• Title/Summary/Keyword: Line capacity

Search Result 1,075, Processing Time 0.027 seconds

A Cascaded D-STATCOM Integrated with a Distribution Transformer for Medium-voltage Reactive Power Compensation

  • Lei, Ertao;Yin, Xianggen;Chen, Yu;Lai, Jinmu
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.522-532
    • /
    • 2017
  • This paper presents a novel integrated structure for a cascaded distribution static compensator (D-STATCOM) and distribution transformer for medium-voltage reactive power compensation. The cascaded multilevel converter is connected to a system via a group of special designed taps on the primary windings of the Dyn11 connection distribution transformer. The three-phase winding taps are symmetrically arranged and the connection point voltage can be decreased to half of the line-to-line voltage at most. Thus, the voltage stress for the D-STATCOM is reduced and a compromise between the voltage rating and the current rating can be achieved. The spare capacity of the distribution transformer can also be fully used. The working mechanism is explained in detail and a modified control strategy is proposed for reactive power compensation. Finally, both simulation and scaled-down prototype experimental results are provided to verify the feasibility and effectiveness of the proposed connection structure and control strategy.

A Study of Optimization in the Queue, Finite Population (유한모집단 대열기법에 의한 최적화 연구)

  • 오충환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.1 no.1
    • /
    • pp.37-44
    • /
    • 1978
  • The purpose of this study is to search for an efficient application method in solving delay-phenomenon problems which influence upon total production cost through case study. The method of this study is an experimental study based on cutting time data in lead cutting operations from "Lead Cutting Machine (Stripper)" and its service rate data from a large electronic products company which utilizes conveyor line system for the products "Car Stereo" The procedure of this experimental study is as follows; 1) Using loading(Man-Hour) analysis technique j,1 order to analyse and evaluate Production capacity, efficiency, operation and idle rate assembly charge, waiting and service cost -when its are controlled by stripper operator(server) 2) Establishing adequate waiting time model of finite population caused by the interference of 4 stripper machine which is drawn from mathematical statistics testing, that is, goodness of fit test in the waiting and service rate and to search for optimal solution by utilizing the above mentioned model The experimental result was that amount to 8,546,618won Per year was brought down, that is, by optimum point, it shows a decrease as compared with Present point. The major limitation of this experimental study is that the Queue in the Finite Population, so to speak. it comes from the interference of 4 stripper machine dealt with this case were limited only on the Car Stereo conveyor line. Further study of application of this application method to the areas such as material handling, personnel management marketing and transportation management is strong1y recommended.trong1y recommended.

  • PDF

Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable (초전도 케이블의 Quench 특성에 대한 계통안전성 제어방식)

  • Lee, Geun-Joon;Hwang, Si-Dol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.29-35
    • /
    • 2005
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, HTS cable could be one of the countermeasure to enhance the transfer limit with its higher current capacity and lower impedance[1]. However, the quench characteristic makes not only HTS cable to loss its superconductivity, but also change the impedance of the transmission line and power system operating condition dramatically. This pheonominum threats HTS cable safety as well as power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method regarding conventional protection system was suggested.

A Study on Broadband PLC for Power IT (전력IT를 위한 광대역 전력선통신에 관한 연구)

  • Kim, Yeoun-Soo;Shin, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1599-1605
    • /
    • 2011
  • From now on, power line communication was made use of controling using 450 kHz narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. In this paper, analyze the possibility of moving picture transmission for adapting surveillance camera which is among of the application of PLC. To analyze characteristics of channel, estimate the noise and impedance of lab, office, home. In case of noise, there is no problem to communicate each other because of 20 ~ 50 dB gain. In case of impedance, average impedance is about 100 ohm, it satisfy standards of designing modem but because max and min values get out of expectation there are some problem to acquire fully capacity of modems. Its condition is the same as transmission of multimedia data. In this test as more packets, as more handling rate, in lab, for the case that transmit 1,518 byte as the speed of 6 Mbps handling rate is upto 100%, it means possibility of moving picture transmission as the 6 Mbps speed. For delayed time there is no relationship about transmitted packets. As a result, there is no problem about applying surveillance camera via the PLC. And more cameras can work within PLC for considering the number of transmitted frames.

Congestion and Loss cost for economic subject using Optimal Power Flow (최적 조류 계산을 이용한 경제주체별 혼잡 및 손실비용 산정)

  • Seo, Chul-Soo;Yoon, Gi-Gab;Park, Sang-Ho;Choy, Young-Do;Lee, Jae-Gul;Son, Hyun-Il;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.430-431
    • /
    • 2011
  • Recently the power system consists of the more complicated structure, due to increase of power demands. In this circumstance, the congestion and loss capacity in transmission line is also increased. Accordingly, the investment planning of transmission system is required to reduce the congestion and loss of the transmission line. In study of the planning of domestic and international transmission expansion, the reliability of transmission planning and minimizing Investment cost is focused. However, the study has not been performed systematically in economic aspects. Typically, the congestion and loss costs have been individually calculated. It is not consider the mutual relationship between the congestion cost and the loss cost. This paper proposes a method to compute concurrently the congestion and loss costs. This purpose is to calculate the more exact value for economic assessment of the power system operation.

  • PDF

A Study on the Spatial Composition of Health Facilities for the Elderly in Japan (일본 노인보건시설의 공간구성에 관한 연구)

  • Soh Jun-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.2 s.49
    • /
    • pp.142-152
    • /
    • 2005
  • It is estimated that the need to build health facilities for the elderly will grow in the near future as the Korean society is aging. Thus the study on the spatial composition of 22 facilities as well as on the cases of health facilities for the elderly in Japan, where public health and medicare for aged people are well taken care of, was conducted and the following are the results: 1. As of 2000, there was one facility for every 8,000 and 1,100 aged citizen under long-term care, and these facilities secured beds enough for $8\%$ of those who need long-term care. 2. The spatial composition was categorized into general living space, long-term care, management, provision, and home assistance, and housing was provided. Moreover, the space was divided according to their nature of use, the arrangement, the form of entrance into the building, moving line inside, the relationship with the health facilities and their characteristics are analyzed based on different users, managers, moving line including that of provision of food, the relationship between different spaces with different functions as well as on the relationship between locations of each space. 3. The total capacity, building area and actual area of the welfare facilities for the elderly are analyzed, and area per person, detailed area for each space, percentage of each living space for long-term care patients and characteristics of recuperation room are suggested.

Aging Analysis and Reconductoring of Overhead Conductors for Radial Distribution Systems Using Genetic Algorithm

  • Legha, Mahdi Mozaffari;Mohammadi, Mohammad
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2042-2048
    • /
    • 2014
  • In medium voltage electrical distribution networks, reforming the loss reduction is important, and in line with this, the issue of system engineering and use of proper equipment Expansion of distribution systems results in higher system losses and poor voltage regulation. Therefore, an efficient and effective distribution system has become more important. So, proper selection of conductors in the distribution system is crucial as it determines the current density and the resistance of the line. Evaluation of aging conductors for losses and costs imposed in addition to the careful planning of technical and economic networks can be identified in the network design. In this paper the use of imperialist competitive algorithm; genetic algorithm; is proposed to optimal branch conductor selection and reconstruction in radial distribution systems planning. The objective is to minimize the overall cost of annual energy losses and depreciation on the cost of conductors to improve productivity given the maximum current carrying capacity and acceptable voltage levels. Simulations are carried out on 69-bus radial distribution network using genetic algorithm approaches to show the accuracy as well as the efficiency of the proposed solution technique.

The Study on Correction of Protective Relaying Set Value for the Power Electric Network Paralleled with Wind Farm (풍력전단지의 계통 연계 운전에 따른 보호 계전기 설정치 정정에 관한 고찰)

  • Jang, Sung-Il;Choi, Don-Man;Choi, Jeong-Hwan;Kim, Kwang-Ho;Oh, Jong-Youl;Kim, Joo-Yearl
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.487-490
    • /
    • 2002
  • Wind farm paralleled with electric power network can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the power line with wind farm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator. Consequently, it is difficult to detect the fault happened in the distribution network connected with wind generator. This paper describes the influence of wind turbine generator on the protective relaying system for detecting the fault occurred in a power line network. Simulation results shows that the fault current depends on the fault impedance, location, and the capacity of wind farm and distribution network load.

  • PDF

Pressure Drop in a Circular Pipe of Waste Collection Piping System (쓰레기 관로 이송 시스템의 관로 압력강하 평가)

  • Jang, Choon-Man;Lee, Sang-Yun;Suh, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.55-60
    • /
    • 2007
  • This paper describes an evaluation method of pressure drop in a circular pipe of waste collection piping system. Accurate pressure drop in a piping system is very important to determine the capacity of turbo blower, which is one of the main elements in the system. Three-dimensional Navier-Stokes analysis is introduced to analyze the pressure drop in the piping system. Organic waste is selected and modeled using the result of site survey performed in an apartment area. Evaluation method of pressure drop used In the present numerical simulation is performed in the shortened pipe line prior to the calculation of the real system. Throughout the numerical simulation, pressure drop in a waste pipe is obtained and compared to the value determined by analytical method. The pressure drop obtained by numerical simulation has a good agreement with that of the analytic method. It is noted that present evaluation method is effective to determine a pressure drop in the piping system. Detailed flow characteristics inside the pipe line are also analyzed and discussed.

An Experimental Study on the Effects of EFV of LPG Engine on Automobiles Acceration Performance (LPG기관의 과류밸브가 가속성능에 미치는 영향에 관한 실험적 연구)

  • Jang Tae-Ik;Kim Chang-Hun;Kim Chul-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1072-1081
    • /
    • 2004
  • This paper is to investigate on the effects of the hole size of spring type EFV(excessive flow valve) for automobiles The analytical and experimental methods were employed to measure the discharge coefficient. choked flowrate and Pressure wave in a bombe, line and vaporizor The size of EFV was determined to meet the legally permitted limits with the capacity of engine displacement up to 2000cc, according to the obtained discharge coefficient. The Purpose of this paper is 1) to find causes of bad acceration performance in LPG engines 2) to find optimal design determination of spring coefficient and orifice hole size of excessive flow valve in LPG engine 3) to find pressure wave of bombe, line and vaporizer through expeimental verification. Experimental results indicated that increase of orifice size 0.5mm to 1mm be caused to increase discharge coefficient, and choked flow rate and decrease operation range of difference pressure wave.