3.2{\pm}1.8$. Conclusions: In this study, we demonstrated the possibility of clinically predicting the Cobb angle using a non-invasive technique. Also, monitoring changes in patients with a progressive disease, such as scoliosis, will make possible to have determine the appropriate treatment and rehabilitation strategies without the need for radiation exposure.

The FASCO BMA based on Motion Vector Prediction using Spatio-temporal Correlations (시공간적 상관성을 이용한 움직임 벡터 예측 기반의 FASCO 블럭 정합 알고리즘)

  • 정영훈;김재호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11A
    • /
    • pp.1925-1938
    • /
    • 2001
  • In this paper, a new block-matching algorithm for standard video encoder is presented. The slice competition method is proposed as a new scheme, as opposed to a coarse-to-fine approach. The order of calculating the SAD(Sum of Absolute Difference) to fad the best matching block is changed from a raster order to a dispersed one. Based on this scheme, the increasing SAD curve during its calculation is more linear than that of other curves. Then, the candidates of low probability can be removed in the early stage of calculation. And new MV prediction technique with an adaptive search range scheme also assists the proposed block-matching algorithm. As a result, an average of 13% improvement in computational power is recorded by only the proposed MV prediction technique. Synthetically, the computational power is reduced by 3977∼77% than that of the conventional BMAs. The average MAD is always low in various sequences. The results are also very close to the MAD of the full search block-matching algorithm.

  • PDF

An Analysis of Starting Motions in Time 300m Inline Skating (인라인 스케이트 T300m 출발동작 분석)

  • Park, Ki-Beom;Yang, Jeong-Ok;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.123-137
    • /
    • 2003
  • This study is to present more effective starting skills through analysis of kinematic characteristics of starting motions in 300m Time Trials of Inline Skating. To achieve this goal, 6 athletes, 3 in the national team and 3 in business teams were chosen and their starting motions were examined with three-dimensional image analyses. The results of analyses in regard of positions and speed of the bodily center and angles, angular velocity, and linear velocity of articulations of lower limbs by sections of starting motions are as follows: In case of the central position, though it is effective to reduce the air resistance by lowering the upper part of the body maximumly, it is reasonable to accelerate by raising the upper part of the body to some degree for the running posture at the lower speed in the starting section. In the starting section, it is efficient to minimize the period of time in touching the ground. for this, it is necessary to train for taking motions without slippage while touching the ground. While 3 athletes in business teams kicked the ground as running right after the starting, the others in the national team slid on the ground. As the number of steps increased, the movable speed changed quickly. Thus the movable speed of athletes in the national team indicated big differences in two to three steps. If these factors are well supported, the push-away starting method might be better than the running starting method in terms of improvement of records.

Kinematic analysis of Ire hockey slap shot (아이스 하키 슬랩 샷(slap shot)의 운동학적 분석)

  • Moon, Gon-Sung;Park, Chong-Rul
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.13-28
    • /
    • 2003
  • The purpose of this study was to analyze the kinematic characteristics of Ice hockey slap shot. The subjects of this study were four professional ice hockey players. The reflective markers were attached on the anatomical boundary line of body and the subjects were asked to perform the shot. Ariel Performance Analysis System was used to capture and digitize the shooting image, the data were analyzed by LabView 6i. The results were as fellows. 1. The period of the back swing phase was $0.542{\pm}0.062sec$, the down swing phase was $0.28{\pm}0.056sec$ and the total swing time was $0.825{\pm}0.017sec$ 2. The maximum linear velocity of the stick blade for x direction was shown after 7% of impact, for y, z direction were shown before 2%, 8% of Impact. 3. The maximum velocity of each segment for the left arm was $2.35{\pm}0.05m/s$ in the upper arm, $3.56{\pm}0.34m/s$ in the forearm, $4.75{\pm}0.67m/s$ in the hand. 4. The maximum velocity of each segment for the right arm was $4.67{\pm}0.43m/s$ in the upper arm, $7.22{\pm}0.69m/s$ in the forearm, $9.42{\pm}0.89m/s$ in the hand. 5. The angle of left elbow was generally flexed from the ready stance to the impact and was $82.26{\pm}3.45^{\circ}$ the moment of Impact. 6. The angle of the left shoulder was increased ut the down swing phase and was $78.74{\pm}4.78^{\circ}$ on the moment of impact. 7. The angle of the right shoulder was decreased in the down swing phase and increased before the impact. and the angle was $51.28{\pm}3.54^{\circ}$ on the moment of impact.

Electromyographical Analyses of Muscle Activities of Upper Trunk for Ssireum Dutguri Technique (Electromyography 기법을 이용한 씨름 덧걸이 기술의 상체 근 동원 비교분석)

  • Shin, Sung-Hyu;Lim, Young-Tae;Kim, Tae-Hwan;Park, Ki-Ja;Kwon, Moon-Suk
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.95-108
    • /
    • 2003
  • The purposes of this study were to analyze the muscle activities and the characteristics of muscle recruiting patterns of upper trunk for Ssirum dutguri technique using three top-ranked elite Ssirum players. The EMG technique was used to record muscle activities of both right and left sides of latissimus dorsi, biceps brachii, and erector spinae. Six surface electrodes were placed on the surface of the selected muscles and one ground electrode was also attached on the back of neck(C7). One video camera was also used to record the Ssirum motion to define 4 events and 3 phases for further analysis. The raw EMG data were filtered with band pass filter (50-400 Hz) to remove artifacts and then low pass filtered (4 Hz) to find the linear envelope which resemble muscle tension curve. This filtered EMG data were normalized to MVIC for the purpose of comparion between the subjects. The results were indicated that each subject with different physical characteristics showed very different muscle activity patterns. Although Ssirum dutguri is considered as foot technique the player grasped opponent's satba(belt) with both hands when they play. Because of this reason, activities of upper trunk muscles were relatively high. However, direct comparison between upper and lower body muscles was not possible due to the lack of the data in present study. Interestingly, all threes subjects showed that erector spinae muscle activity was comparatively higher than those of latissimus dorsi and biceps brachii. This implies to reinforce back muscle as a routine of training to improve performance or to prevent back injury.

A Development of an Insole Type Local Shear Measurement Transducer and Measurements of Local Plantar Shear Force During Gait (인솔형 국부 전단센서의 개발 및 보행 시 발바닥의 국부 전단력 측정)

  • Jeong Im Sook;Ahn Seung Chan;Yi Jin Bok;Kim Han Sung;Kim Young Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.213-221
    • /
    • 2005
  • An insole type local shear force measurement system was developed and local shear stresses in the foot were measured during level walking. The shear force transducer based on the magneto-resistive principle, was a rigid 3-layer circular disc. Sensor calibrations with a specially designed calibration device showed that it provided relatively linear sensor outputs. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Sensor outputs were amplified, decorded in the bluetooth transmission part and then transferred to PC. In order to evaluate the developed system, both shear and plantar pressure measurements, synchronized with the three-dimensional motion analysis system, were performed on twelve young healthy male subjects, walking at their comfortable speeds. The maximum peak pressure during gait was 5.00kPa/B.W at the heel. The time when large local shear stresses were acted correlated well with the time of fast COP movements. The anteroposterior shear was dominant near the COP trajectory, but the mediolateral shear was noted away from the COP trajectory. The vector sum of shear stresses revealed a strong correlation with COP movement velocity. The present study will be helpful to select the material and to design of foot orthoses and orthopedic shoes for diabetic neuropathy or Hansen disease.

Application of Adaptive Control for the U Type TLD (U자형 TLD시스템에 대한 적응제어 적용)

  • Ga, Chun-Sik;Shin, Young-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.518-521
    • /
    • 2005
  • The Structures or buildings nowadays draw more complexity in design due to space limitation and other factor that affect the height and dimensions, that results to instability. So the various methods have been carried out to improve the safety factor from an earthquake or a boom until recently. But, it is very hard to get model precisely because these structures are the non-linear and multi-variable systems. For this reason, we developed the active control system that is applied the adaptive control method on the U type Tuned Liquid Damper(TLD) passive control system. It is proven that the proposed active control strategy of the plate carrying U type TLD system is the more effective control method to suppress the vibration of the structure. The entire hybrid control system is composed of the actuator acted in the opposite direction of the TLD system's motion direction and the active control device with an air pressure adjuster. This paper proposed the adaptive control methods to improve the problem of U type TLD system which is used widely for the passive control of the building. And it is proved by the simulation. In advanced, it is developed the pressure control method that is improved the hybrid controller's performance by using air chamber pressure controller. These methods take the advantage of the decrease of the maximum displacement by using the controller as soon as the impact is loaded. This is a very important element for the safety design and economic design of structures.

  • PDF

Investigating the effects of ultra-rapid, rapid vs. final precise orbit and clock products on high-rate GNSS-PPP for capturing dynamic displacements

  • Yigit, Cemal O.;El-Mowafy, Ahmed;Bezcioglu, Mert;Dindar, Ahmet A.
    • Structural Engineering and Mechanics
    • /
    • v.73 no.4
    • /
    • pp.427-436
    • /
    • 2020
  • The use of final IGS precise orbit and clock products for high-rate GNSS-PPP proved its effectiveness in capturing dynamic displacement of engineering structures caused by earthquakes. However, the main drawback of using the final products is that they are available after approximately two weeks of data collection, which is not suitable for timely measures after an event. In this study, the use of ultra-rapid products (observed part), which are available after a few hours of data collection, and rapid products, which are available in less than 24 hrs, are investigated and their results are compared to the more precise final products. The tests are designed such that harmonic oscillations with different frequencies and amplitudes and ground motion of a simulated real earthquake are generated using a single axis shake table and the PPP was used to capture these movements by monitoring time-change of the table positions. To evaluate the accuracy of PPP using ultra-rapid, rapid and final products, their results were compared with relative GNSS positioning and LVDT (Linear Variable Differential Transformer) data, treated as reference. The results show that the high-rate GNSS-PPP solutions based on the three products can capture frequencies of harmonic oscillations and dynamic displacement with good accuracy. There were slight differences between ultra-rapid, rapid and final products, where some of the tested events indicated that the latter two produced are more accurate and provide better results compared to the ultra-rapid product for monitoring short-term dynamic displacements.

Investigation of Sensor Models for Precise Geolocation of GOES-9 Images (GOES-9 영상의 정밀기하보정을 위한 여러 센서모델 분석)

  • Hur, Dong-Seok;Kim, Tae-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.4
    • /
    • pp.285-294
    • /
    • 2006
  • A numerical formula that presents relationship between a point of a satellite image and its ground position is called a sensor model. For precise geolocation of satellite images, we need an error-free sensor model. However, the sensor model based on GOES ephemeris data has some error, in particular after Image Motion Compensation (IMC) mechanism has been turned off. To solve this problem, we investigated three sensor models: collinearity model, direct linear transform (DLT) model and orbit-based model. We applied matching between GOES images and global coastline database and used successful results as control points. With control points we improved the initial image geolocation accuracy using the three models. We compared results from three sensor models. As a result, we showed that the orbit-based model is a suitable sensor model for precise geolocation of GOES-9 Images.