• 제목/요약/키워드: Linear attenuation coefficient

검색결과 79건 처리시간 0.024초

Development of high-performance heavy density concrete using different aggregates for gamma-ray shielding

  • Ouda, Ahmed S.
    • Advances in materials Research
    • /
    • 제3권2호
    • /
    • pp.61-75
    • /
    • 2014
  • This study aimed to investigate the suitability of some concrete components for producing "high-performance heavy density concrete" using different types of aggregates that could enhances the shielding efficiency against ${\gamma}$-rays. 15 mixes were prepared using barite, magnetite, goethite and serpentine aggregates along with 10% silica fume, 20% fly ash and 30% blast furnace slag to total OPC content for each mix. The mixes were subjected to compressive strength at 7, 28 and 90 days. In some mixes, compressive strengths were also tested up to 90 days upon replacing sand with the fine portions of magnetite, barite and goethite. The mixes containing magnetite along with 10% SF reaches the highest compressive strength exceeding over M60 requirement by 14% after 28 days. Whereas, the compressive strength of concrete containing barite was very close to M60 and exceeds upon continuing for 90 days. Also, the compressive strength of high-performance concrete incorporating magnetite fine aggregate was significantly higher than that containing sand by 23%. On the other hand, concrete made with magnetite fine aggregate had higher physico-mechanical properties than that containing barite and goethite. High-performance concrete incorporating magnetite fine aggregate enhances the shielding efficiency against ${\gamma}$-rays.

전산화 단층촬영에 의한 오링 변형 거동 분석 (Analysis of the O-ring Deformation Behavior by the Computed Tomography)

  • 김동륜;박성한;이환규;구형회
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.25-29
    • /
    • 2006
  • 본 연구는 가압상태에서 오링 변형 거동을 측정하기 위한 새로운 시험 기법을 개발하기 위함이다. 전산화 단층촬영으로 압출 틈에서 측정한 압출 길이와 비접촉 레이저 변위 센서로 측정한 압출 길이는 결과가 일치하였다. 전산화 단층촬영에서 측정한 변형된 오링 형상과 유한요소법으로 해석하여 얻은 오링 형상은 압출 길이와 확장 지름은 일치하였으나, 오링과 스틸의 접촉 길이는 전산화 단층촬영의 결과가 유한요소해석의 결과보다 약간 크게 측정되었다.

  • PDF

전산화 단층촬영에 의한 니들펀칭 탄소/탄소 복합재료 노즐 목삽입재의 밀도 분포 평가 (Density Profile Evaluation of Needle-punched Carbon/Carbon Composites Nozzle Throat by the Computed Tomography)

  • 김동륜;윤남균;이진용
    • 한국추진공학회지
    • /
    • 제10권1호
    • /
    • pp.44-53
    • /
    • 2006
  • 전산화 단층촬영법을 이용하여 탄소/탄소 목삽입재의 밀도 분포를 평가하였다. 전산화 단층촬영법의 Team hardening, 전기적 잡음 및 산란 X-ray의 영상을 보정하고 신호 대 잡음비를 높여 최적화할 때 측정된 탄소/탄소 복합재료의 밀도는 98.74%의 신뢰도 수준에서 ${\pm}0.01g/cm^3$ 분포를 갖는 것으로 평가되었다. 전산화 단층촬영 결과의 검증은 탄소/탄소 목삽입재를 절단하여 수침법에 의한 밀도 측정과 주사전자현미경 관찰을 통하여 수행되었으며 단층촬영 결과는 수침법에 의한 밀도 분포와 주사전자현미경의 영상과 일치하였다.

Impacts of the calcination temperature on the structural and radiation shielding properties of the NASICON compound synthesized from zircon minerals

  • Islam G. Alhindawy;Hany Gamal;Aljawhara.H. Almuqrin;M.I. Sayyed;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1885-1891
    • /
    • 2023
  • The present work aims to fabricate Na1+xZr2SixP3-xO12 compound at various calcination temperatures based on the zircon mineral. The fabricated compound was calcinated at 250, 500, and 1000℃. The effect of calcination temperature on the structure, crystal phase, and radiation shielding properties was studied for the fabricated compound. The X-ray diffraction diffractometer demonstrates that, the monoclinic crystal phase appeared at a calcination temperature of 250℃ and 500℃ is totally transformed to a high-symmetry hexagonal crystal phase under a calcination temperature of 1000℃. The radiation shielding capacity was also qualified for the fabricated compounds using the Monte Carlo N-Particle transport code in the g-photons energy interval between 15keV and 122keV. The impacts of calcination temperature on the g-ray shielding behavior were clarified in the present study, where the linear attenuation coefficient was enhanced by 218% at energy of 122keV, when the calcination temperature increased from 250 to 1000℃, respectively.

60 GHz 대역 전력 증폭기를 위한 구간별 차등 다항식 모델 기반의 디지털 사전왜곡기 설계 (Design of A Piecewise Polynomial Model Based Digital Predistortion for 60 GHz Power Amplifier)

  • 김민호;이진구;김대현;김영록
    • 전자공학회논문지
    • /
    • 제53권5호
    • /
    • pp.3-12
    • /
    • 2016
  • 최근 들어, 밀리미터파 대역을 활용하는 5세대 이동 통신 시스템에 대한 연구가 활발히 진행되고 있으며, 밀리미터파 대역의 전파 감쇠 특성으로 인하여 전력 증폭기의 비선형성을 완화시키는 방법의 중요성이 증가하고 있다. 본 논문에서는 전력 증폭기의 특성을 선형구간과 비선형구간을 구분하여 구간별 계수를 사용하는 구간별 차등 다항식 모델을 제안하였다. 또한, 제안된 모델과 직접 학습 방식을 이용하여 디지털 사전왜곡기 구현 방안을 제시하였다. 제안된 모델의 성능을 검증하기 위하여 LTE 신호를 인가한 60 GHz 대역 전력증폭기를 위한 제안된 모델과 직접 학습 방식에 기반한 디지털 사전왜곡기를 FPGA로 구현하였고 하드웨어 테스트벤치를 통하여 성능 및 연산 복잡도를 비교 검증하였다. 제안된 모델은 기존 단일 다항식 모델 대비 ACLR 측면에서는 3.3 dB 개선됨을 보였으며 연산 복잡도 측면에서는 7.5 % 감소됨을 보여주었다

Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation

  • Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1077-1088
    • /
    • 2018
  • Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.

조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 - (A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province)

  • 양정화;이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.63-69
    • /
    • 2006
  • 초음파 영상의 질은 진단에 많은 영향을 끼친다. 양질의 영상이 항상 일정하게 유지되기 위해서는 QA(Quality Assurance) 프로그램을 가지고 주기적인 관리가 이루어져야 할 것이다. 본 논문은 임상에서의 QA 상황을 파악하는 첫 번째 단계로 실제 병원의 초음파 영상의 질을 살펴보고자 하였다. 이를 위해 인간의 생체등가물질로 된 팬텀을 이용하여 정상 환자를 스캔할 때와 같은 기준 값에서 가상의 낭포 및 고반사 신호의 구조물들이 몇 개가 보이는지 convex probe와 linear probe를 측정하여 비교하였다. convex probe에서는 정상 간과 비슷한 0.5 dB에서 vertical group, cystic masses, high contrast masses에서는 대부분 잘 보였으며 지방간과 비슷한 조건인 0.7 dB에서는 vertical group이 중간레벨에서, cystic masses와 high contrast masses에서는 대체로 모두 잘 보였다. linear probe에서의 vertical group은 0.5 dB에서 중간레벨만 잘 보였고 cystic masses와 high contrast masses는 두 개에서 네 개 보이는 것들이 고루 분포되었으나 하나도 보이는 않는 경우가 11건수나 되었다. 0.7 dB에서는 vertical group이 6개 이하가 보이는 것이 대부분 이었고 cystic masses와 high contrast masses에서도 두개에서 네 개 보이는 것들이 고루 분포되었고 하나도 보이는 않는 경우도 40건 있었다. 이로서 지방간과 같은 조건하에서는 linear probe의 영상의 질이 대체로 좋지 않으므로 기준 설정 및 물리적인 조건들을 검사 시에 잘 조정하거나 probe의 교체가 필요하다고 판단된다. 많은 병원에서 초음파 장비를 잘 관리하고 있다고 하지만, 영상의 질은 아직도 미흡한 것을 알 수 있다. 초음파 장비의 설치에서부터 영상의 질을 평가하고 지속적이고 정기적인 관리와 평가가 이루어질 수 있는 프로그램이 필요하겠다.

  • PDF

다중채널 표면파 자료를 이용하여 구한 S파 속도와 감쇠지수 구조: 낙동강 하구의 연약 지반 특성 (S-wave Velocity and Attenuation Structure from Multichannel Seismic surface waves: Geotechnical Characteristics of NakDong Delta Soil)

  • 정희옥
    • 한국지구과학회지
    • /
    • 제25권8호
    • /
    • pp.774-783
    • /
    • 2004
  • 다중채널 탄성파 자료를 이용하여 낙동강 하구 삼각주 지역 연약지반의 지반 특성을 구하기 위하여 S파 속도와 Q$s^{-1}$ 구조를 구하고 이를 시추조사 결과와 비교하였다. 다중채널 신호의 분산곡선을 역산하여 S파 속도구조를 구하고 감쇠지수(attenuation coefficient)를 구하였다. 다중채널 신호 중 음원에서 가장 가까운 신호를 기준 신호로 정하고 10 Hz에서 45 Hz 사이의 주파수에 대하여 거리에 따라 기준 신호에 대한 진폭의 비가 감소하는 정도를 나타내는 기울기를 구하여 감쇠지수를 결정하였다. 이 감쇠지수를 역산하여 지반 최상부 8 m 층의 S파 속도와 함께 Q$s^{-1}$를 구하였다. 이 지역의 시추조사에 의하면 이 지역의 지층은 크게 상부 4 m 실트질 모래층과 하부 4 m 실트질 점토층으로 나누어진다. 표면파 역산에 의해 구해진 S파 속도와Q$s^{-1}$를 시추조사 결과와 비교해보면, 상부 실트질 모래층에서 S파 속도의 공간적 해상도는 약 80m/sec로 하부 실트질 점토층의 속도 40m/sec보다 상대적으로 높은 값을 보인다. 각 층에서 S파 속도의 공간적 해상도는 뚜렷하다. Q$s^{-1}$의 공간구조는 상부 실트질 모래층에서 약 0.02를 보이고 하부 실트질 점토층에서 0.03으로 증가하는 양상을 보인다. Q$s^{-1}$의 공간적 해상도는 상부 약 5 m 구간에서는 양호하나 그 보다 깊은 곳에서는 공간적 해상도가 아주 낮아지는 것을 볼 수 있다. 이 조사지역에서는 실트질 모래층에서 실트질 점토층보다 높은 S파 속도가 나타나고 낮은 Q$s^{-1}$ 값을 보인다. 그러나, 지반의 S파 속도와 Q$s^{-1}$를 결정하는 다른 많은 요인들이 있으므로 이를 일반화하기 위해서는 연약지반의 S파 속도와Q$s^{-1}$에 관한 자료와 연구가 집적되어야 할 것이다.

PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가 (The Effects of a MR Torso Coil on CT Attenuation Correction for PET)

  • 이승재;반영각;오신현;강천구;임한상;김재삼;이창호;서수현;박용성
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.81-86
    • /
    • 2012
  • PET과 융합된 MR 영상에서 MR coil은 PET 영상용 감쇄보정에 있어서 위치 정보 수집에 관한 오류를 극복하기 위한 노력이 시도 되어 왔다. 본원에서는 이런 문제점을 보완한 Three modality system (PET/CT +MR)을 이용하고 있다. 이 논문에서는 MR torso coil이 CT 감쇄보정에 미치는 영향을 평가하였다. MR torso coil을 장착하고 CT로 감쇄보정한 PET 영상에서 인공물에 대한 평가를 하였다. 균일도 평가용 팬텀과 1994 NEMA 실린더 팬텀을 사용하여, CT의 관전압과 관전류를 변경해가며 표준화섭취계수에 대한 변화를 추적하였다. MR torso coil안에 있는 금속 물질로 인한 줄무늬 인공물이 관찰되었다. CT 검사에 있어서 관전압과 관전류를 변화 시키면 선 감쇄계수도 일정하게 변화하였다. 관전압과 관전류의 수치가 높아짐에 따라 PET 영상에서의 표준화섭취계수가 증가하는 것을 볼 수 있었다. PET/CT 검사 시, MR torso coil은 금속으로 인한 줄무늬 인공물을 생성하며, 감쇄보정에 있어서 잠재적인 오류를 불러올 수 있다. 이와 같은 오류를 감소시키기 위해서는 첫째, 감쇄보정 알고리즘의 보완, 둘째, MR coil을 사용하지 않은 검사방법의 연구, 셋째, PET/CT 감쇄보정에 영향을 주지 않는 MR coil소재의 개발 등이 요구된다.

  • PDF

Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.65-75
    • /
    • 1971
  • 국내에서 산출되는 각종 광물골재를 사용하여 방사선 차폐용 중차폐 콩크리트를 제조하고 감마선에 대한 차폐 효과를 실험한 결과 최적하다고 판단된 자철광 중차폐 콩크리트를 대상으로 60Co 감마선의 Broad beam을 사용하여 방사선 차폐 효과를 측정하였다. 본 실험을 통하여 실험적으로 차폐체내의 방사선의 감쇄곡선으로부터 차폐 체 두께의 변화에 따르는 방사선 투과율과의 상호관계에 관한 수식을 다음과 같이 유도해냈다. I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$$10^{-1}$X-3.38$\times$$10^{-3}$X$^2$+5.29$\times$$10^{-5}$X$^3$) X< 20 cm 때, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$$10^{-2}$ X+2.12$\times$$10^{-1}$) X>20 cm 때. 이와같이 얻은 결과식에서 오른쪽 첫번째항은 최초 감마선의 감쇄를 표시하고 그 다음항은 차폐체 내에서의 감마선 재생계수를 나타낸다. 이 실험에 첨가하여 차폐체의 실제 설계에 입각한 입방형 자철광 구조체 (두께 8 cm, 내부공간 40$\times$40$\times$40cm)에 대한 차폐효과를 측정한 결과 평판 차폐체를 사용할 때 보다 투과 방사선이 증가됨을 알았다.

  • PDF