• Title/Summary/Keyword: Line harmonic

Search Result 474, Processing Time 0.03 seconds

Design of Highly Linear Power Amplifier using Bandpass Filter based on Metamaterial Structure (Metamaterial 구조의 대역통과여파기를 이용한 WCDMA 대역 고선형 전력증폭기 설계)

  • Kim, Hyoung-Jun;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.68-72
    • /
    • 2012
  • In this paper, highly linear power amplifier using bandpass filter based on metamaterial and Composite Right- / Left-Handed (CRLH) structure is proposed. The proposed bandpass filter consist of the series capacitor, series microstrip line and the parallel inductor, parallel microstrip line. The insertion loss is minimized at operation frequency and the $2^{nd}$ harmonic is suppressed by the bandpass filter using the CRLH structure. And we improved the Adjacent Channel Leakage Ratio (ACLR) using the characteristic of the proposed bandpass filter. At 2.14 GHz, we have obtained the output power of 38.83 dBm, the $2^{nd}$ harmonic of .61.33 dBc, the $3^{rd}$ IMD of .54.67 dBc, and ACLR of .51.33 dBc at 5 MHz offset, -56.50 dBc at 10 MHz offset, respectively.

Efficiency and Power Factor Improvement of Induction Motor Using Single-Phase Back Rectifier (단상 강압 정류기를 이용한 유도전동기의 효율 및 역률 개선)

  • 문상필;이현우;서기영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.22-29
    • /
    • 2002
  • Usually, much harmonics are included and cause harmonic loss of motor, torque pulsation, electro-magnetic noise and shock etc. by switching function of inverter when drive induction motor variableness inside. It applied partial resonant Buck converter and three phase voltage type SPWM inverter circuit to induction motor driving system in this paper that see to solve such problem. Changed operation condition variously to do input current of circuit that propose sine-wave by unit power factor almost and capacitor supplied bringing back to life voltage by power supply arranging properly assistance diode and electric power switching. Power factor and efficiency improved as that minimize variation of input at power supply voltage polarity reverse by that add voltage reversal function. Also, by using output filter, reduced harmonic of output line to line voltage components, and introduce state space analysis and forecast operation of rectifier. Such all items confirmed validity through simulation and an experiment.

A Study on the High Performance Slip Power Recovery System in Induction Motor (유도전동기의 고성능 슬립전력 회수방식에 대한 연구)

  • Park, Han-Ung;Park, Seong-Jin;An, Jin-U;Park, Jin-Gil;Kim, Cheol-U;Hwang, Myeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.431-439
    • /
    • 1999
  • Among the variable-speed AC motor drive systems, the static slip power recovery system has been widely adopted in large power drives because a high efficiency drive can be obtained by recovering the slip power to the AC line. Although many improvements have been made in this system, several problems also remain such as the need of transformer in inverter AC side, which results in limiting speed control range and increasing the losses, production of reactive power by the control of inverter firing angle, harmonics in line currents, and so on. This paper presents the novel high performance slip power recovery system using the boost converter and small size filter in the rotor circuit, which recovers slip power of a wound rotor induction machine to AC supply efficiently with the aid of the boost converter, in which most of the problems in conventional system can be solved. The speed can be controlled by the duty ratio of the converter switch, not by inverter firing angle. As a results, the proposed system can operate in high power factor and the harmonic currents caused by the inverter and rectifier can be considerably suppressed. The validity of the proposed system verified by demonstrating the good agreement in the simulation and experimental results.

  • PDF

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

A New Slip Power Recovery System by Switch Mode Converter (스위치모드 컨버터에 의한 새로운 슬립전력 회수시스템)

  • 박한웅;박성준;김철우;황영문
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.73-81
    • /
    • 1999
  • A new slip power recovery system applying a switch mode converter to the rotor circuit of the wound rotor induction machine is proposed and investigated in this paper. With the analysis of the steady-state performances of the proposed system, it can be shown that the speed can be controlled by the duty ratio of the converter switch and the several characteristics of a conventional system can be also improved. In particular, the low power factor and the harmonic components in the line current, which are the main disadvantages of the conventional system, is significantly improved, and linear speed regulation can be obtained. Theoretical and experimental results are presented and illustrated to demonstrate the satisfactory working of the proposed system.

A Study on the Single-Stage Two-Switch Forward Converter (단일전력단 Two-Switch Forward 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.60-66
    • /
    • 2005
  • This paper presents the single-stage TSFC(Two-Switch Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contests of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations is illustrated and verified through the experiment with a 200[W](5[V], 40[A]) 100[kHz] MOSFET based experimental circuit.

Some precautions to consider in using wavelet transformation for damage detection analysis of plates

  • Beheshti-Aval, S.B.;Taherinasab, M.;Noori, M.
    • Smart Structures and Systems
    • /
    • v.11 no.1
    • /
    • pp.35-51
    • /
    • 2013
  • Over the last two decades Wavelet Transformation (WT) method has been widely utilized for the damage identification of structures. The main objective of this paper is to discuss and present some of common shortcomings and limitations of mathematical software, as well as other precautionary measures that need to be considered when using them for wavelet analysis applications. Due to popular usage of MATLABMATLAB(R) comparing to other mathematical tools among researchers for data processing of structural responses through WT analysis, this software was chosen for specific study. To the best of the authors' knowledge, these limitations and observations have not been previously identified or discussed in the literature. In this work, a square plate with a severe damage, in form of a crack, parallel to the left edge of the plate is selected for a pilot study. The steady state harmonic response is used for measuring the deflection shape across the line parallel to one edge and perpendicular to the damage. Several criteria and cases such as the smallest size damage that can be detected, correlation between the crack width and the number of sampling points, and the influence of the damage thickness on the accuracy of the result are investigated.

EFFECT OF IN-SITU VIBRATION ON THE PROPERTIES OF A-GRADE STEEL SMA WELDMENT

  • Park, Tae-Dong;Kim, Ha-Geun;Youn, Joong-Geun
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.408-411
    • /
    • 2002
  • Effect of in-situ vibration on the properties of A-grade steel SMA weldment has been investigated. Welding was performed on the steel fixed at the experimental jig under the mechanical vibration of a given frequency. The applied frequency varied from 39 to 43.5 Hz (harmonic frequency). For weldments formed under the vibration with a sub-harmonic frequency, both the columnar width of the weld metal and the prior austenite grain size of the HAZ near the fusion line clearly decreased. This indicates that the vibration increase the cooling rate after welding. Vibration effect was also found at the weld metal formed at the center region of the weldment. The weld metal showed liner microstructure both in columnar zone and in equiaxed zone with thinner grain boundary ferrite. However mechanical properties of the weld metal did not exactly follow the microstructural changes developed under the vibration. The weld metal formed under the vibration revealed higher yield and tensile strength but lower ductility and impact toughness, compared with the conventional weld metal.

  • PDF

Direction for Development of Energy Regeneration Device for DC Electric Railway System (DC전철구간의 에너지회생장치 개발 방향)

  • Kim, Yong-Ki;Bae, Chang-Han;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

The THD measurement of HEP equipment power installed on 8200 series Electric locomotive (8200대 신형 전기기관차 HEP 장치 고조파 왜율 측정)

  • Kim, Dae-Sung;Lee, Kyung-Rac;Ahn, Hong-Goan;Park, Jong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.488-497
    • /
    • 2010
  • 8100 series Electric locomotive was imported from SIEMENS of Germany on 2001. 8100 series model is modified from BR152 model to be complied with national environment. After 8100 series Electric locomotive carried out main line test for long time, 8200 series Electric locomotive produced in 10 locomotives with improvement and supplement on some parts. the one of supplement is to install the HEP equipment. In paper, about total harmonic distortion of HEP equipment power, it compares the result of combination with the result of actual measurement. It checks whether the measurement meets the specification of design or not. And it describes international standard about total harmonic distortion of supply system.

  • PDF