• Title/Summary/Keyword: Line Standards

Search Result 540, Processing Time 0.033 seconds

A Study on the Unification of The Grounding System of SeoulMetro due to Ageing (서울메트로 접지시스템의 경년변화에 따른 개선 접지 기준)

  • Min Byung-Hoon;Kim Gyunl-Sig;Chung Young-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.394-400
    • /
    • 2006
  • Since Seoulmetro built the first line of electric railway at seoul 1974, the passengers of railway have been increased rapidly, and electric railway requires more electric power for the greater capacity of transport. It is important that we prevent the accidents related with the subway, because all systems of subway are constructed in artificial underground structure. Since the previous versions of the earth system were built to meet the old standards of the electric facility for the lightning, some accidents related with the DC earth fault are causing secondary damages to the electric equipments. So, the old grounding system must be improved, and new standards of grounding system are required. We compare the grounding systems of the domestic railway corporations and the accidents that are related with the grounding systems. And we give ideas to improve the grounding systems and present standards which are suitable to electric railway.

A review of test norm of Non-insulated AF Track Circuit (무절연 가청주파수(AF) 궤도회로 시험기준 고찰)

  • Chang, Seok-Gahk;Lee, Chang-Young;Kwon, Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1701-1706
    • /
    • 2007
  • Jointless AF(Audio Frequency) Track Circuit is more comfortable than exist joint track circuit. This electrical circuit's function is detection train on rail, and transmit information between wayside and vehicle. 'Korea Railroad Corporation' proposed for revision of the Korean railway standards(KRS SG 0038-06 R, 2006.5.16) "Non-insulated AF Track Circuit". This proposal equipment developed to extend use for station of National Railway exist line. According to test standards Korean railway safety law and its ordinances, which were committed to Korea Railroad Research Institute, the professional committee 'Railway facility sector II' have helded on January in 2007. In this investigation, the changed test norm will be review the difference of important function test standards of new version to conform effectivity and safety test procedure according to the KS A 1025.

  • PDF

Josephson Junction Array for Voltage Metrology: Microwave Enhancement by Coupled Self-Generations in Series Array (전압 측정표준용 조셉슨 접합 어레이: 직렬 어레이에서 상호 결합된 자체발진의 마이크로파 증진)

  • Kim K.-T.;Kim M.-S.;Chong Y.-W.
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • Coupling of non-linear oscillators have long been an interesting problem for physicists. The coupling phenomena have been frequently observed in Josephson junction series array, which have been used for Josephson voltage standard. Interestingly pronounced self-generation effect has been found during recent development of Josephson arrays for programmable Josephson voltage standard. But the coupling effect between the self-generations is not fully understood yet. We present harmonically approximated analytical solutions for coupled self-generations in the Josephson arrays, i.e., Superconductor-Insulator-Normal metal-Insulator-Superconductor (SINIS) array, externally shunted Superconductor-Insulator-Supercondctor (es-SIS) array, Superconductor-Normal metal-Superconductor (SNS) array. We find that the coupling between the self-generated Josephson oscillations through microwave transmission line plays critical role in microwave property of the Josephson array.

  • PDF

An Analysis of Derailment Safety in Conventional Line considering Current Railway Construction Regulations (현행 철도건설규칙을 고려한 기존선 구간에서의 탈선안전도 해석)

  • Kim, Young-Won;Eom, Beom-Gyu;Kang, Bu-Byoung;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1914-1921
    • /
    • 2011
  • When a railway vehicle passes through curves & transitions, the running speed must be improved by proposing the standards on the maximum running possibility speed of each section on conventional line (Dongdaegoo-Namsunghyun) considering derailment safety. In this paper, To improve the maximum running possibility speed of railway vehicle which passes through curves which have high risk of derailment, the track alignment conditions of conventional line (Dongdaegoo-Namsunghyun) that present transition curve length in current railway construction regulations are controlled. We presented elevation way about the section maximum running possibility speed in conventional line by analysis result.

  • PDF

Laser Welding Application in Car Body Manufacturing

  • Shin, H.O.;Chang, I.S.;Jung, C.H.
    • International Journal of Korean Welding Society
    • /
    • v.3 no.1
    • /
    • pp.2-7
    • /
    • 2003
  • Laser welding application for car body manufacturing has many advantages in the stiffness and the lightness of vehicle, the productivity of assembly line, and the degree of freedom in design. This presentation will express the innovation of car body manufacturing including parameter optimization, process modeling, and system integration. In this application the investment for systems was cut down dramatically by real time switching over the laser path between two welding stations. Points of technical discussion are as follows; optimization of parameters such as laser power, robot speed and trajectory, compact and useful design of jig & fixture to assure welding quality for 3 sheet-layer zinc-coated steel, system integration between 4㎾ Nd:YAG laser device and the other systems, on-line real time welding quality monitoring system, perfect safety standards for high power laser, minimization of consumption costs such as arc lamp, protective glass for optic, etc. This application was successfully launched mass production line in 2001. The laser-welded line of side panel consists of 122 stitches totally. And the length is about 2.4m.

  • PDF

Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System (전차선로 동적특성에 따른 설치상태 분석)

  • Park, Young;Lee, Kiwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1605-1609
    • /
    • 2016
  • The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 M모A 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2419-2422
    • /
    • 2010
  • The current marine internal communication systems are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. However, general vessel communication method have a weak point that must establish the extra private line. But, the power line communication has advantage over general vessel communication method as it uses AC220V/DC24V without changing line. Therefore, we will propose a new bridge based on the DC-PLC(power Line communication) technique which support the NMEA0183 protocol inside vessel network systems.

A Consistent Quality Bit Rate Control for the Line-Based Compression

  • Ham, Jung-Sik;Kim, Ho-Young;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.5
    • /
    • pp.310-318
    • /
    • 2016
  • Emerging technologies such as the Internet of Things (IoT) and the Advanced Driver Assistant System (ADAS) often have image transmission functions with tough constraints, like low power and/or low delay, which require that they adopt line-based, low memory compression methods instead of existing frame-based image compression standards. Bit rate control in the conventional frame-based compression systems requires a lot of hardware resources when the scope of handled data falls at the frame level. On the other hand, attempts to reduce the heavy hardware resource requirement by focusing on line-level processing yield uneven image quality through the frame. In this paper, we propose a bit rate control that maintains consistency in image quality through the frame and improves the legibility of text regions. To find the line characteristics, the proposed bit rate control tests each line for ease of compression and the existence of text. Experiments on the proposed bit rate control show peak signal-to-noise ratios (PSNRs) similar to those of conventional bit rate controls, but with the use of significantly fewer hardware resources.

High Efficiency and Small Size Switch Mode Line Transformer(SMLT) (고효율 및 소형 스위치모드 라인 트랜스포머)

  • Kim, Jin-Hong;Yang, Jung-Woo;Jang, Du-Hee;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.237-243
    • /
    • 2019
  • A high-efficiency and small-sized switched-mode line transformer (SMLT) is proposed in this study. The conventional structure of an adapter is composed of line transformer and rectifiers. This structure has a limit in miniaturizing due to low-frequency line transformer. Another structure is composed of power factor correction (PFC) and DC/DC converter. This structure has a limit in reducing volume due to two-stage structure. As the proposed SMLT is composed of an LLC resonant converter, a high-frequency transformer can be adopted to achieve isolation standards and size reduction. This proposed structure has different operation modes in accordance with line input voltage to overcome poor line regulation. In addition, the proposed SMLT is applied to the front of a conventional PFC converter, because the SMLT output voltage is restored to rectified sinusoidal wave by using a full-bridge rectifier in the secondary side. The design of the PFC converter is easy, because the SMLT output voltage is controlled as rectified sinusoidal wave. The validity of the proposed converter is proven through a 350 W prototype.

Resonant Frequency Estimation of Reradiation Interference at MF from Power Transmission Lines Based on Generalized Resonance Theory

  • Bo, Tang;Bin, Chen;Zhibin, Zhao;Zheng, Xiao;Shuang, Wang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1144-1153
    • /
    • 2015
  • The resonant mechanism of reradiation interference (RRI) over 1.7MHz from power transmission lines cannot be obtained from IEEE standards, which are based on researches of field intensity. Hence, the resonance is ignored in National Standards of protecting distance between UHV power lines and radio stations in China, which would result in an excessive redundancy of protecting distance. Therefore, based on the generalized resonance theory, we proposed the idea of applying model-based parameter estimation (MBPE) to estimate the generalized resonance frequency of electrically large scattering objects. We also deduced equation expressions of the generalized resonance frequency and its quality factor Q in a lossy open electromagnetic system, i.e. an antenna-transmission line system in this paper. Taking the frequency band studied by IEEE and the frequency band over 1.7 MHz as object, we established three models of the RRI from transmission lines, namely the simplified line model, the tower line model considering cross arms and the line-surface mixed model. With the models, we calculated the scattering field of sampling points with equal intervals using method of moments, and then inferred expressions of Padé rational function. After calculating the zero-pole points of the Padé rational function, we eventually got the estimation of the RRI’s generalized resonant frequency. Our case studies indicate that the proposed estimation method is effective for predicting the generalized resonant frequency of RRI in medium frequency (MF, 0.3~3 MHz) band over 1.7 MHz, which expands the frequency band studied by IEEE.