• 제목/요약/키워드: Line Test

검색결과 4,445건 처리시간 0.05초

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가 (Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line)

  • 김석수;최익순;박춘현;조이곤;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

아날로그 가입자 정합 회로 기능시험을 위한 무인 자동화 시스템 (Uumanned Automatic System for Function Test of Analog Subscriber Line Card)

  • 이성원;김영범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.432-437
    • /
    • 2002
  • DSPA311(Analog Subscriber Line Board Assembly) is offer the interface of between analog subscriber and TDX-100 exchange system. DSPA311 is belong ASI block, accommodate dial and MFC telephone subscriber of 32 channel, and voice signal designed for interface with TSW, and 2 and 4 wire loop impedance is 600 (ohm). DSPA311 is consist 4 channel daughter beard QSLM-10(Quad Subscriber Line Module-10) and perform BORSCHT and be possible A/U-law select and GAIN value control by data control of DSPA171(Device controller I). In this Paper, We described the function test program for the DSPA311 Board by using the HP3070CT combinational test system, and an unmanned automatic test system.

  • PDF

Analysis and Test results for the EOS(Electro Optical Subsystem) geometric mapping of the KOMPSAT2 Telescope

  • Jung Dae-Jun;Jang Hong-Sul;Lee Seung-Hoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.489-492
    • /
    • 2005
  • As a former level of MSC(Multi Spectral Camera) telescope of the KOMPSA T2satellite, the several performance tests of EOS(Electro Optical Subsystem) were performed in the EOS level. By these tests, not only the design requirement of payload can be verified but also the test result can be the important criterion to estimate the performance of payload in the launch and space orbit environment. The EOS Geometric Mapping test is to verify the accuracy of the alignment & assembly on the Subsystem of the MSC by measurement like these; LOS(Line of Sight), LOD(Line of Detector), Band to Band Registration, Optical Distortion and Reference Cube. This paper describes the test results and the analysis for the EOS Geometric Mapping.

  • PDF

765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구 (Environmental effects by corona discharge from a 765kV double circuit transmission line)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF

고속용 풀리형식 장력조정장치 개발 (A Development of Pulley-type Tensioning Device for a High Speed Railway)

  • 조용현;권삼영;박영;이기원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.723-730
    • /
    • 2006
  • In the electrical railway, the tension ascension of contact wire is essential to speed up of train and current collection performance of catenary largely depends on the tension. The tension variation rate of the tensioning device used in existing line limits within 5%, and the tension variation rate of the spring-type tensioning device installed at the section where tensioning length is short bounds within 15%. So it is urgent for us to localize it for high speed line, which the tension variation rate is limited within 3%. Therefore in this study, a pulley-type tensioning device for high speed line is developed. To verify the performance of developed device, a performance test, overload test and failure test is carried out under the code of the Kyung-Bu High Speed line. And it is secured durability performance through a fatigue test.

  • PDF

양양양수 온라인 무효전력 운전범위 시험과 과여자제한기(OEL) 동특성 시험 (On-line Tests of on the Yang-Yang Pumped Storage Plant for the Reactive Power Limits and the OEL Dynamics)

  • 김동준;문영환
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1343-1350
    • /
    • 2007
  • This paper describes the tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of a generation unit. The suggested test methods on reactive limit can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state unit operation condition. The on-line OEL test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to four Yang-Yang pumped storage units with 282 rated MVA each.

송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구 (A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay)

  • 서훈철;이홍학;김철환;이재욱;장병태;곽노홍;김호표;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF

인라인스케이터의 인라인스케이트 의복흥미(I) (In-line Skate Clothing Interest of In-line Skaters(I))

  • 김영란;유태순;조기여
    • 한국의류산업학회지
    • /
    • 제6권4호
    • /
    • pp.440-446
    • /
    • 2004
  • The purpose of this study was to classify the In-line skate clothing interest of in-line skaters according to in-line skate involvement. The questionnaire was administrated to 124 male, 96 female in-line skaters aged over 20 living in Daegu. Data were analyzed by using Frequency, Factor analysis, One-way analysis of variance, Duncan test, T-test, Correlation analysis. The results of this study can be summarized as follows ; The factor of in-line skate clothing interest of in-line skater were classified into 5 factor, expression orientation, performance enhancement, information dependence, anti deviation, individual assertion. The in-line skate clothing interest, men have interests in performance enhancement, women have interest in individual assertion. The more experience of in-line skate they have. the more interest in performance enhancement they want. High involvement in-line skater have high cloth interesting of sub-factors which are expression orientation, performance enhancement and individual assertion etc. As a result, we need more deliberate marketing strategies for the experience degree, involvement degree and women in-line skater then men.

고속 Line Center의 ATC 신뢰성 평가 (Reliability Evaluation of ATC for High-Speed Line Center)

  • 이승우;이화기;신동환
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.111-118
    • /
    • 2006
  • Recently, the reliability evaluation and analysis are applied far many industrial products which are required to guarantee in quality and efficiency. The purpose of this paper is to present some of reliability evaluation methodologies that are applicable to machine tools. Especially ATC (Automatic Tool Changer), which is a core component of line center, was chosen as the target of the reliability evaluation and analysis. The scope of research is reliability prediction, reliability test and evaluates their results. The results of reliability evaluation have shown the failure rates, MTBF (Mean Time Between Failure), reliability for those components of ATC and real tests reliability through the constructed reliability test-bed. It is expected that proposed methodologies would increase reliability for a high-speed line center.