• Title/Summary/Keyword: Line capacity

Search Result 1,075, Processing Time 0.03 seconds

Inelastic analysis of RC beam-column subassemblages under various loading histories

  • You, Young-Chan;Yi, Waon-Ho;Lee, Li-Hyung
    • Structural Engineering and Mechanics
    • /
    • v.7 no.1
    • /
    • pp.69-80
    • /
    • 1999
  • The purpose of this study is to propose an analytical model for the simulation of the hysteretic behavior of RC (reinforced concrete) beam-column subassemblages under various loading histories. The discrete line element with inelastic rotational springs is adopted to model the different locations of the plastic hinging zone. The hysteresis model can be adopted for a dynamic two-dimensional inelastic analysis of RC frame structures. From the analysis of test results it is found that the stiffness deterioration caused by inelastic loading can be simulated with a function of basic pinching coefficients, ductility ratio and yield strength ratio of members. A new strength degradation coefficient is proposed to simulate the inelastic behavior of members as a function of the transverse steel spacing and section aspect ratio. The energy dissipation capacities calculated using the proposed model show a good agreement with test results within errors of 27%.

A Study of Production System and Simulation Model for Womens Wear Manufacture (여성복 생산현황과 생산라인 설계를 위한 시뮬레이션 모델 개발)

  • 조진숙;박상희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.1
    • /
    • pp.103-114
    • /
    • 2001
  • In Korean clothing industry, most of the womens wear is manufactured by subcontractors. Because womens fashion is getting more rapidly changing, subcontractors production run of each orders is getting shorter too. Also the volume of each order is quite small compare to mens or childrens. So subcontractors are always in a hurry to adjust their production capacity to new order. Therefore they cannot afford to plan production line and allocate works efficiently enough to manufacture competitive products in terms of cost, lead time, as well as quality. The purpose of this study is to suggest a production planning model for womens apparel manufacture, which are relevant to the situation of Korean clothing industry.

  • PDF

Insulation Characteristic of Stator Winding for Large Capacity Hydorgenerator (대용량 수력발전기 고정자권선의 절연특성고찰)

  • Oh, Bong-Keun;Lee, Kwang-Ho;Kim, Hyun-Il;Byun, Doo-Gyoon;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2042-2043
    • /
    • 2008
  • 수력발전기의 운전중 신뢰성 및 장기 사용된 발전기의 경우 노후도 평가를 위한 지표로 고정자권선의 물리적 절연상태를 평가하는 방법이 일반적으로 이용되고 있다. 시험방법은 크게 부분방전 특성을 검출하는 운전중(On-line) 진단기법과 정지중(Off-line) 진단기법이 있다. 운전중 진단기법은 발전기의 정지없이 상시 상태를 감시할 수 있는 장점이 있으므로 활용도가 증가되고 있고 정지중 진단기법은 고정자권선 절연상태를 정밀하게 평가할 수 있는 잘 알려진 시험법으로 권선의 절연상태를 모니터링하여 운영자에게 고장징후를 알려주고, 예측보전이 가능하도록 도움을 주고 있다. 이 논문에서는 장기간 운영된 대용량 수력발전기의 정지중 절연진단기법(성극지수, 교류전류, 유전정접, 부분방전) 결과의 통계적 추이변화 고찰을 통하여 대용량 수력발전기 고정자 권선의 신뢰성평가를 실시하였다.

  • PDF

A study on the Development of Purge Burner for City Gas (도시가스용 퍼지 버너 개발에 관한 연구(II))

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.175-179
    • /
    • 2000
  • A combustion project was completed regarding the development of a high-flow-rate purge burner in cooperation with three city gas companies(Pusan, Taegu, Samchulli). The project, started in May 1991, aimed at purging the line-packed-gas safely and quickly before getting into gas pipe working or relocation. According to the results, the purging noise is less than 80dB due to silencer screen. multi-nozzle and outlet inserted tube employed. In addition, the developed burner shows an increased work efficiency of 40-50% more as compared to the performance of conventional purge equipments. The project result is regarded as the first high-flow-rate purge burner developed within Korea. contributing to shortening purge hours, safe field work and easiness of purge site selection.

  • PDF

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

Effect of Mo Addition of High-Strength Invar Alloy for Core of Transmission Line (송전선 강심용 고장도 인하합금의 Mo 첨가의 영향)

  • Kim, Bong-Seo;Yoo, Kyung-Jae;Kim, Byung-Geol;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.891-893
    • /
    • 1999
  • Invar alloys have characteristics with very low thermal expansion coefficient and low tensile strength. The mechanical properties of invar alloy have to being improved to apply for structural materials, especially for core of transmission line in electrical field. It is necessary low thermal expansion and high strength core material to transmit increased current capacity. In this paper, we investigated effect of Mo addition affected to thermal and mechanical properties and microstructure in Fe-Ni-Co ternary system.

  • PDF

Research about examination testimony of a witness of internal Onboard signal equipment (국내차상신호설비의 시험에 관한 연구)

  • Kim, You-Ho;Lee, Soo-Hwan;Kim, Young-Kyu;Baek, Jong-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1124-1125
    • /
    • 2006
  • Railroad business had repeated continuous development. Is developing old line improvement skill that technique aging of railroad and hangup of transport capacity decline are happened and minimum expense is spent. Developed skill and equipment are important and examination and by this are important. Therefore, examine skill and examination formality of equipment, examination item, examination kind etc.. developed serving speed elevation of old line in treatise.

  • PDF

A Feasibility Investigation of adoption for the Seat-type Express Electric railway on the Railroad in Metropolitan area - Focus on the double tracked Seoul-Chuncheon line - (광역철도 좌석형급행열차 도입 타당성에 관한 연구 - 경춘선 복선화구간 중심으로 -)

  • Park, Min-Kyu;Kim, Si-Gon
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1447-1457
    • /
    • 2008
  • The operation of the Seat-type Express Electric railway (SEE) has been watched for an alternative plan according to the increase of competition among the vehicle in metropolitan city. The purpose of this study was to examine a feasibility for the adoption of the SEE by analysis of various condition in the double tracked Souel-Chuncheon line. Fare estimate, station selection for SEE, managerial plan, demanding forecasting and analysis were performed to compute financial efficiency. The results showed financial validity on Revenue Cost Ratio (R/C), Financial Net Present Value (FNPV), Financial Internal Rate of Return (FIRR). This results indicate the evidence that SEE is a new means which is able to complement for finance, transportation capacity in metropolitan city.

  • PDF

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

3D FEA for the Cement Mortar Pouring type Paved Track (시멘트 모르터 충진형 포장궤도의 3차원 유한요소해석)

  • Lee Il-Wha;Lee Jin-Wook;Lee Su-Hyung;Lee Hyun-Suk
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.836-841
    • /
    • 2004
  • Recently, the development of the paved track is required as a Low-maintenance of conventional line. The main reason is that the line capacity and bearing of track are increased progressively. The most important factor of paved track is stability and applicability. To be based on this subject, Cement Mortar Pouring(CMP) paved track is developed. CMP paved track is a kind of ballast reinforced track using the pre packed concrete technique. The most important to design is characteristics of the structure. CMP slab's thickness is less than the conventional slab track and pouring layer is attached tie and roadbed directly. On this paper, to verify the basic structure of the CMP track, characteristics of the structure is investigated pouring layer, tie and interaction of the each layer using the 3D finite elment analysis.

  • PDF