• Title/Summary/Keyword: Line scanner

Search Result 141, Processing Time 0.029 seconds

Low-Complexity Handheld 3-D Scanner Using a Laser Pointer (단일 레이저 포인터를 이용한 저복잡도 휴대형 3D 스캐너)

  • Lee, Kyungme;Lee, Yeonkyung;Park, Doyoung;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.458-464
    • /
    • 2015
  • This paper proposes a portable 3-D scanning technique using a laser pointer. 3-D scanning is a process that acquires surface information from an 3-D object. There have been many studies on 3-D scanning. The methods of 3-D scanning are summarized into some methods based on multiple cameras, line lasers, and light pattern recognition. However, those methods has major disadvantages of their high cost and big size for portable appliances such as smartphones and digital cameras. In this paper, a 3-D scanning system using a low-cost and small-sized laser pointer are introduced to solve the problems. To do so, we propose a 3-D localization technique for a laser point. The proposed method consists of two main parts; one is a fast recognition of input images to obtain 2-D information of a point laser and the other is calibration based on the least-squares technique to calculate the 3-D information overall. To verified our method, we carry out experiments. It is proved that the proposed method provides 3-D surface information although the system is constructed by extremely low-cost parts such a chip laser pointer, compared to existing methods. Also, the method can be implemented in small-size; thus, it is enough to use in mobile devices such as smartphones.

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Development of the Broadband PLC Home Controller using JINI Surrogate

  • Kim, Yong-Seok;Kim, Hee-Sun;Lee, Chang-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1563-1567
    • /
    • 2005
  • The Home network system means that information appliances, Home PCs, etc., using wired or wireless network method enable to control and share with peripheral devices such as internet, shared data, a scanner and a printer, and it is networking solution, which intelligent communication will be possible as the system which can do a remote control such as TV Set, refrigerators, air conditioners, DVD players, digital camcorders based on external network using an internet, a potable information terminal and a mobile phone whenever, wherever and freely. In this study, the home network interface solution is used one of the wired network standards, PLC (Power-Line Communication) technology, so we can construct of intelligent home network's home controller without re-build a network at home. On keeping with current waves of thought, we will focus on a home controller development with great interest which is enabled to do an effective managed control, applying intelligent home network technology which can be new paradigm like a cyber apartment.

  • PDF

Pipelined Implementation of JPEG Baseline Encoder IP

  • Kim, Kyung-Hyun;Sonh, Seung-Il
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.29-33
    • /
    • 2008
  • This paper presents the proposal and hardware design of JPEG baseline encoder. The JPEG encoder system consists of line buffer, 2-D DCT, quantization, entropy encoding, and packer. A fully pipelined scheme for JPEG encoder is adopted to speed-up an image compression. The proposed architecture was described in VHDL and synthesized in Xilinx ISE 7.1i and simulated by modelsim 6.1i. The results showed that the performance of the designed JPEG baseline encoder is higher than that demanded by real-time applications for $1024{\times}768$ image size. The designed JPEG encoder IP can be easily integrated into various application systems, such as scanner, PC camera, color FAX, and network camera, etc.

Defects detection of TCP / COF using real-time line scanner (실시간 라인 스캐너를 이용한 TCP / COF의 불량 검출)

  • Kim, Yong-Sam;Moon, Hee-Jeong;Song, Chang-Kyu;Chun, Myung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.153-154
    • /
    • 2007
  • 본 논문에서는 반도체 패키징 기술의 일종인 TCP와 COF의 패턴 결함을 검출하는 영상 처리 알고리즘을 제안한다. 제안된 방법은 우선, TCP와 COF의 양품 패턴을 기준 영상으로 취득한다. 라인 스캐너에서 취득된 실시간 영상을 그레이로 변환한 후, 평균화 필터를 적용하고 임계값을 이용해서 검사하고자 하는 필름 영상의 이진화를 수행한다. 이진화 된 기준 영상과 검사하고자 하는 필름 영상을 이용해서 차영상을 구한 후에 라벨링을 하여 필름의 불량을 검출하게 된다. 제안된 패턴 매칭 방법이 TCP와 COF의 다양한 불량 항목 중에서 10여 가지의 불량 패턴을 대상으로 제안된 방법의 타당성을 검증하였다.

  • PDF

Use of Intraoral Scanners for Fabricating Fixed Restoration: Clinical Tips (구강 스캐너를 사용한 고정성 보철 수복 시 고려사항)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.524-528
    • /
    • 2019
  • With the advances of CAD-CAM (computer-aided design and computer-aided manufacturing) technology, the field of modern clinical dentistry has been dramatically changed. The first step in the digital workflow for tooth-supported dental prosthesis is a data acquisition with intraoral digital or conventional impression techniques. For the accuracy of intraoral digital impression data, the basic principles of conventional impression should be applied. It is necessary to obtain a good visibility with properly-dried field and well-exposed margin of the prepared abutment. Currently, the equi- or supra-gingival finish line can be recommended as an indication for intraoral digital impression. The scan data are generally exported to '.stl' file format, which has only morphological information of black and whitem while '.obj' file format can store data on color and texture.

  • PDF

A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER (3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구)

  • Lee, Jong-Beom;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.643-652
    • /
    • 2006
  • The purpose of this study was to elucidate the size and morphologic characteristics of maxillary primary first molars in Korean children using three-dimensional laser scanner and compare three-dimensional image with preformed stainless steel crown. Scanned three-dimensional images of dental cast taken from 132 children(male 62, female 70) by three-dimensional laser scanner(Breuckmann opto-Top HE100, INUS, Korea) were used. Mesiodistal diameter, buccolingual diameter, occlusogingival height and crown shape of each image were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared by independent samples t-test with 95% of significant level. The results were as follows : 1. No significant difference in crown size was found between left and right maxillay primary first molar(p>0.05). 2, Significant difference in mesiodistal diameter, buccolingual diameter, buccal occlusogingival height was found between male and female (p<0.05), and crown size of male was bigger than that of female. 3. Average image of maxillay primary first molar was shaped three-dimensionally and measured. In comparison with 3M stainless steel crown, this image was similar with No.4 or No.5 SS crown in male, No.4 in female. In comparison with ILSUNG SS crown, this image was similar with No.5 in male, No.4 in female. 4 Mesiolingual line angle area, distolingual line angle area and buccogingival ridge were more obvious in average image than 3M stainless steel crown. ILSUNG SS crown was more square and had longer mesiodistal diameter than average 3D image.

  • PDF

The Modified Hanbok Jeogori Pattern Development Using Virtual Dressing System - Based on Female Bodice Pattern -

  • Jeon, Seong Yeon;Wee, Hye Jung
    • Journal of Fashion Business
    • /
    • v.21 no.6
    • /
    • pp.66-76
    • /
    • 2017
  • This study used a virtual wearing system equipped with body shape data with a 3D scanner, based on a female basic bodice, to develop a modified Hanbok Jeogori with high fitness capabilities to provide basic data for the development of the modified Hanbok Jeogori pattern for the academic and industrial fields. In this study, the representative modified Hanbok design which most frequently appeared in broadcasting ads and on line was selected. The wearing test was conducted by six professionals, and three times wearing tests were implemented based on 17 evaluation items. The data for this study was processed statistically using SAS 9.0. We conducted, the F-test for significance verification, the Duncan-test for a post test, and a correlation analysis of Cronbach's alpha coefficient for a reliability test of dressing test results were implemented for each of the three tests. The pattern of the developed modified Hanbok Jeogori overcame the defects of the short length of the conventional modified hanbok, and could fix the length issue. The developed Hanbok pattern solved the overlapping problem of the shoulder, back neck point-sleeve length(Whajang), and armhole, displayed in a straight line from the Godae point of the previous modified Hanbok; it suggested the position of the Seop and neck line in the basic bodice. Based on this, the Seop width, Git form, Goreum and the width, length, and position of the string whose dimensions can differ in accordance with the trend can be applied in various forms.

Gene Expression in Zn-deficient U937 Cell Line : Using cDNA Microarray (아연결핍된 단핵구 U937 Cell Line에 있어서의 유전자 발현 탐색 : cDNA Microarray 기법 이용)

  • Beattie, John H.;Trayhurn, Paul
    • Journal of Nutrition and Health
    • /
    • v.35 no.10
    • /
    • pp.1053-1059
    • /
    • 2002
  • In post-genome period, the technique for identifying gene expression has been changed to high throughput screening. In the field of molecular nutrition, the need for this technique to clarify molecular function of the specific nutrient is essential. In this study, we have tested the zinc-regulated gene expression in zinc-deficient U937 cells, using cDNA microarray which is the cutting-edge technique to screen large numbers of gene expression simultaneously. The study result can be used for the preliminary gene screening data for clarifying, using monocyte U937 cell line, molecular Zn aspect in atherosclerosis. U937 cells were cultured in Zn-adequate (control, 12 $\mu$M Zn) or Zn-deficient (experimental, 0 $\mu$M Zn) ESMI media during 2 days, respectively. Cells were harvested and RNA was extracted. Total RNA was reverse-transcriptinized and synthesized cDNA probe labeled with Cy-3. fluorescent labeled cDNA probe was applied to microarray slide for hybridization slide, and after then, the slide was scanned using fluorescence scanner. ‘Highly expressed genes’ in Zn-deficient U937 cells, comparing to Zn-adequate group, are mainly about the genes for motility protein, immune system protein, oncogene and tumor suppressor and ‘Less highly expressed genes’ are about the genes for transcription, apoptosis associated protein, cell cycle, and several basic transcription factors. The results of this preliminary study imply the effectiveness of cDNA microarray for expression profiling of a singly nutrient deficiency, specially Zn. Furthur study, using tailored-cDNA array and capillary endothelial cell lines, would be beneficial to clarify molecular Zn function, more in detail.

A Study of Roughness Measurement of Rock Discontinuities Using a Confocal Laser Scanning Microscope (콘포컬 레이저 현미경을 이용한 불연속면의 거칠기 측정 연구)

  • Byung Gon Chae;Jae Yong Song;Gyo Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.405-419
    • /
    • 2002
  • Fracture roughness of rock specimens is observed by a new confocal laser scanning microscope (CLSM; Olympus OLS1100). The wave length of laser is 488 nm, and the laser scanning is managed by a light polarization method using two galvano-meter scanner mirrors. The function of laser reflection auto-focusing enables us to measure line data fast and precisely. The system improves resolution in the light axis (namely z) direction because of the confocal optics. Using the CLSM, it is Possible to measure a specimen of the size up to $10{\;}{\times}{\;}10{\;}cm$ which is fixed on a specially designed stage. A sampling is managed in a spacing $2.5{\;}\mu\textrm{m}$ along x and y directions. The highest measurement resolution of z direction is $10{\;}\mu\textrm{m}$, which is more accurate than other methods. Core specimens of coarse and fine grained granite are provided. Fractures are artificially maneuvered by a Brazilian test method. Measurements are performed along three scan lines on each fracture surface. The measured data are represented as 2-D and 3-D digital images showing detailed features of roughness. Line profiles of the coarse granites represent more frequent change of undulation than those of the fine granite. Spectral analyses by the fast Fourier transform (FFT) are performed to characterize the roughness data quantitatively and to identify influential frequency of roughness. The FFT results suggest that a specimen loaded by large and low frequency energy tends to have high values of undulation change and large wave length of fracture roughness.