• Title/Summary/Keyword: Line-spring 유한요소

Search Result 19, Processing Time 0.023 seconds

Performance Evaluation and Sensitivity Analysis of the Pantograph for the High-Speed Train Using Finite Element Analysis Method (유한요소해석 기법을 이용한 고속철도용 판토그래프 집전성능 평가 및 민감도 분석)

  • Lee, Jin-Hee;Paik, Jin-Sung;Kim, Young-Guk;Park, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1874-1880
    • /
    • 2011
  • In this paper, sensitivity analysis of the pantograph for the high-speed Train was conducted using finite element analysis method. Dynamic interaction of catenary-pantograph model was simulated by using a commercial finite element analysis software, SAMCEF. Pantograph was assumed to be three degree of freedom mass-spring-damper model and the pre-sag of the contact and messenger wire was implemented due to gravity. The span data of the actual high-speed line and specification of pantograph for high-speed train was applied in the analysis model, respectively. The reliability of the simulation model is verified by comparing the contact force results of simulation and test. Through the simulation, mean contact force and its deviation was evaluated and then sensitivity of the pantograph was analyzed.

  • PDF

Defect Assessment for Integrity Evaluation of CANDU Pressure Tubes (CANDU 압력관 건전성평가를 위한 결함해석)

  • 김영진;석창성;박윤원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.731-740
    • /
    • 1995
  • The objective of this paper is to develop defect assessment technology for integrity evaluation of CANDU pressure tubes. In fracture mechanics analysis, three-dimensional and two-dimensional (line-spring model) finite element analyses were performed to obtain the stress intensity factor for axial and circumferential surface cracks. In leak before break (LBB) analysis, heat transfer analyses for through-wall cracks were performed by considering the cooling effect and the LBB application time was computed. It was shown that the analytical results obtained in this study provide less-conservative but accurate solution for defect assessment of CANDU pressure tubes.

Wave Control Performance of Moored Pontoon-Type Floating Breakwater (계류된 사각형 부유식 방파제의 파랑제어성능)

  • Cho I. H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.3
    • /
    • pp.35-44
    • /
    • 2002
  • In this paper, the analytic studies on the wave control performance of moored pontoon-type floating breakwater are presented. A two-dimensional eigenfunction expansion method is adopted to study the motion responses and the transmission coefficients of pontoon-type floating breakwater in beam waves. The stiffness coefficients of mooring line are idealized as linear elastic spring. Comparison of the analytical results with a numerical results (FEM) shows good agreement over a wide range of frequencies. The performance of mooed pontoon-type floating breakwater is tested with various design parameters such as sectional geometry, mooring line characteristics and wave frequencies. It is found that the properly designed floating breakwater can be an effective wave control structure.

  • PDF

Study on Damping Coefficient of Shock Absorber with Magnetic Effects (자기효과를 이용한 충격흡수장치의 감쇠계수에 관한 연구)

  • Yi, Mi-Seon;Bae, Jae-Sung;Hwang, Jae-Hyuk;Hwang, Do-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.9
    • /
    • pp.832-838
    • /
    • 2011
  • The shock absorber with magnetic effect is suggested for a lunar lander. The shock absorber consists of a metal tube, a piston rod, and several permanent magnets moved by a piston rod in the tube, and the shock energy can be dispersed and dissipated by magnetic effects such as the magnetic force existed between a metal and magnets and the eddy current effect generated by a relative motion with a conductor and magnets. Besides, the shock-absorbing effect similar to that of a coil spring can be obtained by arranging the magnets in line, which are facing the same polar each other. The device has a very simple structure and is usable in space due to the unnecessariness of any oil or gas. The shock absorber was designed and manufactured for experiments and its spring and damping characteristics were studied by the theoretical, analytical and experimental methods.

Prediction of Influence of Polluted Water Discharged from Saemankeum Lake (새만금 간척지구 담수호 건설에 따른 담수배출의 영향범위 예측)

  • Kim, Dae-Geun;Seo, Il-Won;Baek, Gyeong-O
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.649-659
    • /
    • 1997
  • The influence of polluted water discharged from the Saemankeum Lake is predicted by using two-dimensional finite element model. The simulation results show that influence of the Polluted water to the northern part of the Kckunsan Islands is small during flood time. The reason is because lock gates are located in the south of the Kokunsan Islands so that tidal current directing north is blocked by these Islands. However, during the ebb time, the influence of the polluted water is extended to the whole southern part of the Kokunsan Islands. When the amount of ten percent of the total volume of polluted water is discharged from the Saemankeum Lake, equi-concentration contour line of one tenth of initial discharge concentration includes the inner area surrounded by Sinsi Island, Munyeo Island, Bian Island, and Daehang-Li. In general, peak concentration near the lock gates is found out to be higher during the spring tide than the neap tide.

  • PDF

Prediction of Residual Deformation and Stress Distribution for a Thermo-Elastic-Plastic Beam Using a Simplified Numerical Analysis (간이 수치해석에 의한 열탄소성보의 잔류변형 및 응력분포의 예측)

  • S.H. Jun;K. Choi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.3
    • /
    • pp.22-34
    • /
    • 1996
  • Regarding the plate bending process by line heating method, in this study a simplified numerical analysis is performed for a beam model to predict its residual deformation and stress distribution. Using the modified strip theory and beam finite element method, a PC-based simulation program is developed for a thermo-elastic-plastic beam. The plate bending problem can be approximately replaced by a beam model using distributed springs to account for the effect of adjacent strips. The spring constants are chosen as the best fit with experiments. In this paper, it is assumed that the temperature distribution is already given and the temperature-dependent material properties are considered. To verify the simulation program, the results using present numerical algorithm are compared with other published experimental results and similar numerical studies. The comparison shows good agreement. The present PC-based computer program also shows good efficiency in computing time.

  • PDF

The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide (레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발)

  • Lee, Sang-Won;Kim, Wi-Han;Jung, Young-Dae;Park, Min-Kyu;Kim, Jee-Hyun;Lee, Sang-In;Lee, Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • A confocal microscope was developed utilizing a scanning sample stage based on a home-built double-compound flexure guide. A scanning sample stage with nano-scale resolution consisted of a double leaf spring based flexure, a displacement amplifying lever, a Piezo-electric Transducer(PZT) actuator and capacitance sensors. The performance of the two-axis stage was analyzed using a commercial finite element method program prior to the implementation. A single line laser was employed as the light source along with the Photo Multiplier Tube(PMT) that served as the detector. The performance of the developed confocal microscope was evaluated with a mouse ear skin imaging test. The designed scanning stage enabled us to build the confocal microscope without the two optical scanning mirror modules that are essential in the conventional laser scanning confocal microscope. The elimination of the scanning mirror modules makes the optical design of the confocal microscope simpler and more compact than the conventional system.

Damage Evaluation of Track Components for Sleeper Floating Track System in Urban Transit (도시철도 침목플로팅궤도 궤도구성품의 손상평가)

  • Choi, Jung-Youl;Kim, Hak-Seon;Han, Kyung-Sung;Jang, Cheol-Ju;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.387-394
    • /
    • 2019
  • In this study, in order to evaluate the damage and deterioration of the track components of sleeper floating track (STEDEF), the field samples(specimens) were taken from the serviced line over 20 years old, and the track components were visually inspected, and investigated by laboratory tests and finite element analysis. As a result of visual inspection, the damage of the rail pad and fastener was slight, but the rubber boot was worn and torn at the edges of bottom. The resilience pads were clearly examined for thickness reduction and fatigue hardening layer. As a result of spring stiffness test of rail pad and resilience pad, the deterioration of rail pad was insignificant, but the deterioration of resilience pad exceeded design standard value. Therefore resilience pad was directly affected by train passing tonnage. As a result of comparing the deterioration state of the field sample and the numerical analysis result, the stress and displacement concentration position of the finite element model and the damage position of the field sample were coincident.

Stability Analysis of Concrete Plugs Installed in Pilot Tunnels for the Storage of Compressed Air (압축공기 저장용 파일롯 터널에 설치된 콘크리트 플러그의 안정성 해석)

  • Lee, Youn-Kyou;Song, Won-Kyoung;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.446-454
    • /
    • 2010
  • CAES-G/T (Compressed Air Energy Storage - Gas Turbine) power generation is a likely option for the buffer facility stabilizing the fluctuation of the renewable powers, such as wind and solar powers. Considering the geological conditions, the underground CAES facility is most probable if the CAES-G/T generation is planed in Korea. In this kind of facility, a concrete plug is installed to seal the compressed air in the container, so that the selection of the shape and dimension of concrete plug could be a critical design factor. The stability evaluation of two types of plug was carried out by investigating the distribution of the factor of safety in the plugs and the distribution of contact pressure over the contact surface. The analysis result shows that the taper-shaped plug is more structurally stable than the wedge-shaped plug for the given geological condition. Possible separation of the rock-concrete interface around the spring line of the wedge-shaped plug is anticipated, which means the possible leakage of compressed air through the side wall and also means the poor mobilization of frictional resistance on that area.