• Title/Summary/Keyword: Line Standards

Search Result 540, Processing Time 0.046 seconds

Development of Atmospheric Pressure Plasma Sources in KRISS

  • Tran, T.H.;You, S.J.;Kim, J.H.;Seong, D.J.;Jeong, J.R.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.151-151
    • /
    • 2011
  • Atmospheric-pressure plasmas are used in a variety of materials processes. The lifetime of most atmospheric-pressure plasma sources is limits by electrode erosion due to energetic ion bombardment. These drawbacks were solved recently by several microplasma sources based on microstrip structure, which are more efficient and less prone to perturbations than other microplasma sources. In this work, we propose microplasma sources based on strip line and microstrip line, developed for the generation of microplasmas even in atmospheric air and analyzes these systems with microwave field simulation via comparative study with two previous microwave sources (Microstrip Spit Ring Resonator (MSRR), Microstrip Structure Source (MSS)).

  • PDF

The Feasibility Study on a High-Temperature Application of the Magnetostrictive Transducer Employing a Thin Fe-Co Alloy Patch

  • Heo, Tae-Hoon;Park, Jae-Ha;Ahn, Bong-Young;Cho, Seung-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.3
    • /
    • pp.278-286
    • /
    • 2011
  • The on-line monitoring for the wall thinning in secondary system has been considered one of main issues for the safety of nuclear power plants. To establish the on-line monitoring technique for the pipe wall thinning, the development of the ultrasonic transducer working in high-temperature is very important. In this investigation, the magnetostrictive transducer is concerned for high temperature condition up to $300^{\circ}C$. The magnetostrictive transducer has many advantages such as high working temperature, durability, cost-effectiveness, and shear waves, most of all. A thin Fe-Co alloy patch whose Curie temperature is over $900^{\circ}C$ was employed as a ferromagnetic material for magnetostriction. Wave transduction experiments in various temperature were carried out and the effect of bias magnets was considered together with the dry coupling performance of the transducer. From experimental results, consequently, it was found that the magnetostrictive transducer works stable even in high temperature up to $300^{\circ}C$ and can be a promising method for the on-line monitoring of the wall thinning in nuclear power plants.

A Study on Specification of Hardware and Insulator for 400km/h Class High-speed Railway (400km/h급 고속철도용 금구 및 애자사양에 대한 고찰)

  • Cho, Ho-Ryung;Lee, Ki-Won;Kwon, Sam-Young;Cho, Young-Hyeon;Lee, Sang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1444-1452
    • /
    • 2011
  • At present, Kyungbu high-speed railway is operated with 300km/h, Honam high-speed railway is being constructed with 350km/h, and the development for the overhead contact line system is to be conducted for the next-generation high-speed railway with the speed of 400km/h. It is necessary to set up the specification and criteria for the key parts such as dropper, termination clamp and tension insulator for the 400km/h railway line. In this paper, the specification and the criteria for dropper, termination clamp and tension insulator has been reviewed and proposed in order to secure long-term reliability and stability under the maximum speed of 400km/h. Also, the specification, criteria and international standards for 300km/h class and 350km/h class railway line system and the international standards related with the insulators have been reviewed, compared and analysed.

  • PDF

Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation (낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준)

  • Woo, J.W.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

Development of On-line Content Evaluation Standards for Informatics Gifted Students (정보영재를 위한 온라인 콘텐츠 평가 준거 개발)

  • Kim, Yong;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.487-495
    • /
    • 2010
  • Online content evaluation standards were suggested in order to improve quality of education for informatics gifted students in this paper. This evaluation standards were developed by thinking and learning style and characteristics of gifted students which were presented in preceding research. The evaluation standards were reviewed through reliability analysis as well as analysis of the characteristics of items and validity analysis by experts of informatics gifted student education sector. In the result of analysis, reliability of items has been very reliable. Level of difficulty and discrimination about the characteristics of items has also shown satisfactory value. Developed the evaluation standards has 5 evaluation categories such as "talent development", "Interaction", and others. It also has 11 evaluation factors and 40 evaluation items. The online content evaluation standards can be helpful and useful in order to develop qualitative online contents and select online contents for informatics gifted student.

Measurement of Particles Generated from PECVD Process using ISPM (ISPM을 이용한 PECVD 공정 내 발생입자 측정 연구)

  • Kim, Dongbin;Mun, Jihun;Kim, HyeongU;Kang, Byung Soo;Yun, JuYoung;Kang, SangWoo;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.11 no.4
    • /
    • pp.93-98
    • /
    • 2015
  • Particles which generated from plasma enhanced chemical vapor deposition (PECVD) during thin film deposition process can affect to the process yield. By using light extinction method, ISPM can measure particles in the large-diameter pipe (${\leq}300mm$). In our research, in-situ particle monitor (ISPM) sensor was installed at the 300 mm diameter exhaust-line to count the particles in each size. In-house flange for mounting the transmitting and receiving parts of ISPM was carefully designed and installed at a certain point of exhaust line where no plasma light affect to the light extinction measurement. Measurement results of trend changes on particle count in each size can confirm that ISPM is suitable for real-time monitoring of vacuum process.

Saturated Absorption Spectroscopy of 13C2H2 in the Near Infrared Region

  • Moon, H. S.;Lee, W. K.;Suh, H. S.
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Using the external cavity spectroscopy method, we have observed the saturated absorption spectrum of the P(16) line of the v$_1$+v$_3$ band of $^{13}C$_2$H$_2$$. The frequency of a laser has been stabilized to the saturated absorption spectrum. The relative contrast of the saturation spectrum is about 7% with respect to the linear absorption and the linewidth is about 1.8 MHz. The frequency fluctuation of the stabilized LD is about $\pm$ 20 KHz for a sampling time of 100 ms.

Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band (마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구)

  • Yang, Seung-Hwan;Kim, Dong-Seok;Kim, Ki-Bok;Kim, Jong-Heon;Kang, Jin-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • In this paper, a non-contact microwave technique was presented to detect the surface crack of the metals. An open-ended coaxial cable line was used as a sensor at 11 GHz, and the reflection coefficients were measured by scanning along the metal surface including artificial surface cracks. A parameter, the K value which was defined as the difference between maximum and minimum reflection coefficients, was measured and used to estimate the crack depth. A linear relationship between the K value and crack depth was found. This study showed that non-contact detection of the surface cracks of metals is possible using the open-ended coaxial line sensor at X-band.