• Title/Summary/Keyword: Line scanner

Search Result 141, Processing Time 0.026 seconds

Engineering design process of tight-fit sportswear using 3D information of dermatomes and skin deformation in dynamic posture (동적자세와 피부분절을 이용한 기능성 밀착의복 제작 프로세스)

  • Kim, So-Young;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.21 no.3
    • /
    • pp.551-565
    • /
    • 2012
  • The primary goal of this study was to provide a systematic methodology of utilizing 3D technology for tight-fit performance sportswear using information of skin deformation in various posture. Technical tools used in this study are Cyberware whole body scanner, RapidForm2004, 2C-AN 3D pattern development program, and YukaCAD. Analysis of the 3D skin deformation while knee joint was bent from $0^{\circ}$ to $60^{\circ}$ revealed that the length of dermatomes L4 was remained consistent during knee bending. Therefore, L4 was chosen as a major cutting line. To develop a highly ergonomic pattern, replicas of static and dynamic postures were developed and integrated using two methods, one is morphing method (Sqirlz Morph), and the other is AutoCAD. Experimental tight-fit garments called 'Derm-Mov Pattern' was designed using dematomes L4, L2, and inner line under knee and compared with four other patterns. As results, AutoCAD was appropriate as a integrating method of various postures. In wear test, 'Derm-Mov Pattern' was rated high (p < .001), in terms of pressure comfort especially around front crotch area. However, wear sensation was not signipicantly different in other area due to highly extensible property of materials. Pressure distribution was relatively even in these experimental garments.

Matching for Cylinder Shape in Point Cloud Using Random Sample Consensus (Random Sample Consensus를 이용한 포인트 클라우드 실린더 형태 매칭)

  • Jin, YoungHoon
    • Journal of KIISE
    • /
    • v.43 no.5
    • /
    • pp.562-568
    • /
    • 2016
  • Point cloud data can be expressed in a specific coordinate system of a data set with a large number of points, to represent any form that generally has different characteristics in the three-dimensional coordinate space. This paper is aimed at finding a cylindrical pipe in the point cloud of the three-dimensional coordinate system using RANSAC, which is faster than the conventional Hough Transform method. In this study, the proposed cylindrical pipe is estimated by combining the results of parameters based on two mathematical models. The two kinds of mathematical models include a sphere and line, searching the sphere center point and radius in the cylinder, and detecting the cylinder with straightening of center. This method can match cylindrical pipe with relative accuracy; furthermore, the process is rapid except for normal estimation and segmentation. Quick cylinders matching could benefit from laser scanning and reverse engineering construction sectors that require pipe real-time estimates.

A implementation of system which checks the vehicle oil identification and quantitative gas (자동차 석유 및 정량주유 체크 시스템의 구현)

  • Jeong, Da-Woon;Baek, Sung-Hyun;Jang, Jong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1277-1282
    • /
    • 2011
  • Recently, many car drivers were damaged by gas station which support similar oil product and not quantitative gas. It were expected to increase above-mentioned damages. By using similar oil products, caused damage are working of lubrication in the fuel line, elf-cleaning function, the part of the early deterioration, impure accumulation in the fuel line, toxicity material in exhaust emissions and unidentified chemical reaction. To prevent these damages, proposed system use in-vehicle state data with OBD-II protocol, measure quantitative gas and similar oil. In this paper, there have implemented similar oil identification and quantitative gas system through OBD-II scanner to provide WiFi communcation by using WinCe development Board.

Epipolar Resampling for High Resolution Satellite Imagery Based on Parallel Projection (평행투영 기반의 고해상도 위성영상 에피폴라 재배열)

  • Noh, Myoung-Jong;Cho, Woo-Sug;Chang, Hwi-Jeong;Jeong, Ji-Yeon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.4
    • /
    • pp.81-88
    • /
    • 2007
  • The geometry of satellite image captured by linear CCD sensor is different from that of frame camera image. The fact that the exterior orientation parameters for satellite image with linear CCD sensor varies from scan line by scan line, causes the difference of image geometry between frame and linear CCD sensor. Therefore, we need the epipolar geometry for linear CCD image which differs from that of frame camera image. In this paper, we proposed a method of resampling linear CCD satellite image in epipolar geometry under the assumption that image is not formed in perspective projection but in parallel projection, and the sensor model is a 2D affine sensor model based on parallel projection. For the experiment, IKONOS stereo images, which are high resolution linear CCD images, were used and tested. As results, the spatial accuracy of 2D affine sensor model is investigated and the accuracy of epipolar resampled image with RFM was presented.

  • PDF

Effect of drill radius setting on prosthesis machining (드릴 반경 설정이 보철물 가공에 미치는 영향)

  • Kim, Chong-Myeong;Kim, So-Ri;Cho, Mi-hyang
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the trueness and fitness of machined prostheses according to drill radius setting in CAD software. Methods: For this study, standard abutment were replicated in Type IV stone. The stone abutment were scanned using a dental scanner. The CAD design software was designed using scanned abutment data. When designing, the drill radius was set to 0.3 mm and 0 mm, respectively, and saved. The saved design data was milled using a milling machine (n=13). The inner surface of the milled crown was scanned. The trueness and fitness were measured using the inner scan data of prostheses. Independent t-tests were performed to identify significant differences in each data. Results: Trueness values of the data saved with 0.3 mm and 0 mm drill radius were $18.9{\pm}2.3{\mu}m$ and $19.1{\pm}0.9{\mu}m$, respectively. There was no statistically significant difference between the groups. Fitness values of the data saved with 0.3 mm and 0 mm drill radius were $65.5{\pm}0.8{\mu}m$ and $33.8{\pm}1.0{\mu}m$, respectively. There was a statistically significant difference between the groups (p<.05). Conclusion : Setting the drill radius is important to produce clinically good fit prostheses.

Three-dimensional morphometric study on the retromolar pad

  • Min-Sang Cha;Dae-Gon Kim;Yoon-Hyuk Huh;Lee-Ra Cho;Chan-Jin Park
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.302-314
    • /
    • 2023
  • PURPOSE. The aim of this study was to classify the shapes of retromolar pads and assess their morphometric differences using a 3D model. MATERIALS AND METHODS. Two hundred fully edentulous or Kennedy Class I partially edentulous patients (400 retromolar pads) were enrolled. Scan data of the definitive mandibular casts produced through functional impressions were obtained using a 3D laser scanner. Seven parameters (transverse diameter, longitudinal diameter, transverse-contour length, longitudinal-contour length, longitudinal/transverse diameter ratio, longitudinal/transverse-contour length ratio, and angle of the retromolar pad line to the residual alveolar ridge line) were measured using image analysis software. Subsequently, the pads were classified according to the shape. Statistical analyses were performed using 95% confidence intervals. RESULTS. Classifying the retromolar pads into three shapes led to high intra-examiner reliability (Cronbach's alpha = 0.933). The pear shape was the most common (56.5%), followed by oval/round (27.7%) and triangular (15.8%) shapes. There were no significant differences between the left and right sides according to the shape and no significant differences in any parameter according to age. The transverse diameter and longitudinal/transverse diameter ratio differed between sexes (P < .05). The triangular shape had a significantly different transverse diameter, transverse-contour length, longitudinal/transverse diameter ratio, and longitudinal/transverse-contour length ratio compared with the pear and oval/round shapes (P < .05). CONCLUSION. From a clinical reliability standpoint, classifying retromolar pads into three shapes (oval/round, pear-shaped, and triangular) is effective. The differences in the sizes among the shapes were attributed to the transverse measurement values.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Performance Measurement of Siemens Inveon PET Scanner for Small Animal Imaging (소동물 영상을 위한 Siemens Inveon PET 스캐너의 성능평가)

  • Yu, A-Ram;Kim, Jin-Su;Kim, Kyeong-Min;Lee, Young-Sub;Kim, Jong-Guk;Woo, Sang-Keun;Park, Ji-Ae;Kim, Hee-Joung;Cheon, Gi-Jeong
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Inveon PET is a recently developed preclinical PET system for small animal. This study was conducted to measure the performance of Inveon PET as recommended by the NEMA NU 4-2008. We measured the spatial resolution, the sensitivity, the scatter fraction and the NECR using a F-18 source. A 3.432 ns coincidence window was used. A $1\;mm^3$ sized F-18 point source was used for the measurement of spatial resolution within an energy window of 350~625 keV. PET acquisition was performed to obtain the spatial resolution from the center to the 5 cm offset toward the edge of the transverse FOV. Sensitivity, scatter fraction, and NECR were measured within an energy window of 350~750 keV. For measuring the sensitivity, a F-18 line source (length: 12.7 cm) was used with concentric 5 aluminum tubes. For the acquisition of the scatter fraction and the NECR, two NEMA scatter phantoms (rat: 50 mm in diameter, 150 mm in length; mouse: 25 mm in diameter, 70 mm in length) were used and the data for 14 half-lives (25.6 hr) was obtained using the F-18 line source (rat: 316 MBq, mouse: 206 MBq). The spatial resolution of the F-18 point source was 1.53, 1.50 and 2.33 mm in the radial, tangential and axial directions, respectively. The volumetric resolution was $5.43\;mm^3$ in the center. The absolute sensitivity was 6.61%. The peak NECR was 486 kcps @121 MBq (rat phantom), and 1056 kcps @128 MBq (mouse phantom). The values of the scatter fraction were 20.59% and 7.93% in the rat and mouse phantoms, respectively. The performances of the Inveon animal PET scanner were measured in this study. This scanner will be useful for animal imaging.

A Study on the Machining of Sculptured Surfaces by 5-Axis CNC Milling (ll) The Prediction of Cusp Heights and Determination of Tool Path interval (5-축 CNC 밀링으로의 자유곡면 가공에 관한 연구 (II) 커섭 높이 예측과 공구경로 결정)

  • 조현덕;전용태;양민양
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.8
    • /
    • pp.2012-2022
    • /
    • 1993
  • For the machining of the sculptured surfaces on 5-axis CNC milling machine, the milling cutter direction vector was determined in the study (I) with 5-axis post-processing. Thus, it was possible to cut the sculptured surfaces on five-axis CNC milling machine with the end mill cutter. Then, for smooth machined surfaces in five-axis machining of free-from surfaces, this study develops an algorithm for prediction of cusp heights. Also, it generates tool path such that the cusp heights are constrained to a constant value or under a certain value. For prediction of the cusp height between two basis points, a common plane, containing the line crossing two basis points and the summation vector of two normal vectors at two basis points, is defined. The cusp height is the maximum value of scallops on the common plane after end mill cutter passes through the common plane. Sculptured surfaces were machined with CINCINNATI MILACRON 5-axis machining center, model 20V-80, using end mill cutter. Cusp heights were verified by 3-dimensional measuring machine with laser scanner, WEGU Messtechnik GmbH.

Continuous Scanning Method for Improvement of Precision and Fabrication Efficiency of Two-Photon Stereolithography (연속적 스캐닝 방법을 이용한 이광자 광중합 공정의 제작 속도 및 정밀도 개선에 관한 연구)

  • Lim, Tae-Woo;Son, Yong;Yang, Dong-Yol;Kong, Hong-Jin;Lee, Kwang-Sup;Park, Sang-Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.396-401
    • /
    • 2008
  • Minimization of processing time in two-photon stereolithography (TPS) has been one of important issues. Generally, a voxel scanning method (VSM) has been used in TPS because the method is very profitable for the stable fabrication irrespective of jittering and response time of scanning equipments such as a stage and a galvano-scanner. However, supplementary processing time due to the on/off control of a shutter for the generation of each voxel is required inevitably in VSM; by this reason, much processing time takes to fabricate largescale micropatterns and three-dimensional patterns. In this work, a continuous scanning method (CSM), generating patterns by movement of beam focus with a constant speed, is proposed for the improvements of scanning speed and precision in TPS. Some line patterns are fabricated by each scanning method to demonstrate the usefulness of CSM with viewpoints of scanning speed and precision.