• Title/Summary/Keyword: Linear infiltration system

Search Result 8, Processing Time 0.025 seconds

A case study about exterior space design of apartments using Linear infiltration system (선형침투시스템의 공동주택 외부공간 적용 방안 연구)

  • Moon, Soo-young;Kim, Hyeon-soo;Jang, Dae-hee;Lee, Keon-ho
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2007
  • As environmental problems and water-shortage phenomenon become a global issue, many states look for the effective method to use water resources. So, decentralized rainwater management is recognized as a new water management system that rainwater can be infiltrated and used on-site. But it is little difficult to build a park, lake, and forest for evaporating rainwater in city because the land price of city is very high. In order to build an excellent infiltration system for a dwelling and a park in Korea, KICT has developed Linear infiltration system. This infiltration system is consist of first flush treatment, storage and infiltration, overflow control system. These elements are connected closely and working as a combined system. A storm sewer can be changed by the linear infiltration system. This study is to show real application idea about Linear infiltration system with improving some detail in apartments. For this purpose, we devide application idea into the artificial ground and the natural ground and each ground type, suggest a method to cooperate with the other landscape and linear infiltration system. Through this study, we came to recognize a recognition difference of an expert and a commoner about decentralized rainwater management.

A comparative study of design guidelines for the decentralized rainwater management of apartment house (분산식 빗물관리를 위한 공동주택 외부공간 설계지침 연구)

  • Moon, Soo-young;Kim, Hyeon-soo;Lee, Keon-ho;Jang, Dae-hee
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.3-10
    • /
    • 2006
  • As environmental problems and water-shortage phenomenon become a global issue, many states look for the effective method to use water resources. So, decentralized rainwater management is recognized as a new water management system that rainwater can be infiltrated and used on-site. But it is little difficult to build a park, lake, and forest for evaporating rainwater in city because the land price of city is very high. In order to build an excellent infiltration system for a dwelling and a park in Korea, KICT has developed Linear infiltration system. This infiltration system is consist of first flush treatment, storage and infiltration, overflow control system. These elements are connected closely and working as a combined system. A storm sewer can be changed by the linear infiltration system. This study is to make design guideline using Linear infiltration system in apartment house. So ATV-DVWK-M13, FLL and present condition of Korean rainwater system were analyzed and the guidelines direction were set up. Through this study, a foundation is prepared to build the decentralized rainwater management of apartment house.

In-situ Structure Modification of W powder Skeleton and related Cu Infiltration Kinetics in W-Cu (W-Cu 계에서 W 분말골격의 in-situ 구조 변화와 Cu의 용침 kinetics)

  • 이재성
    • Journal of Powder Materials
    • /
    • v.6 no.1
    • /
    • pp.36-41
    • /
    • 1999
  • The present work has attempted to investigate the dependence of Cu infiltration kinetics on in-situ structure modification of W powder skeleton in W-Cu system. In-situ structure modification of W skeleton by addition of 0.3wt%Ni-P eutectic alloy was designed to proceed during heat-up of the W compact for Cu infiltration process. It was found that the Ni-P added W skeleton underwent remarkable stucture change only during heating-up. its structure was composed of large necks of W particles above 0.5 in the ratio of neck to particle size and smooth pore channels. The infiltration experiment showed that the infiltration kinetics for the W-Ni-P followed well the linear relationship of h vs. $t^{1/2}$ the rate constant K of which was in good agreement with the theoretical value. On the other hand, in case of the pure W skeleton a lower K value by 20% than the theoretical one was obatined. Such discrepancy is discussed in terms of skeleton structure induced infiltration mechanics.

  • PDF

Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters (라돈 환경계통의 제어 매개변수 모델링)

  • Zoo, Oon-Pyo;Kim, Kem-Joong;Chang, Si-Young
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

Quantitative Analysis of Epicardial fat (심외막 지방의 정량분석)

  • O, Jung-Hwan;Gang, Cheong-Hui;Lee, Jong-Guk
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.233-236
    • /
    • 1995
  • Subepicardial space is one of the regions in which fat in moderate amount is normally deposited. When excess deposits of epicardial fat occur, penetration or infiltration of fat into the connective tissues between muscle bundles is observed. In some cases with very extensive involvement of epicardial fat,myocardial insufficiency and conduction system defect such as heart block have been implicated. More fat is deposited over the right ventricle than over left and the anterior surface contains more fat than dose the posterior surface. We studied 40 patients who underwent open heart surgery under the cardiopulmonary bypass. This study was designed to evaluate the percentage of the area of epicardial fat of the right ventricular anterior surface, which is more accessible area during the operative procedure. Other variables included thickness of subcutanous tissue of anterior chest wall, the ratio of waist to hip circumference, body weight and age. In conclusion, the amount of the epicardial fat correlates with thickness of the subcutaneous fat of the anterior chest wall and simple linear regression analysis indicates good correlation with body weight. Increased age results in large amount of epicardial fat.

  • PDF

Modeling the Controllable Parameters of Radon Environment System with Dose Sensitivity Analysis (실내 라돈환경계의 선량감도분석에 의한 제어매개변수 모델링)

  • Zoo, Oon-Pyo;Chang, Yi-Young;Kim, Kern-Joong
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.41-54
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of indoor radon $(^{222}Rn)$ and its decay products (Rn-D) by applying the input~output linear system theory. Physical behaviors of $^{222}Rn\;&\;Rn-D$ were analyzed in terms of $(^{222}Rn)$ gas -generation, -migation and -infiltration to indoor environments, and the performance output-function, i. e. mean dose equivalent to Tracho-Bronchial (TB) lung region, was assessed to the following extented ranges of the controllable paramenters; a) the ventilation rate $constant({\lambda}_v)\;:\;0{\sim}50[h^{-l}].\;b)$ the attachment rate $constant({\lambda}_a)\;:\;0{\sim}500[h^{-l}].\;c)$ the unattached-deposition rate constant (${\lambda}^u_d)\;:\;0-50[h-l]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations; a) indoor $^{222}Rn\;&\;Rn-D$ Behaviour; Jacobi-Porstendoerfer-Bruno model.

  • PDF

ROC Analysis of Simulated Chest Lesions for Computed Radiography and Digital Radiography at Various Tube Voltages (다양한 관전압에 따른 CR과 DR 모의병변 흉부 영상의 ROC 평가)

  • Cho, Hyo-Min;Kim, Hee-Joung;Lee, Chang-Lae;Jung, Ji-Young;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.298-304
    • /
    • 2008
  • Current digital radiographic systems are rapidly growing in clinical applications. The purpose of this study was to evaluate the diagnostic performance of computed radiography (CR) and digital radiography (DR) at different tube voltages in the detection of simulated chest lesions. Patterns of simulated interstitial lung disease, incipient infiltration, and nodules were superimposed over an anthropomorphic chest phantom. A simulated chest phantom radiograph was obtained with CR and DR at different tube voltages (70 kV, 90 kV, and 120 kV). A total of 18,000 observations were analyzed using a receiver operating characteristic (ROC) analysis. The detection of all lesions showed higher $A_z$ values at 70 kV than 120 kV with CR. For the DR, mean $A_z$ values at 70 kV were higher than other tube voltages not all lesions but for micro-nodule interstitial lung disease, linear interstitial lung disease, and incipient infiltration. Based on these results, a clinical study should be performed to judge the use of suitable tube voltage according to the type of detector system and lesions.

  • PDF

Development of Grid Based Distributed Rainfall-Runoff Model with Finite Volume Method (유한체적법을 이용한 격자기반의 분포형 강우-유출 모형 개발)

  • Choi, Yun-Seok;Kim, Kyung-Tak;Lee, Jin-Hee
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.895-905
    • /
    • 2008
  • To analyze hydrologic processes in a watershed requires both various geographical data and hydrological time series data. Recently, not only geographical data such as DEM(Digital Elevation Model) and hydrologic thematic map but also hydrological time series from numerical weather prediction and rainfall radar have been provided as grid data, and there are studies on hydrologic analysis using these grid data. In this study, GRM(Grid based Rainfall-runoff Model) which is physically-based distributed rainfall-runoff model has been developed to simulate short term rainfall-runoff process effectively using these grid data. Kinematic wave equation is used to simulate overland flow and channel flow, and Green-Ampt model is used to simulate infiltration process. Governing equation is discretized by finite volume method. TDMA(TriDiagonal Matrix Algorithm) is applied to solve systems of linear equations, and Newton-Raphson iteration method is applied to solve non-linear term. Developed model was applied to simplified hypothetical watersheds to examine model reasonability with the results from $Vflo^{TM}$. It was applied to Wicheon watershed for verification, and the applicability to real site was examined, and simulation results showed good agreement with measured hydrographs.