• Title/Summary/Keyword: Linear Kelvin - Helmholtz Instability Theory

Search Result 4, Processing Time 0.018 seconds

Prediction of drop size by analysis of conical liquid sheet breakup (원추형 액막분열 해석에 의한 액적 크기 예측)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.2 no.1
    • /
    • pp.8-17
    • /
    • 1997
  • A study has been carried out on the instability of a conical liquid sheet by using the linear instability theory. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed the the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. The predicted drop size agreed well with the measured Sauter mean diameter, $D_{32}$.

  • PDF

A Study on the Prediction of the Drop Size Distribution of Pressure-Swirl Atomizer (압력식 스월 노즐의 액적 크기분포 예측에 관한 연구)

  • Cho, D.J.;Yoon, S.J.;Kim, D.W.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1996
  • A theoretical and experimental study was carried out on the prediction of drop size distribution of the pressure swirl atomizer. Drop size distribution was obtained by using maximum entropy formal ism. Several constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of the estimating source terms. In this study $D_{10}$ was only introduced into the formulation as a constraint. A drop size obtained by using linear Kelvin-Helmholtz instability theory was considered as an unknown characteristic length scale. As a result, the calculated drop size was agreed well with measured mean diameter, particularly with $D_{32}$. The predicted drop size distribution was agreed welt with experimental data measured wi th Malvern 2600.

  • PDF

A numerical analysis and experimental study on the prediction of spray characteristics (분무특성 예측을 위한 이론적 접근과 실험적 연구)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.1-13
    • /
    • 1998
  • A theoretical and experimental study was carried out to predict the drop size distribution of the pressure swirl atomizer. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed that the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. Drop size distribution was obtained by using maximum entropy formalism. Seven constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of estimating source terms. In this study $D_{10}$ only was introduced into the formulation as a constraint. The predicted drop size and drop size distribution agreed well with the measured data.

  • PDF

Spray modelization of air-assisted coaxial atomizer (이류체 분사노즐의 분무예측 모델)

  • Yun, Seok-Ju;Ledoux, M.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.1948-1958
    • /
    • 1996
  • Experimental and theoretical studies on the air-assist coaxial atomizer have been continuously carried out for a long time. But now the importance of the theoretical study is tending to increase as with the development of computer. This study is concerned to the spray modelization, especially, the instability of the liquid jet surrounded by the air stream which flows with high velocity. To study the phenomena of the break up, we used the linear theory based on the classical Kelvin-Helmholtz theory for capillary wave at a simple interface and we investigated the variation of liquid core radius. As a result, we obtained that the drop diameter and the variation of the liquid core radius predicted by using our model are reasonable.