• Title/Summary/Keyword: Line harmonic

Search Result 474, Processing Time 0.029 seconds

A study On the Switching Technique of Boost Converter for Harmonic Reduction (부스트컨버터의 고조파저감을 위한 스위칭 기법에 관한 연구)

  • Shon, Jin-Geun;Chu, Sun-Nam;Kim, Young-Hyuk;Lee, Sang-Cheol;Lee, Bok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.74-78
    • /
    • 2000
  • In this paper a switching control circuit for shaping the line current and reducing the total harmonics distortion in the boost converter is presented. To solve the problems of performance degradation due to pulse waveform in the input current, the boost converter in which the harmonic distortion in the input current is reduced using a 3th harmonic-injected PWM is proposed. Finally, Simulation and experimental results of boost converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

Harmonic Reduction of Three-Phase Boost Rectifier using a Harmonic- Injected (고조파 주입 펄스 폭 변조를 이용한 3상 부스트 정류기의 고조파 저감)

  • Lee, Joon-Ku;Kim, Jin-Sung;Park, Seok-Ha;Kim, Jong-Bum;Kim, Gwang-Su;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2736-2738
    • /
    • 1999
  • Power electronic loads inject harmonic currents into the utility system. The large increase of power consumption will inevitably lead to deteriorating power quality due to the popularization of switch-mode power electronic equipment. In this paper, a periodic voltage is injected in the control circuit to vary duty cycle of the rectifier switch within a line cycle so that the fifth-order harmonic of the input current is reduced to meet the IEC 61000-3-2 requirement. Experimental results are presented to confirm the validity of this method.

  • PDF

A Reset-Free Anti-Harmonic Programmable MDLL-Based Frequency Multiplier

  • Park, Geontae;Kim, Hyungtak;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.459-464
    • /
    • 2013
  • A reset-free anti-harmonic programmable multiplying delay-locked loop (MDLL) that provides flexible integer clock multiplication for high performance clocking applications is presented. The proposed MDLL removes harmonic locking problems by utilizing a simple harmonic lock detector and control logic, which allows this MDLL to change the input clock frequency and multiplication factor during operation without the use of start-up circuitry and external reset. A programmable voltage controlled delay line (VCDL) is utilized to achieve a wide operating frequency range from 80 MHz to 1.2 GHz with a multiplication factor of 4, 5, 8, 10, 16 and 20. This MDLL achieves a measured peak-to-peak jitter of 20 ps at 1.2 GHz.

A Design of Miniaturized Ring-Hybrid Coupler with Broadband Harmonic Attenuation Property (광대역 고조파 감쇠특성을 갖는 소형화된 링-하이브리드의 설계)

  • Lee Hong-Seop;Choi Kyoung;Hwang Hee-Yong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.197-201
    • /
    • 2006
  • Folded lines are applied to design a compact microstrip ring hybrid. Using the proposed structure we achieve both significant size reduction and good harmonic suppression with the same results of conventional ring hybrid at 2.41GHz. Including the third harmonic frequency, up to 11GHz band harmonics are suppressed to -20dB. The size of the proposed ring-hybrid is reduced to one forth of the conventional ring hybrid. The measured frequency responses agree well with simulated ones.

  • PDF

Analysis and Measurement of Current Harmonics Due to Non-linear Load in Low Voltage System (저압 시스템에서 비선형 부하의 사용에 따른 전류 고조파 해석 및 측정)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.601-608
    • /
    • 2001
  • The ever increasing density of adjustable speed drives(ASD) device with non-linear operating characteristics has been to put tremendous harmonic stress on end user's electrical application. All ASD controllers which employ solid state power devices cause harmonic currents in the source side line. This paper describes harmonic problems for use of ASD. In order to investigate the effect of harmonics caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current waveforms. Measurement results show that additional operation of linear load at the parallel bus with nonlinear load such as ASD is helpful to the reduction of harmonic influence.

  • PDF

The Analysis of the Parallel Coupled Line with an Open Stub and Its Branch-Line Hybrid Application (개방 스터브를 갖는 평행 결합 선로의 해석과 브랜치 라인 하이브리드에의 응용)

  • Lee, Won-Kyun;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • In this paper, the exact analysis of the parallel coupled line with open stub and an application to branch-line hybrid are presented. The Z-parameter of the parallel coupled line with an open stub is derived. The structure shows the characteristics as a lowpass filter unit cell(LUC) with wide stop band. Using the characteristics we designed a miniaturized branch-line hybrid with wide harmonic-suppressed band. The size of the new branch-line hybrid is a half of the conventional branch-line hybrid. The frequency response is the same with that of the conventional one near 1.7 GHz center frequency. Including the fifth harmonics, up to 12 GHz spurious responses are suppressed below to -20dB.

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.

MR Line Scan Angiography using Spectral Analysis

  • Jung, Kwan-Jin;Ro, Yong-Man;Sim, Bog-Tae;Ra, Jong-Beom;Cho, Zang-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.27-28
    • /
    • 1989
  • In conventional line scan angiography, flow signal has been enhanced by the time_of_flight effect while the signal from stationary tissues has been suppressed by the saturation rf pulse followed by spoiling gradients. Due to the inhomogeneous rf field and the tissue dependent T1 relaxation time, however, stationary tissues can not be suppressed completely or uniformly, and the remnant stationary signal deteriorates the resultant angiogram. Here, the complete cancellation of stationary tissues is made possible by the spectral analysis of a series of repetitive line images of the same slice. The Fourier transformation of a set of line images results in the spectrum images, where stationary tissues are collected into the dc component while arteries are included in harmonic components because of the variation of the flow velocity and the resultant flow signal in arteries according to the cardiac cycle. The summation of harmonic components excluding the dc component results in the angiogram of arteries with the complete cancellation of stationary tissues.

  • PDF

A Novel Three-Phase Four-Wire Shunt Active Filter to Eliminate Neutral Current (高調波 中性電流를 低減시키기 위한 3相4線 竝列形 能動필터에 關한 硏究)

  • 고경수;김래기;유권종;송진수;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.184-190
    • /
    • 1998
  • Most buildings and factories are supplied with electric power by three-phase four-wire low voltage electric distribution system. This method pollutes the neutral line and utility sources with harmonic currents. Today, development of power conversion technology and the popularization of computer cause the neutral current to become serious. In this paper, a novel three-phase four-wire active filter is proposed to solve these harmonic problems has two purposes. The first purpose of the proposed active filiter is that the phase current has a sinusoidal waveform shape under the nonlinear load. The second purpose of the proposed active filiter is that the current on the neutral line become zero under the unbalanced power source and under the varring load conditions. The ability of the shunt active filiter has been proved to be excellent through simulations under the varring load conditions.

  • PDF

A Study on the Design of Triple-tuned Filter for Line Commutated Converter HVDC (HVDC시스템 적용을 위한 Triple-tuned 필터 설계방법 연구)

  • Lee, Seong-Doo;Choi, Soon-Ho;Kim, Chan-Ki;Cha, HanJu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1288-1296
    • /
    • 2015
  • The ac side current of a line commutated converter(LCC) high voltage direct current (HVDC) is characterized by highly non-sinusoidal waveform. If the harmonic current is allowed to flow in the connected ac network, it may cause unacceptable levels of distortion. Therefore, ac side filters are required as part of the total HVDC converter station, in order to reduce the harmonic distortion of the ac side current and voltage to acceptably low levels. The ac filters are also employed to compensate the requested reactive power because LCC HVDC also consume substantial reactive power. Among different types of filters, triple-tuned filters have been widely utilized for HVDC system. This paper presents two design methods of triple-tuned filter; equivalent method and parametric method. Using a parametric method, in particular this paper proposes a design algorithm for a triple tuned filter. Finally, the performance of the design algorithm is evaluated for a 250kV HVDC system in Jeju island. The results cleary demonstrate the effectiveness of proposed design method in harmonics reduction.