• 제목/요약/키워드: Line scanner

검색결과 141건 처리시간 0.027초

강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상 (Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies)

  • 정순욱;박희명;한숙희;윤정희;한홍율
    • 한국임상수의학회지
    • /
    • 제11권2호
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

신발 접착제 도포 시스템을 위한 CAD 기반 로봇 오프라인 프로그래밍 (CAD Based Robot Off-line Programming for Shoe Adhesive Application System)

  • 윤중선;차동혁;김진영
    • 제어로봇시스템학회논문지
    • /
    • 제10권7호
    • /
    • pp.643-648
    • /
    • 2004
  • Most of shoes manufacturing processes are not yet automated, which puts restrictions on the increase of productivity. Among them, adhesive application processes particularly are holding the most workers and working hours. In addition, its working conditions are very poor due to the toxicity of adhesive agents. In case of automating adhesive application processes by using robots, the robot teaching by playback is difficult to produce high productivity because the kinds of shoes to be taught mount up to several thousands. Therefore, it is essential to generate the robot working paths automatically according to the kind, the size, and the right and left of shoes, and also to teach them to the robot automatically. This study deals with automated adhesive spraying to shoe outsoles and uppers by using a robot, and develops the program to generate three-dimensional robot working paths off-line based on CAD data. First, the three-dimensional data of an outsole outline or an upper profiling line are extracted from the two-dimensional CAD drawing file or the three-dimensional scanner. Next, based on the extracted data and the nozzle conditions for adhesive spraying, a robot working path is generated automatically. This research work is the core in automating adhesive spraying processes, and will do much for increasing productivity of shoes manufacturing.

신경망을 이용한 칼라 입력장치의 칼라 보정 (Color correction of tile color input device using the Neural Network)

  • 엄경배;안창선
    • 정보교육학회논문지
    • /
    • 제3권1호
    • /
    • pp.134-142
    • /
    • 1999
  • 칼라 입출력 장비의 가격이 점차로 저렴해짐에 따라 영상으로부터 물체의 형상뿐만아니라 칼라까지도 인식하여 보다 정밀한 정보를 이용하고자하는 요구가 증대되고 있다. 이를 위해서는 칼라 입출력 시스템의 정확한 칼라 표현 및 재현을 위해 칼라 보정에 관한 연구가 선행되어져야한다. 따라서, 본 논문에서는 칼라 입출력장비 중 칼라 스캐너의 칼라 보정에 관하여 연구하였다. 칼라 스캐너의 특성은 gray-balancing과 칼라 변환의 두과정을 나뉜다. 칼라 변환으로부터 gray-balancing을 분리함으로써 칼라 변환을 위해 유도되어진 변환 행렬은 모든 형태의 스캐너에 적용될 수 있어 스캐너 특성의 portability를 가능하게 한다. 또한, gray-balance된 RGB값을 얻기위한 선의 적합을 위해 최소자승법을 이용하였고, 칼라 변환을 위해 gray-balance된 RGB로부터 CIE-XYZ로 비선형적 좌표 변환 문제를 저장공간이 많이 필요하지 않고, 빠른 변환결과를 제공할 수 있는 장점이 있는 신경망 기법을 이용하여 해결 하였다. 삼차원 3자극치 공간에서 신경망 출력은 원하는 출력의 근사치를 제공하는 것을 알 수 있었다. 제안된 칼라 보정 방법은 모듈별로 분해되었기 때문에 스캐너 특성의 portability를 가능하게 하여 모든 형태의 스캐너 보정에 이용될 수 있으리라 기대된다.

  • PDF

2D-3D 정합기반 실제 제품의 사실적 3D 모델 생성 (Realistic 3D model generation of a real product based on 2D-3D registration)

  • 김강연;손성민
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5385-5391
    • /
    • 2013
  • 온라인을 기반한 제품의 구매가 활성화 됨에 따라, 소비자들의 제품 디자인에 대한 사실적이고 정확한 정보를 요구하고 있다. 본 연구에서는 제품의 형상정보(3D mesh)와 색/질감정보(image)를 이용하여 텍스쳐 맵핑된 실사적 3차원 모델을 생성하는 효율적인 방법을 제안한다. 3 차원 형상정보에 대응하는 이미지 상의 텍스쳐 좌표 관계를 구하기 위해 오브젝트 좌표계와 카메라 좌표계 사이의 변환행렬, 카메라의 초점거리, 카메라 CCD 와 프레임상의 이미지 사이의 종횡비를 파라미터로 하는 2D-3D 정합을 수행한다. 이러한 2D-3D 정합에 있어 발생하는 연산의 복잡도와 비선형도를 낮추기 위하여, 카메라 내부파라미터 검정단계, 임의의 회전행렬에 대한 임시적 최적 이동 벡터 (TOTV), 회전행렬에 대한 비선형 최적화 단계로 접근한다. 제안하는 방법의 유용성을 시현하기 위해 3차원 컬러 측정기로는 색외관을 획득하기 힘든 메탈릭 페인트 재질로 이루어진 제품에 적용한 구현결과를 보인다.

얼굴스캐너를 활용한 안면형상 영상진단기의 기초 연구 (Basic Study on the Image Instrument of the Facial-form by the 3D-facial Scanner)

  • 김경철;이정원;김훈;신순식;이해웅;이용태;지규용;김종원
    • 동의생리병리학회지
    • /
    • 제22권2호
    • /
    • pp.497-501
    • /
    • 2008
  • 3D facial scanner for an accurate analysis is measured precisely a distance in straight, a distance in curved line, an angle in 3D data, the area of surface. We can easy acquire 3D data by the method of 0.8sec in each scan with easy handling, simple merge to whole face, harmless and fast process. In the HyungSang medicine, the inspection of the facial shape includes the Dam(gall bladder) - Bang Kwang(urinary bladder) body, the Jung${\cdot}$Gi${\cdot}$Shin${\cdot}$Hyul, the six merdian types etc. And we will collect the evidence based date verifing in the HyungSang clinical medicine. As we will analyze the facial whole form and the size${\cdot}$length${\cdot}$angle of the facial part, put the facial form's standardization on a solid foundation.

안면 수기 마사지 후 안모의 변화 (The Change of Facial Contouring after Facial Massage)

  • 임은진;위수영;정다운;김성택
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.103-108
    • /
    • 2012
  • 본 연구는 안면수기 마사지 시술 후 얼굴 부피 및 두께의 안모 변화를 평가하기 위해 20~40대 여성 10명을 선정하여 주 2회, 20회의 시술을 10주간 진행하였으며, Vivid 9i$^{(R)}$ laser scanner(Minolta, Tokyo, Japan)를 사용해서 마사지 관리 전과 마사지 관리 후의 부피 변화를 비교하였다. 결과, 수기 마사지 후 얼굴 부피는 평균 $731mm^3$ 정도로 다소 감소하였으며(p>.05), 광대뼈 부위의 두께는 평균 0.40mm로 감소하였고(p<.05) 저작 부위의 두께 변화는 평균 0.44mm로 감소하였다(p<.05) 이에 얼굴 수기마사지에 의한 안모 변화는 부피와 광대뼈 및 저작 부위에서 변화가 나타났음을 알 수 있다. 이는 비침습적이면서 비교적 안전한 방법으로 비대칭 및 저작근 비대 등으로 인한 얼굴형 변화를 개선하는데 긍정적 효과를 줄 것으로 사료된다.

A Study on Changes to the Upper Body Shape of Elderly Japanese Women -Analysis of the Transverse Plane by Age Group-

  • Oh, Hee-Kyoung
    • 한국의류학회지
    • /
    • 제42권4호
    • /
    • pp.726-736
    • /
    • 2018
  • This study determined how the upper body shape of elderly women changes with age in order to improve the fit of clothing worn by elderly women. Thirty-nine healthy elderly Japanese women had their body measurements taken by measuring tape and a 3D body line scanner (Hamamatsu Model #C9036-02) from December 2011 to March 2012 at a university in Tokyo. It was found that the shoulder line shortens in women between the ages of 70 and 74, but that the upper arm lengthens in women between the ages of 75 and 79. It was also found that the upper part of the scapular area rolls forward in women between the ages of 70 and 74, and that the point of the back which protrudes the most-the lower scapular area-rolls forward in women between the ages of 75 and 79. The results will be helpful for designing clothes for elderly women as their body shape changes with age.

실시간 품질관리 정보시스템 개발사례

  • 문정;이동활;류승수;손기목;채우병;양이근;범진성;류원택
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1991년도 추계학술대회 논문집
    • /
    • pp.191-193
    • /
    • 1991
  • This paper is described about the on-line, real-time quality information management system as the infrastructure of CIM, which we developed for the full automatic washing machine assembly line. This System is composed of Ethernet LAN, RS-485 Network, POP terminal, BAR CODE Scanner, PLC, ROBOT, measuring equipments and real-time processing software. We will run this system from next month regularly.

  • PDF

2차원 레이저 레이진 파이더를 이용한 빠른 로컬 실내 지도 제작 (Fast Local Indoor Map Building Using a 2D Laser Range Finder)

  • 최웅;고낙용;최정상
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.99-104
    • /
    • 1999
  • This paper proposes an efficient method constructing a local map using the data of a scanning laser range finder. A laser range finder yields distance data of polar form, that is, distance data corresponding to every scanning directions. So, the data consists of directional angle and distance. We propose a new method to find a line fitting with a set of such data. The method uses Log-Hough Transformation. Usually, map building from these data requires some transformations between different coordinate systems. The new method alleviates such complication. Also, the method simplifies computation for line recognition and eliminates the slope quantization problems inherent in the classical Cartesian Hough transform method. To show the efficiency of the proposed method, it is applied to find a local map using the data from a laser range finder PLS(Proximity Laser Scanner, made by SICK).

  • PDF

전차선 편위 및 높이 측정 시스템 개발에 관한 연구 (A Study on the Development of Catenary stagger and height Measurement System)

  • 송성근;박성모
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.299-304
    • /
    • 2008
  • Catenary and Pantograph are a power supply devices for electric trains and shall be steadily contacted. Rail catenary must be installed precisely and managed for stable train operations. But external factors such as weathers, nature, etc., or aging affect catenary geometry. Changed catenary height causes high voltage spark or instant electric disconnection. Big spark and disconnection damage pantograph shoe and catenary coating and might interrupt rail operations. To prevent a big scale spark or electric disconnection catenary maintenance shall be required with catenary geometry measurement systems. In this paper, we describe the development of catenary height and stagger measurement system. The catenary height and stagger measurement system uses Acuity company's AR4000 Range Finder for distance measurement and AccuRange Line Scanner for degree measurement. This system reports suspicious overhead line sections with excessive height and stagger variance.

  • PDF