• 제목/요약/키워드: Linear Scanner

검색결과 130건 처리시간 0.025초

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

지상 라이다를 활용한 현황측량 연구 (The Study on Reconnaissance Surveying Using Terrestrial Laser Scanner)

  • 이인수;강상구
    • 대한공간정보학회지
    • /
    • 제14권3호
    • /
    • pp.79-86
    • /
    • 2006
  • 현재 3차원 지상 레이저 스캐너를 통해서 짧은 시간에 대상물의 수많은 위치에 대한 고정도의 3차원 좌표를 얻을 수 있다. 그래서 최근에 지상 레이저 스캐닝은 측지분야를 포함하여 토목공학, 고고학 및 건축, 그리고 응급서비스 및 국방, 기타 등 다양한 분야에서 널리 응용되고 있다. 본 연구는 지상 라이다를 이용한 현황측량을 다루었으며, 실험측량 결과 대상물의 선형 특징추출이 가능하였으며 토탈스테이션 측량성과에 필적하는 위치결정 정확도를 얻었다. 이를 통해 향후 항공 라이다와 항공사진측량기술과의 결합에 의해 지상 레이저 스캐닝의 잠재응용분야는 더욱 증대될 것으로 기대된다.

  • PDF

분할된 색공간에서 비선형 다중회귀분석법을 이용한 스캐너 켈리브레이션에 관한 연구 (A study on scanner calibration method using nonlinear regression analysis in sub-divided color space)

  • 김나나;구철회
    • 한국인쇄학회:학술대회논문집
    • /
    • 한국인쇄학회 2000년도 추계학술발표회 논문집
    • /
    • pp.0.2-0
    • /
    • 2000
  • Most important step for the color matching in scanner is the color coordinate transformation from the scanner RGB space to device independent uniform color space. A variety of color calibration technologies have been developed for input device. Linear or nonlinear matrices have been conveniently applied to correct the color filter\`s mismatch with color matching function in scanners. The color matching accuracy is expected to be further improved when the nonlinear matrices are optimized into subdivided smaller color spaces than in single matrix of the entire color space. This article proposed the scanner calibration method using subspace division regression analysis and it were compared with conventional method.

  • PDF

초음파 B스캔너의 개발(I) -시스템 및 아나로그부분- (Development of Ultrasound B-scanner(I)-System and Analog Part-)

  • 김진하;신동희
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.77-84
    • /
    • 1984
  • A prototype of a linear real-time ultrasound B-scanner has been developed which has an axial resolution of 1-2mm and lateral resolution of 2-3mm. In the actual hardware and software implementations of the B-scanner, the following features were emphasized; (1) a dynamic focusing to improve resolution; (2) signal processing to obtain low noise image; (3) various functions for the user's convenience' (4) simplification of the system by an extensive use of recently developed LSI's; (5) development of a prototype at the level of a commercial product. This paper reports the experimental results of the overall system and the design approach of the analog part. The work on the digital part of the B-scanner is reported in part (II) seperately.

  • PDF

분활된 색공간에서 비선형 다중회귀 분석법을 이용한 스캐너 캘리브레이션에 관한 연구 (A study on scanner calibration method using nonlinear regression analysis in sub-divided color space)

  • 김나나;구철희
    • 한국인쇄학회지
    • /
    • 제19권1호
    • /
    • pp.4-16
    • /
    • 2001
  • Most important step for the color matching in scanner is the color coordinate transformation from the scanner RGB space to device independent uniform color space. A variety of color calibration technologies have been developed for input device. Linear or nonlinear matrices have been conveniently applied to correct the color filter's mismatch with color matching function in scanners. The color matching accuracy is expected to be further improved when the nonlinear matrices are optimized into subdivided smaller color spaces than in single matrix of the entire color space. This article proposed the scanner calibration method using subspace division regression analysis and it were compared with conventional method.

  • PDF

나노계면 형성을 위한 초음파 진동자 위치보정을 위한 레이저 스캐닝 기술 (Laser Scanning Technology for Ultrasonic Horn Location Compensation to Modify Nano-size Grain)

  • 김경한;이제훈;김현세;박종권;윤광호
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1121-1126
    • /
    • 2014
  • To compensate location error of ultrasonic horn, the laser scanning system based on the galvanometer scanner is developed. It consists of the 3-Axis linear stage and the 2-Axis galvanometer scanner. To measure surface shape of three-dimensional free form surface, the dynamic focusing unit is adopted, which can maintain consistent focal plane. With combining the linear stage and the galvanometer scanner, the scanning area is enlarged. The scanning CAD system is developed by stage motion teaching and NURBS method. The laser scanning system is tested by marking experiment with the semi-cylindrical sample. Scanning accuracy is investigated by measured laser marked line width with various scanning speed.

확장 칼만 필터를 이용한 대상 상태 추정 기반 자율주행 대차의 모델 예측 추종 제어 알고리즘 (A Model Predictive Tracking Control Algorithm of Autonomous Truck Based on Object State Estimation Using Extended Kalman Filter)

  • 송태준;이혜원;오광석
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.22-29
    • /
    • 2019
  • This study presented a model predictive tracking control algorithm of autonomous truck based on object state estimation using extended Kalman filter. To design the model, the 1-layer laser scanner was used to estimate position and velocity of the object using extended Kalman filter. Based on these estimations, the desired linear path for object tracking was computed. The lateral and yaw angle errors were computed using the computed linear path and relative positions of the truck. The computed errors were used in the model predictive control algorithm to compute the optimal steering angle for object tracking. The performance evaluation was conducted on Matlab/Simulink environments using planar truck model and actual point data obtained from laser scanner. The evaluation results showed that the tracking control algorithm developed in this study can track the object reasonably based on the model predictive control algorithm based on the estimated states.

Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

  • Yun, Dalsun;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen
    • 대한치과교정학회지
    • /
    • 제48권4호
    • /
    • pp.262-267
    • /
    • 2018
  • The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구 (Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner)

  • 김재홍;이정수;심정석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

The Evaluations of Sensor Models for Push-broom Satellite Sensor

  • Lee, Suk-Kun;Chang, Hoon
    • Korean Journal of Geomatics
    • /
    • 제4권1호
    • /
    • pp.31-37
    • /
    • 2004
  • The aim of this research is comparing the existing approximation models (e.g. Affine Transformation and Direct Linear Transformation) with Rational Function Model as a substitute of rigorous sensor model of linear array scanner, especially push-broom sensor. To do so, this research investigates the mathematical model of each approximation method. This is followed by the assessments of accuracy of transformation from object space to image space by using simulated data generated by collinearity equations which incorporate or depict the physical aspects of linear array sensor.

  • PDF