• Title/Summary/Keyword: Line Standards

Search Result 543, Processing Time 0.02 seconds

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

A Study on the Treatment of Uncertainty in Linear Regression Method for Chemical Analysis (회귀식 사용에 따른 화학 분석 과정의 불확도 처리 연구)

  • Woo, Jin-Chun;Suh, JungKee;Lim, MyungChul;Park, MinSu
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.185-190
    • /
    • 2003
  • We applied modified least square method (MLS) and ordinary least square method (OLS) to 1st order equation for the comparison of the uncertainties calculated by these methods. The uncertainty calculated by OLS covered statistically safe interval because it was over-estimated in many cases of measurement and concentration level. But, if the uncertainty of the concentration as a reference value was comparably large (about 5% of the relative standard deviation of random scattering from the regression line and about 7% of relative standard uncertainty of reference values), then uncertainty calculated by OLS was seriously under-estimated at high concentration level. It was revealed that the calculated uncertainty didn't cover statistically safe interval at the stated confidence level. It was found that the method, MLS, described in the previously article would be valid for this calculation of uncertainty.

A Study on Development of Certification Basis for VTOL UAS Based on Analysis of Certification Criteria for Fixed/Rotary Wing UAS and SC-VTOL (고정익/회전익 인증기준 및 수직이착륙 특수기술기준 분석 기반의 수직이착륙 무인항공기 인증기준 개발 방안)

  • Yoo, Minyoung;Kim, Suho;Oh, Yeonkyeong;Jin, Kyunghoon;Lee, Hwan;Kim, Woogyeom;Gong, Byeongho
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.5
    • /
    • pp.16-23
    • /
    • 2021
  • Domestic and foreign manufacturers are developing VTOL UASs in various shapes in line with demand for future technologies. UASs have been developed in a shape classified as fixed/rotary wing, and verified by appropriate certification standards. However, airworthiness certification of recent VTOL UASs is strict with the absence of VTOL-specific certification standards. In this paper, criteria applicable to VTOL UAS were presented through analysis of STANAG-4671 and STANAG-4702, which are certification standards for fixed/rotary wing UAS of the North Atlantic Treaty Organization (NATO) and the Special Condition for VTOL Aircraft (SC-VTOL) of European Aviation Safety Agency (EASA). For this, the categorization criteria of general/fixed-wing/VTOL characteristics were established for each standard item and utilized for analysis.

Colorectal cancer cells differentially impact migration and microRNA expression in endothelial cells

  • Do Yei Kim;Sang‑Soo Lee;Young‑Kyung Bae
    • Oncology Letters
    • /
    • v.18 no.6
    • /
    • pp.6361-6370
    • /
    • 2019
  • Angiogenesis is an essential step in cancer progression and metastasis. Changes in the microRNA (miRNA or miR) expression profiles of endothelial cells (ECs) elicited by cancer cells promote angiogenesis. Vascular endothelial growth factor (VEGF), a key pro-angiogenic factor, influences miRNA expression in ECs; however, the exact role that VEGF serves in miRNA regulation during angiogenesis is poorly defined. The present study aimed to demonstrate the differential angiogenic effects on human umbilical vein endothelial cells (HUVECs) of five different colorectal cancer (CRC) cell lines by in vitro HUVEC migration and angiogenesis assays in response to CRC-conditioned medium (CM). Among the tested CMs, LoVo was the most effective cell line in eliciting HUVEC angiogenic phenotypes, at least partially due to its high VEGF level. It was also observed that pro-angiogenesis-regulatory miRNAs (angio-miRNA) miR-296, miR-132, miR-105 and miR-200 were upregulated in the VEGF-rich LoVo CM compared with the VEGF-scarce SW620 CM. In addition, treatment with VEGF receptor 2 inhibitor downregulated the pro-angio-miRNAs, with the exception of miR-132, suggesting that VEGF, as well as additional signaling, is required for angio-miRNA expression. Quantitative analyses on pro-angio-miRNA target expression suggested that independent pathways may be involved in the regulation of their expression. Overall, the data from the present study indicated that multiple paracrine factors, including VEGF secreted by CRCs, effectively modulated angio-miRNA expression, thus impacting their target expression and the angiogenic phenotypes of HUVECs.

Assessment of capacity curves for transmission line towers under wind loading

  • Banik, S.S.;Hong, H.P.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.1-20
    • /
    • 2010
  • The recommended factored design wind load effects for overhead lattice transmission line towers by codes and standards are evaluated based on the applicable wind load factor, gust response factor and design wind speed. The current factors and design wind speed were developed considering linear elastic responses and selected notional target safety levels. However, information on the nonlinear inelastic responses of such towers under extreme dynamic wind loading, and on the structural capacity curves of the towers in relation to the design capacities, is lacking. The knowledge and assessment of the capacity curve, and its relation to the design strength, is important to evaluate the integrity and reliability of these towers. Such an assessment was performed in the present study, using a nonlinear static pushover (NSP) analysis and incremental dynamic analysis (IDA), both of which are commonly used in earthquake engineering. For the IDA, temporal and spatially varying wind speeds are simulated based on power spectral density and coherence functions. Numerical results show that the structural capacity curves of the tower determined from the NSP analysis depend on the load pattern, and that the curves determined from the nonlinear static pushover analysis are similar to those obtained from IDA.

Education On Demand System Based on e-Learning Standards (e-Learning 표준에 기반한 주문형 교육 시스템)

  • Hong, Gun Ho;Song, Ha Yoon
    • The Journal of Korean Association of Computer Education
    • /
    • v.6 no.3
    • /
    • pp.99-108
    • /
    • 2003
  • This paper indicates limitations of the existing VOD(Video on Demand)-based on-line education systems and presents the design and implementation of Education on Demand (EOD) system as an alternative. EOD system is based on meta information expressed in XML and component technology. Overall system consists of authoring tool. contents server, learning policy system and contents viewer. which are utilized throughout the learning contents life-cycle. EOD system enables automated contents management using meta information exchange methodology that is conformant to the SCORM meta data presentation scheme. In addition, integrated management of interaction and feedback information along with the learning policy system provides customized learning guide for each individual learner. With the development of EOD system, this paper discusses about advanced on-line education system which surpasses existing content-providing-only systems.

  • PDF

A Study on Broadband PLC for Power IT (전력IT를 위한 광대역 전력선통신에 관한 연구)

  • Kim, Yeoun-Soo;Shin, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1599-1605
    • /
    • 2011
  • From now on, power line communication was made use of controling using 450 kHz narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. In this paper, analyze the possibility of moving picture transmission for adapting surveillance camera which is among of the application of PLC. To analyze characteristics of channel, estimate the noise and impedance of lab, office, home. In case of noise, there is no problem to communicate each other because of 20 ~ 50 dB gain. In case of impedance, average impedance is about 100 ohm, it satisfy standards of designing modem but because max and min values get out of expectation there are some problem to acquire fully capacity of modems. Its condition is the same as transmission of multimedia data. In this test as more packets, as more handling rate, in lab, for the case that transmit 1,518 byte as the speed of 6 Mbps handling rate is upto 100%, it means possibility of moving picture transmission as the 6 Mbps speed. For delayed time there is no relationship about transmitted packets. As a result, there is no problem about applying surveillance camera via the PLC. And more cameras can work within PLC for considering the number of transmitted frames.

A Study on Description of IEC 61850 based Substation Topology for Implementing the Engineering Tool of Digital Substation (디지털변전소 엔지니어링 툴 구현을 위한 IEC 61850 국제규격 기반의 변전소 토폴로지 표현에 관한 연구)

  • Lee, Nam-Ho;An, Yong Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.23-32
    • /
    • 2015
  • In order to complete engineering works of the digital substation, Both Data transmission among a variety of IEDs and HMIs, and single line diagram of the substation might be done based on XML documents published in IEC 61850 international standards. This kind of XML based engineering process for the digital substation must be implemented not by manual written work but by the engineering tool using a computer. But most of the engineering tools do not support system based engineering works such as single line diagram of the substation but have only function to set IEDs as single device unit. Accordingly, this paper presents a new design method of the system based engineering description applicable to real IEC 61850 based substation through analyzing the current international standard and its sampled engineering file, and shows implementation of the engineering tool of the digital substation with the result of this study.

Placement Standard Research of Auxiliary Probes when Measuring Ground Impedance (접지임피던스 측정시 보조전극의 배치 기준 연구)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1984-1991
    • /
    • 2011
  • Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.

LASER WELDING APPLICATION IN CAR BODY MANUFACTURING

  • Shin, Hyun-Oh;Chang, In-Sung;Jung, Chang-Ho
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.181-186
    • /
    • 2002
  • Laser welding application for car body manufacturing has many advantages in the stiffness and the lightness of vehicle, the productivity of assembly line, and the degree of freedom in design. This presentation will express the innovation of car body manufacturing including parameter optimization, process modeling, and system integration. In this application the investment for systems was cut down dramatically by real time switching over the laser path between two welding stations. Points of technical discussion are as follows: optimization of parameters such as laser power, robot speed and trajectory, compact and useful design of jig & fixture to assure welding quality for 3 sheet-layer zinc-coated steel, system integration between 4kW Nd:YAG laser device and the other systems, on-line real time welding quality monitoring system, perfect safety standards for high power laser, minimization of consumption costs such as arc lamp, protective glass for optic, etc. Laser welding has found a place on Hyundai's production plant in conjunction with the startup of mass production of new sports car, and this production system is the result of a collaboration of its engineers. Outer side sheets are joined to inner side sheets by 122 stitch welds totally. And the length is about 2.4meter.

  • PDF