• Title/Summary/Keyword: Line admittance

Search Result 38, Processing Time 0.022 seconds

A Study on the Efficient Extraction of Slot Admittance for the Design of a Non-Resonant Waveguide Edge Slot Array (비공진형 협벽 도파관 슬롯 배열 설계를 위한 효율적인 슬릇 어드미턴스 추출 방법에 관한 연구)

  • Park, Jong-Kuk;Han, Ki-Jin;Na, Hyung-Gi;Kim, Chan-Hong;Lee, Dong-Kook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1223-1232
    • /
    • 2008
  • In this paper, an analytic method is proposed to extract the reference slot admittance required for the design of a non-resonant waveguide edge slot array. A slot and two neighboring transmission line sections of the numerous alternately inclined slots with the identical inclination angle are modelled as a uniform lossy transmission line, and thus, the total ABCD matrix is easily calculated and compared with the simulated or measured one. From this procedure, the complex characteristic impedance and the complex propagation constant of the lossy transmission line are calculated and the normalized slot admittance is analytically obtained. In order to validate the proposed method, the admittance value of a reference slotted waveguide fabricated for designing the X-band edge slot array is extracted and it is compared with the one obtained by the other conventional method.

Back Fed Earth Fault Detection in Three Wire-Unigrounded Distribution-System By Zero Sequence Admittance (영상어드미턴스에 의한 직접접지 배전방식에서의 역가압 지락사고 검출)

  • Yoo, Myeong-Ho;Kim, Il-Dong;Han, Hong-Seok;Pak, Chul-Won
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.120-123
    • /
    • 1993
  • This paper presents the developing a new algorithm for detecting the Back fed Earth Fault in three wire-unigrounded distribution system by zero sequence admittance. So called "Backfed Earth Fault" of the electric power distribution line refers to a class of earth faults that the load-side line only is grounded, following after the distribution line broken into two parts, the source-side and the load-side. Because its mechanism differs from that of other earth faults, it is therefore, required to examine. This paper deals with the detailed software of the digital protective relay for Backfed earth fault. In order to prove that the proposed schemes is good, we performed off-line simulation using data from EMTP and ETSA(Electrcity Trust Of South Austrilia). It is shown that the suggested algorithm is never mal operated.

  • PDF

Radiation Admittance Calculation of the Rectangular Microstrip Antenna (구형 마이크로스트립 안테나의 복사어드미턴스 계산)

  • Hong, Jae-Pyo;Cho, Young-Ki;Son, Hyon
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.430-432
    • /
    • 1988
  • Radiation admittance of the rectangular microstrip antenna is calculated by using equivalent ${\pi}$-network parameters of the slit in the wall of the parallel plate waveguide filled with homogeneous dielectric. Using equivalent transmission line model, return loss is calculated and compared with experimental result. Calculated values for the return loss show good agreement with experimental values.

  • PDF

Improved Method for Calculating Radiation Admittance of a Rectangular Microstrip Patch Antenna (구형 마이크로스트립 안테나의 개선된 복사 어드미턴스 계산방법)

  • Hong, Jae-Pyo;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.35-40
    • /
    • 1989
  • In this paper, a new method which simultaneously gives the radiation conductance and susceptance of the rectangular microstrip patch antenna. This solution is derived from the load admittance of the equivalent ${\pi}-$network circuit of the slitted parallel-plate waveguide filled with homogeneous dielectric. Our theoretical results for the radiation admittance are compared with other theoretical results. Also, our theoretical return loss and resonant frequency which are calculated by use of the equivalent transmission line model are in fairly good agreement with the experimental results.

  • PDF

Power System State Estimation and Identification in Consideration of Line Switching (선로개폐상태를 포함하는 전력통계 상태추정및 동정)

  • 박영문;유석한
    • 전기의세계
    • /
    • v.28 no.3
    • /
    • pp.57-64
    • /
    • 1979
  • The static state estimation are divided into two groups; estimation and detection & identification. This paper centers on detection and identification algorithm. Especially, the identification of line errors is focused on and is performed by the extended W.L.S. algorithm with line swithching states. Here, line switching states mean the discrete values of line admittance which are influenced by unexpected line switching. The numerical results are obtained from the assumption that the noise vector is independent zero mean Gaussian random variables.

  • PDF

다층 유전체위의 다중 결합선로에 대한 유한차분법(FDTD)을 이용한 해석

  • 김윤석
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.155-163
    • /
    • 2000
  • A general characterization procedure based on the extraction of a 2n-port admittance matrix corresponding to n uniform coupled lines on the multi-layered substrate using the Finite-Difference Time-Domain (FDTD) technique is presented. The frequency-dependent normal mode parameters are obtained from the 2n-port admittance matrix, which in turn provides the frequency-dependent distributed inductance and capacitance matrices. To illustrate the technique, several practical coupled line structures on multi-layered substrate, including a three-line structure, have been simulated. It is shown that the FDTD based time domain characterization procedure is an excellent broadband simulation tool for the design of multiconductor coupled lines on multilayered PCBs as well as thick or thin hybrid structures.

  • PDF

Transmission Line Model for an Edge-Coupled Patch Antenna

  • Saksiri, Wiset;Chongcheawchamnan, Mitchai;Krairiksh, Monai
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.723-728
    • /
    • 2008
  • In this paper, a simple transmission line model for an edge-coupled patch antenna is presented. The coupled section is modeled with a lump network which represents the mutual admittance between patches and from patch to ground. Theoretical analysis of two edge-coupled patch antenna models are compared by simulation and experiment in antennas designed to operate at the 2 GHz band. The proposed model predicts the return loss of the antenna accurately.

  • PDF

An Overload Alleviation Algorithm by Line Switching (선로절환에 의한 과부화 해소 앨고리즘)

  • 박규홍;정재길
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.459-467
    • /
    • 1992
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads due to contingency without shedding loads in a power system. This method for relieving the line overloads by line switching is based on obtaining the kine outage distribution factors-the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of a line in a power system. There factors are made up of the elements of sparse bus reactance matrix and brach reactances. In this paper a fast algorithm and program is presented for obtaining only the required bus reactance elements which corresponds to a non-zero elements of bus admittance matrix, and elements of columns which correspond to two terminal buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on a 6-bus and the 30-bus test system.

  • PDF

An Impedance Transformer with Unequal Split Based on S-Parameter Conversion (S-파라미터 변환을 통한 비대칭 분배되는 임피던스 변환기)

  • Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.4
    • /
    • pp.361-366
    • /
    • 2016
  • This paper presents an arbitrary impedance transformer with unequal split, based on S- to admittance parameter conversion. When compared even/ odd- mode analysis, the parameter conversion design method constitutes a simple design method to include phase delay information and arbitrary port impedances and asymmetrical configurations. To validate this design method, we designed a 50 to $12.5{\Omega}$ impedance transformer with a 3:1 unequal power split, at an operating frequency of 1 GHz. To implement the proposed impedance transformer, the low impedance transmission lines of calculated result are fabricated by the transmission line connected shunt open stub. Good experimental performances were obtained, in full agreement with simulated results.

Analysis of Symmetric and Asymmetric Multiple Coupled Line on the Multi-layer Substrate (다층 기판위의 대칭 및 비대칭의 다중 결합선로에 대한 해석)

  • Kim, Yoonsuk;Kim, Minsu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.16-22
    • /
    • 2013
  • A general characterization procedure based on the extraction of a 2n-port admittance matrix corresponding to n uniform coupled lines on the multi-layered substrate using the Finite-Difference Time-Domain (FDTD) technique is presented. In this paper, the frequency-dependent normal mode parameters are obtained from the 2n-port admittance matrix to analyze multi-layered asymmetric coupled line structure, which in turn provides the frequency-dependent propagation constant, effective dielectric constant, and line-mode characteristic impedances. To illustrate the technique, several practical coupled line structures on multi-layered substrate have been simulated. Especially, embedded conductor structures have been simulated. Comparisons with Spectral Domain Method are given, and their results agree well. It is shown that the FDTD based time domain characterization procedure is an excellent broadband simulation tool for the design of multiconductor coupled lines on multilayered PCBs as well as thick or thin hybrid structures.