• Title/Summary/Keyword: Line source method

Search Result 514, Processing Time 0.028 seconds

A Field-based Morphing with Semi-automatic Control Lines Matching Using Image Segmentation (영상 분할을 이용한 반자동 제어선 정합에 의한 필드 기반 모핑)

  • Lee Hyoung-Jin;Kwak No-Yoon
    • Journal of Digital Contents Society
    • /
    • v.5 no.4
    • /
    • pp.269-274
    • /
    • 2004
  • The field based morping requires the user to set most of the control lines manually which require much time and skill to get satisfactory results. This tjesis proposes a method to acquire semi-automation of image morphing through first acquiring shape information from the source image and the target image, than after the user manually designates the least amount of a pair of feature points, these are used as standards for polygon based vertex to set the appropriate control line to the source image and target image, and then using the ratio of control line lengths and space. Using the proposed method the user can reduce the time setting the control line and unskilled persons can get natural image morphing results while desingnating the least amount of control line.

  • PDF

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.

Loose Coupling Approach of CFD with a Free-Wake Panel Method for Rotorcraft Applications

  • Lee, Jae-Won;Oh, Se-Jong;Yee, Kwan-Jung;Kim, Sang-Hun;Lee, Dong-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • As a first step toward a complete CFD-CSD coupling for helicopter rotor load analysis, the present study attempts to loosely couple a CFD code with a source-double panel method. The far-field wake effects were calculated by a time-marching free vortex wake method and were implemented into the CFD module via field velocity approach. Unlike the lifting line method, the air loads correction process is not trivial for the source-doublet panel method. The air loads correction process between the source-doublet method and CFD is newly suggested in this work and the computation results are validated against available data for well-known hovering flight conditions.

On-line PD Monitoring Using UHF Technique (UHF 가술을 이용한 온라인 PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Thermal measurement of Geomaterials using Transient Plane Source (비정상면열원법을 이용한 지반물질의 열전달 특성 평가)

  • Kim, Young-Jin;Yun, T.S.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.45-52
    • /
    • 2010
  • Thermal properties of geomaterial are overlooked with other geomechanical properties. The transient line-source (TLS) method is one of the most used testing methods for measuring the thermal conductivity (K) and thermal diffusivity ($\alpha$) of materials. But more recently, Transient Plane-Source method was developed to measure these. It has several advantage of comparing with TSL method, but there has not been documented application in geomaterial. A Resistance Temperature Detector is used to construct sensor. For durability of Probe, Adopt a new technique that two probes are bonded in exact matching. For standard materials, such as glycerin, and ice the measured K and a values of these materials were generally within 2-5% from the standard values in the literature. This document present to evaluate the thermal properties of geomaterials and its application was tested for varying degree of saturation using the Transient Plane Source method. The result of this study suggests that it is an comparatively accurate method for simultaneously measuring thermal conductivity and thermal diffusivity and can identify the feasibility to geomaterial.

  • PDF

Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source (미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용)

  • Ahn, Woo-Sang;Jang, Won-Woo;Park, Sung-Ho;Jung, Sang-Hoon;Cho, Woon-Kap;Kim, Young-Seok;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.190-197
    • /
    • 2011
  • Currently, the dose distribution calculation used by commercial treatment planning systems (TPSs) for high-dose rate (HDR) brachytherapy is derived from point and line source approximation method recommended by AAPM Task Group 43 (TG-43). However, the study of Monte Carlo (MC) simulation is required in order to assess the accuracy of dose calculation around three-dimensional Ir-192 source. In this study, geometry factor was calculated using segmented sources integration method by dividing microSelectron HDR Ir-192 source into smaller parts. The Monte Carlo code (MCNPX 2.5.0) was used to calculate the dose rate $\dot{D}(r,\theta)$ at a point ($r,\theta$) away from a HDR Ir-192 source in spherical water phantom with 30 cm diameter. Finally, anisotropy function and radial dose function were calculated from obtained results. The obtained geometry factor was compared with that calculated from line source approximation. Similarly, obtained anisotropy function and radial dose function were compared with those derived from MCPT results by Williamson. The geometry factor calculated from segmented sources integration method and line source approximation was within 0.2% for $r{\geq}0.5$ cm and 1.33% for r=0.1 cm, respectively. The relative-root mean square error (R-RMSE) of anisotropy function obtained by this study and Williamson was 2.33% for r=0.25 cm and within 1% for r>0.5 cm, respectively. The R-RMSE of radial dose function was 0.46% at radial distance from 0.1 to 14.0 cm. The geometry factor acquired from segmented sources integration method and line source approximation was in good agreement for $r{\geq}0.1$ cm. However, application of segmented sources integration method seems to be valid, since this method using three-dimensional Ir-192 source provides more realistic geometry factor. The anisotropy function and radial dose function estimated from MCNPX in this study and MCPT by Williamson are in good agreement within uncertainty of Monte Carlo codes except at radial distance of r=0.25 cm. It is expected that Monte Carlo code used in this study could be applied to other sources utilized for brachytherapy.

Extended Fault Location Algorithm Using the Estimated Remote Source Impedance for Parallel Transmission Lines

  • Ryu, Jeong-Hun;Kang, Sang-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2212-2219
    • /
    • 2018
  • This paper describes extended fault location algorithm using estimated remote source impedance. The method uses data only at the local end and the sequence current distribution factors for more accurate estimation. The proposed algorithm can respond to variation of the local and remote source impedance. Therefore, this method is especially useful for transmission lines interconnected to a wind farm that the source impedance varies continuously. The proposed algorithm is very insensitive to the variation in fault distance and fault resistance. The simulation results have shown the accuracy and effectiveness of the proposed algorithm.

Switching Power Module for a Small-Sized Electric Power Source (소형 전원용 스위칭 파워 모듈)

  • 김병철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.1068-1073
    • /
    • 2004
  • 5 V/500 mA transless type power module was designed by using a semiconductor switching technique for a small-sized electric power source. It used voltage drop type chopper method, and is composed of switching circuit, control circuit, voltage detect circuit, and constant voltage circuit. The switching power module which is designed in this study, showed load regulation of 0.2 V, line regulation of 0.1 V, output ripple of 85 mVp-p, switching frequency of 64.7 kHz, maximum power efficiency of 58 %, and satisfied its reliability and EMC test.

The Identification of Vibration Source and Its Transmission Paths In Compressor Using PCF Method (PCF법을 이용한 왕복동압축기의 진동원 및 진동전달경로 규명)

  • Lee, Dae-Sung;Hwang, Won-Gul;Lee, You-Yub;Im, Hyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.386.1-386
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor Through the use of multiple-input/single-output(MISO) model, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. (omitted)

  • PDF

Consideration of Roman Character in KS × 1001 Code System for Information Interchange considered AMI/HDB-3 and HDLC FLAG (AMI/HDB-3 회선부호화 및 HDLC FLAG를 고려한 KS × 1001 정보 교환용 로마문자 부호체계고찰)

  • Hong, Wan-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.1017-1023
    • /
    • 2013
  • Datacommunications transmit the source codes that are coded in information devices, such as computer to the transmission line by means of the line coded signal. AMI method is applied to the line coding method to transmit the signal for long distance. The disadvantage of the AMI method is to loss the bit synchronization when consecutive binary bit '0' over 4ea is coming into line coder. The scrambling technique is used to overcome the problem. The HDB-3 scrambling method is used in Korea standard which standard in ITU-T. When the HDB-3 technology is used. the method should convert the consecutive bit '0' over 4ea to certain bits format. As a result, when there are many such kind of '0' bit stream in source codes, data transmission efficiency will be decreased to treat in line coder, etc. This paper is directed to study the Roman character code system in $KS{\times}1001$, Korea standard for information exchange code in datacommunication systems. Based on the study result, this paper proposed the maximum optimized Roman character code system. In the study, Character coding rule for $4{\times}4$bits and the statistical data for roman character using frequency were considered to simulate. The paper shows the result that when the proposed new roman character coding system is applied to use, the data transmission efficiency could be increased to about 134% compared to existing code system.