• 제목/요약/키워드: Line-by-Line Model

검색결과 3,759건 처리시간 0.032초

Estimation of Relative Potency with the Parallel-Line Model

  • Lee, Tae-Won
    • 응용통계연구
    • /
    • 제25권4호
    • /
    • pp.633-640
    • /
    • 2012
  • Biological methods are described for the assay of certain substances and preparations whose potency cannot be adequately assured by chemical or physical analysis. The principle applied through these assays is of a comparison with a standard preparation to determine how much of the examined substance produces the same biological effects as a given quantity (the Unit) of the standard preparation. In these dilution assays, to estimate the relative potencies of the unknown preparations to the standard preparations, it is necessary to compare dose-response relationships of standard and unknown preparations. The dose-response relationship in the dilution assay is non-linear and sigmoid when a wide range of doses is applied. The parallel line model (applied to the dose region with the steepest slope) is used to estimate the relative potency. In this paper, the statistical theory in the parallel line model is explained with an application to a dilution assay data. The parallel line method is implemented in a SAS program and is available at the author's homepage(http://cafe.daum.net/go.analysis).

시뮬레이션을 이용한 백라이트유닛의 생산공정예측 (A Simulation on The BLU Assembly Line)

  • 김승남;문제창;임석철
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2005년도 춘계공동학술대회 발표논문
    • /
    • pp.1047-1051
    • /
    • 2005
  • Many corporation invest in LCD industry because of The growth of it. Back Light Unit(BLU), LCDs' main part take 20% of its product costs. In this paper we proposed simulation model that is in the process of introducing an equipment, We try to apply a simulation model in the BLU Assembly line by using ARENA. We make BLU Assembly line with various part storage, product strorage. etc. We evaluate Logistics in Assembly Line, and forecast bottleneck and throughput

  • PDF

Hairpin Line 여파기의 간단화된 등가회로 (Simplified Equivalent Circuit of Hairpin Line Filters)

  • 곽우영;박진우
    • 한국통신학회논문지
    • /
    • 제24권9A호
    • /
    • pp.1434-1441
    • /
    • 1999
  • 본 논문에서는 Hairpin Line 여파기의 정확한 해석 및 설계를 위한 등가회로를 제시하였으며 제시된 등가회로의 유효성을 컴퓨터 시뮬레이션과 설계를 통해 입증하였다. Hairpin Line 여파기에 대한 설계식은 다양하게 제시되었으나, 인접하지 않는 소자간의 상호 연결성을 포함한 실제적으로 간단화된 등가회로는 아직 명시되고 있지 못하다. 본 논문에서는 회로 duality을 이용하여 Hairpin Line 여파기 회로의 모든 개방단자를 단락단자로 변환하고, 변환된 회로를 그래프 모델로 표시하였다. 또한 각 단자에서의 경계조건으로부터 보다 간략화된 회로모델을 구하고 역 dual구조로 변환하여 Hairpin Line 여파기에 대한 간단화된 등가회로를 유도하였다.

  • PDF

Dynamic response of an overhead transmission tower-line system to high-speed train-induced wind

  • Zhang, Meng;Liu, Ying;Liu, Hao;Zhao, Guifeng
    • Wind and Structures
    • /
    • 제34권4호
    • /
    • pp.335-353
    • /
    • 2022
  • The current work numerically investigates the transient force and dynamic response of an overhead transmission tower-line structure caused by the passage of a high-speed train (HST). Taking the CRH2C HST and an overhead transmission tower-line structure as the research objects, both an HST-transmission line fluid numerical model and a transmission tower-line structure finite element model are established and validated through comparison with experimental and theoretical data. The transient force and typical dynamic response of the overhead transmission tower-line structure due to HST-induced wind are analyzed. The results show that when the train passes through the overhead transmission tower-line structure, the extreme force on the transmission line is related to the train speed with a significant quadratic function relationship. Once the relative distance from the track is more than 15 m, the train-induced force is small enough to be ignored. The extreme value of the mid-span dynamic response of the transmission line is related to the train speed and span length with a significant linear functional relationship.

전차선로 시스템의 5 도체 등가 축약 모델링 (A Reduced Equivalent 5 conductors Modeling of the Catenary System)

  • 이한민;오광해;이장무;창상훈;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.684-690
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model, then the line constants of this equivalent five-conductors model are calculated. This paper shows the reducing process about the real system of the field by using the proposed theory. Also the line constants of reduced system are provided in this paper.

마이크로파 feed line을 고려한 진행파형 광 변조기의 특성 분석 (Microwave characteristics of traveling-wave modulator considering the microwave feed-line)

  • 구민주;옥성해;최영완
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2003년도 하계학술대회
    • /
    • pp.172-174
    • /
    • 2003
  • In this paper, we analyze the traveling-wave electro-absorption modulator (TW-EAM) in consideration of the microwave feed-line. The TW-EAM is analyzed by using the equivalent circuit model. The microwave feed-line isanalyzed by momentum method. In a view point of microwave characteristics, we present the effect of the structure and the length of microwave feed-line.

  • PDF

지구 대기 흡수선 스펙트럼 계산 (CALCULATION OF TELLURIC ABSORPTION SPECTRA)

  • 정광희;한인우;이병철
    • 천문학논총
    • /
    • 제29권3호
    • /
    • pp.35-44
    • /
    • 2014
  • In ground-based astronomical spectroscopic observations, there are many telluric absorption lines that are laid on the spectra of celestial objects. To study the physical properties of the celestial objects with these contaminated spectra, the telluric lines should be removed. A conventional method for removing the telluric lines is using the standard stellar spectrum as telluric line. In this paper, we introduce a technique to calculate synthetic telluric spectra and use them to remove telluric lines from a spectrum of a celestial object. We used Line-by-Line Radiative Transfer Model (LBLRTM) for calculating a synthetic spectrum and selected Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) model as atmospheric model. We apply our method to some spectra obtained by Bohyunsan Observatory Echelle Spectrograph (BOES) to show that the telluric lines are well removed from the observed spectra by our model within an accuracy of 2% which is close to the 1-sigma rms of the original spectra.

송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구 (A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay)

  • 서훈철;이홍학;김철환;이재욱;장병태;곽노홍;김호표;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF

송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용 (Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units)

  • 조기선;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

튜브 벤딩시 스프링백 보정각 추세선 도출에 관한 연구 (A Study on the Derivation of Springback Compensation Angle Trend Line in Tube Bending)

  • 이덕영;오성국;최보성
    • 소성∙가공
    • /
    • 제29권4호
    • /
    • pp.188-193
    • /
    • 2020
  • Piping work of large ships or offshore plants is often done in a narrow and confined space, requiring precise bending and safety. In order to realize an accurate bending angle, it is very important to predict and correct a deformation that may be caused by elasticity in the bending process, that is, an angular deviation due to springback. Therefore, by using CAE analysis to develop a correction angle model for springback based on multiple tube bending angles and using trend line data derived from this correction angle model, at bending the tube as the diameter of the base former and the tube outer diameter change, the springback compensation angle at any angle can be obtained. In this study, the bending mechanism was analyzed to increase the bending precision, and a correction angle model was developed and a trend line was derived in consideration of springback occurring in the bending process. In order to derive a more accurate and reliable trend line, a tube tensile test was performed, and the reliability of the corrected angle trend line was verified by comparing the bending angle measurement and analysis results with a 3D scanner.