• Title/Summary/Keyword: Line-grid method

Search Result 249, Processing Time 0.031 seconds

Power Integrity and Shielding Effectiveness Modeling of Grid Structured Interconnects on PCBs

  • Kwak, Sang-Keun;Jo, Young-Sic;Jo, Jeong-Min;Kim, So-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.320-330
    • /
    • 2012
  • In this paper, we investigate the power integrity of grid structures for power and ground distribution on printed circuit board (PCB). We propose the 2D transmission line method (TLM)-based model for efficient frequency-dependent impedance characterization and PCB-package-integrated circuit (IC) co-simulation. The model includes an equivalent circuit model of fringing capacitance and probing ports. The accuracy of the proposed grid model is verified with test structure measurements and 3D electromagnetic (EM) simulations. If the grid structures replace the plane structures in PCBs, they should provide effective shielding of the electromagnetic interference in mobile systems. An analytical model to predict the shielding effectiveness (SE) of the grid structures is proposed and verified with EM simulations.

A study on Grid deck for LRT (경량전철용 I형강 격자바닥판에 관한 연구)

  • 이기승;백진기;구자성;이안호;성택룡
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.328-335
    • /
    • 2000
  • The substructure of Light Rail Transit is mainly built on elevated structure that is composed of pier, girder and bridge deck. The bridge deck mostly has been made by field formed reinforced concrete so far. The objectives of the study are to find a method for design and construction of the new bridge deck. I-beam is fabricated to make grid and concrete is poured on it at factory. This type can be used for maintenance of duty line by advantages such as good quality control and short construction time.

  • PDF

Application of MMC-HVDC System for Regulating Grid Voltage Based on Jeju Island Power System (제주계통의 전압조정을 위한 MMC-HVDC 시스템 응용)

  • Quach, Ngoc-Thinh;Kim, Eel-Hwan;Lee, Do-Heon;Kim, Ho-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.494-502
    • /
    • 2014
  • This paper presents a control method of the modular multilevel converter - high-voltage direct current (MMC-HVDC) system to regulate grid voltage on the basis of the Jeju Island power system. In this case, the MMC-HVDC system is controlled as a static synchronous compensator (Statcom) to exchange the reactive power with the power grid. The operation of the MMC-HVDC system is verified by using the PSCAD/EMTDC simulation program. The Jeju Island power system is first established on the basis of the parameters and measured data from the real Jeju Island power system. This power system consists of two line-commutated converter - high-voltage direct current (LCC-HVDC) systems, two Statcom systems, wind farms, thermal power plants, transformers, and transmission and distribution lines. The proposed control method is then applied by replacing one LCC-HVDC system with a MMC-HVDC system. Simulation results with and without using the MMC-HVDC system are compared to evaluate the effectiveness of the control method.

Improvement of Pedestrian Convenience and Mobility by Applying the Walking Guidance System in Subway Stations (지하철 역사내 동선 분리 시스템을 활용한 보행편의 및 이동성 증진)

  • Lee, Joo-Yong;Kim, Taewan;You, So-Young
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.2
    • /
    • pp.204-213
    • /
    • 2015
  • The congestion of pedestrians impedes the utilization efficiency of a subway station. Conflicts among pedestrians due to unseparated pedestrian flows not only increase the impedance of pedestrian mobility but also negatively affect on pedestrian safety. This paper analyzes the travel characteristics of bi-directional pedestrian flow based on microscopic movements, and evaluates the operation efficiency on separating the traffic line. The subway station was simulated in a 2-D grid structure by applying Discrete Element Method, and the movement is organized in each cell of the grid. As a result, the model explicates that separating the traffic line and encouraging the 'Keep right rule' would be mostly effective for the conflicting flows. Therefore, applying the 'Walking Guidance System' would be efficient to improve the pedestrian convenience and mobility.

A Comparative Study on Spatial and Temporal Line Interpolation of Characteristic Method (공간 및 시간준위 보간 특성곡선법의 비교연구)

  • 백중철;배덕효
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.203-212
    • /
    • 1996
  • The subject research attempts to develop a new temporal interpolation scheme for the method of characteristics. The proposed three-point time-line Lagrange interpolation Reachback (3PR) method is a temporal quadratic interpolation scheme using the three grid points near the intersection between a characteristic line and a previous time-line. The accuracy of the 3PR method is compared with those of temporal and spatial interpolation schemes such as Reachback, Upwind, and quandratic spatial interpolation methods for two pure advection problems. The results show that on the aspects of the numerical damping and/or oscillation the temporal interpolation schemes are better than the spatial ones under the same interpolation order conditions. In addition, the spatial ones under the same interpolation order conditions. In addition, the proposed 3PR method improves the accuracy of Reachback method as well as it contains the merits of time-line interpolation schemes.

  • PDF

A Study on the Camera Calibration Algorithm using Perspective Ratio of Difference Line Widths

  • Jeong, Jun-Ik;Song, Suck-Woo;Lee, Ho-Soon;Rho, Do-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.1-63
    • /
    • 2001
  • At 3-D vision measuring, the camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. One is that establishes reference points in space, and the other is that uses the grid type frame and statistical method. But, the former has difficult to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. The advantage of this algorithm is that it can estimate position, pose and distance between camera and object ...

  • PDF

A New On-Line Dead-Time Compensator for Single-Phase PV Inverter (단상 PV 인버터용 온-라인 데드타임 보상기 연구)

  • Vu, Trung-Kien;Cha, Han-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.216-217
    • /
    • 2010
  • This paper presents a new software-based on-line dead-time compensation technique for single-phase grid-connected photovoltaic (PV) inverter system. To improve the mitigation of dead-time effect around the zero-crossing point of phase current, a selective harmonic elimination of instantaneous feedback current is used as an additional part of conventional current control scheme. Simulation and experimental results are shown to verify the effectiveness of proposed compensation method in the grid-connected power distributed generation systems.

  • PDF

A PDR model for UV heated outflow walls around protostars

  • Lee, Seok-Ho;Lee, Jeong-Eun;Park, Young-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.114.2-114.2
    • /
    • 2011
  • We have developed a PDR code to reproduce the high rotational transitions of CO observed with Herschel-PACS. Part of these high-J CO line emission is produced by UV heated outflow walls around protostars. The local FUV radiation flux is calculated by using Monte Carlo method in (${\gamma}$, ${\alpha}$) grid taking anisotropic scattering into account. Kinetic temperature and Abundance of molecules were computed self-consistently. CO Line fluxes are calculated using RIG. We compare our PDR model with the results by Visser et al (2011) to show that the derived FUV radiation field strength can be affected by the grid resolution near the outflow wall and dust scattering.

  • PDF

Internal Generation of Nonlinear Waves for Extended Boussinesq Equations: Line Source Method and Source Function Method (확장형 Boussinesq 방정식에서 비선형파의 내부 조파: 선 조파기법과 원천함수기법)

  • Kim Gunwoo;Lee Changhoon;Suh Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.1
    • /
    • pp.21-31
    • /
    • 2005
  • In this study, derivation is made of a one-grid source function for the extended Boussinesq equations of Nwogu (1993) in order to generate nonlinear waves internally. The energy velocity approach used in the line source method is verified analytically by the fractional step splitting method. The source function method is verified by generating accurately nonlinear waves as well as linear waves for horizontally one-dimensional cases. It is found that numerical solutions by the source function method are the same as those by the line source method.

Single Phase Grid Connected Voltage-ed Inverter Utilizing a Power Decoupling Function (전력 디커플링 기능을 가진 단상 계통연계 전압형 인버터)

  • Lee, Sang-Wook;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.236-241
    • /
    • 2017
  • This paper presents a single-phase grid connected voltage-ed inverter with a power decoupling circuit. In the single-phase grid connected voltage-ed inverter, it is well known that a power pulsation with twice the grid frequency is contained in the input power. In a conventional voltage type inverter, electrolytic capacitors with large capacitance have been used in order to smooth the DC voltage. However, lifetime of those capacitors is shortened by the power pulsation with twice grid frequency. The authors have been studied a active power decoupling(APD) method that reduce the pulsating power on the input DC bus line, this enables to transfer the ripple energy appeared on the input DC capacitors into the energy in a small film capacitor on the additional circuit. Hence, extension of the lifetime of the inverter can be expected because the small film capacitor substitutes for the large electrolytic capacitors. Finally, simulation and experimental results are discussed.