• Title/Summary/Keyword: Linear Variable Differential Transformer

Search Result 44, Processing Time 0.025 seconds

A Compensation Technique of the Linearity Error of Linear Variable Differential Transformer (선형변이 차동변압기 센서의 직선성오차 보정기법)

  • Choi, Ju-Ho;Hwang, Eui-Seong;Hong, Sung-Soo;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.1
    • /
    • pp.51-56
    • /
    • 2000
  • This paper presents the characteristics of the dynamic response and calibration technique on a linear variable differential transformer(LVDT). The linear error of the LVDT was proven $\pm$1% in the static calibration and $\pm$0.5% in the dynamic calibration. In this paper, the linearity error generated in the static and dynamic state of the core movement can be eliminated using the correction algorithem of the static and dynamic state derived from the least square linear approximation for the nonlinearity of the curves of direct data fitting and Lagrange polynomials. With the static and dynamic calibration method, the calibration accuracy of the LVDT can be reduced to within $\pm{0.5%.}$.

  • PDF

A Development of Recoil & Counter Recoil Motion Measurement System Using LVDT

  • Park, Ju-Ho;Hong, Sung-Soo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.3
    • /
    • pp.214-219
    • /
    • 2000
  • This paper presents a recoil and counter recoil motion measurement system using linear variable differential transformers (LVDT). The output of the LVDT is obtained from the differential voltage of the secondary transformers. Since a transducer core is attached to the motion body, the output is directly proportional to the movement length of the core. Displacement, velocity and acceleration are measured from the LVDT. With a comparison between the measurement result and the reference value obtained by the highly accurate Vernier calipers, it is proved that the measurement system with the LVDT is applicable to the test of the moving part of the mechanism with better accuracy.

  • PDF

Feasibility Study of Structural Behavior Monitoring Using GPS and Accelerometer (GPS와 가속도계를 이용한 구조물 거동모니터링의 타당성 연구)

  • Han, Jung Hun;Ryu, Sung Chan;Cho, Doo Yong;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.11-22
    • /
    • 2012
  • In this study, problems of RTK (Real Time Kinematic)-GPS (Global Positioning System) and an accelerometer sensor when applied to structures were experimentally identified through a comparison between results of the displacement measurement using the RTK-GPS, the accelerometer, and LVDT (Linear variable differential transformer). Integrated displacement was calculated by the improved RTK-GPS and accelerometer on the frequency of observation and positioning accuracy. This integrated displacement was also compared with that of LVDT to check the validity of application and feasibility.

EFFECT OF FIBER DIRECTION ON THE POLYMERIZATION SHRINKAGE OF FIBER-REINFORCED COMPOSITES (섬유 보강 복합레진의 섬유 방향이 중합수축에 미치는 영향)

  • Yom, Joong-Won;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.364-370
    • /
    • 2009
  • The aim of this study was to evaluate the effect of fiber direction on the polymerization shrinkage of fiber-reinforced composite. The disc-shaped flowable composite specimens (d = 10 mm, h = 2 mm, Aeliteflo A2, Bisco, Inc., IL, USA) with or without glass fiber bundle (X-80821P Glass Fiber, Bisco, Inc., IL, USA) inside were prepared, and the longitudinal and transversal polymerization shrinkage of the specimens on radial plane were measured with strain gages (Linear S-series 350${\Omega}$, CAS, Seoul, Korea). In order to measure the free polymerization shrinkage of the flowable composite itself, the disc-shaped specimens (d = 7 mm, h = 1 mm) without fiber were prepared, and the axial shrinkage was measured with an LVDT (linear variable differential transformer) displacement sensor. The cross-section of the polymerized specimens was observed with a scanning electron microscope to examine the arrangement of the fiber bundle in composite. The mean polymerization shrinkage value of each specimen group was analyzed with ANOVA and Scheffe post-hoc test (${\alpha}$=0.05). The radial polymerization shrinkage of fiber-reinforced composite was decreased in the longitudinal direction of fiber, but increased in the transversal direction of fiber (p<0.05). We can conclude that the polymerization shrinkage of fiber-reinforced composite splint or restoratives is dependent on the direction of fiber.

Measuring Inside Diameter with Electronic Micrometer (전기 마이크로미터를 이용한 내경측정)

  • 이헌민;배영주;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.491-494
    • /
    • 1995
  • In this study, we presented a system to measure inside diameters of parts of compressor. This system solved problems of air micrometer and improved measurement accuracy by using linear variable differential transformer. The system was designed for production line which require accurate and reliable measuring system. And the system is easier and faster to use than air micrometer and can be applied various measuring area.

  • PDF

Solvent-induced Expansion & Shrinkage of Demineralized Dentin Matrix

  • Lee, Kwang-Won
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.580-580
    • /
    • 2001
  • Before resin composites can serve as durable substitutes for amalgam restorations, the adhesive system used to retain them and add to seal dentin must be improved. The recent observations, using the newly developed LVDT (linear variable differential transformer) probe, that all commercial bonding systems cause a collapse of the demineralized dentin matrix, simulated a re-evaluation of the effects of these formulations on the matrix. The experiment was begun by examining solvents such as water-HEMA mixtures. These produced the same shrinkages as did the complete formulations.(omitted)

  • PDF

The Analysis is on the Performance Characteristics for Design of a Linear Variable Differential Transformer (LVDT) (LVDT 설계를 위한 특성해석)

  • Park, Y.T.;Shin, H.G.;Jeong, Y.H.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.60-62
    • /
    • 1994
  • In this paper, the LVDT with compensating secondary coil and secondary current boost circuit is proposed. The LVDT was experiment with a test device, and analyzed with numerical method (FEM), It is shown that the LVDT has a good linearities for the measurement of the displacement and position, etc..

  • PDF

Applying DSLR Camera for Measuring the Deflection of Concrete Beam (DSLR 카메라를 활용한 콘크리트 보의 변형 측정)

  • Lee, Byoung-Kil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • Measurements of deflection in load testing of structures are typically obtained with contact instrumentations such as LVDT (Linear-Variable Differential Transformer). LVDT only measure 1-dimensional deformation and in destructive testing is damage to instrumentation, thus prohibiting deflection when the beam is close to failure. Measurements of deflection using non-metric digital cameras are useful for load testing because there are very little cost or beam failure except for cheap targets and measurements in 3-dimensional deflection can obtained rapidly. In this research, deflection of concrete beam was measured using Nikon D80 DSLR camera, and the accuracy was evaluated with comparing the outputs to the LVDT measurements. The results show that the accuracy of terrestrial photogrammetric measurements are ${\pm}$0.5mm, ${\pm}$0.5mm, ${\pm}$0.6mm for each X, Y, Z directions, and the RMSE of comparison to LVDT is ${\pm}$0.57mm.