• Title/Summary/Keyword: Limits

Search Result 7,100, Processing Time 0.036 seconds

Multi Area Economic Dispatch using Secant Method

  • Sudhakar, A.V.V.;Chandram, Karri;Jayalaxmi, A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.744-751
    • /
    • 2013
  • In this paper, Secant method is proposed to solve multi area economic dispatch (MAED) problem. Generator limits of all generators in each area are calculated at given area power demands plus export (or import) using secant method and the generator limits of all generators are modified as modified generator limits. Central economic dispatch (CED) problem is used to determine the output powers of all generators. Here, Secant method is applied to solve the CED problem. The proposed approach has been tested on two-area (two generators in each area) system and four-area (four generators in each area) system. It is observed from various cases that the proposed approach provides optimally best solution in terms of cost with tie line loss with less computational burden.

Prediction of Upper Explosion Limits(UEL) by Measurement of Upper Flash Points for n-Alkanes and Aromatic Compounds (노말알칸류와 방향족탄화수소류의 상부인화점 측정에 의한 폭발상한계의 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.59-64
    • /
    • 2011
  • Explosion limit and flash point are the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, in order to predict upper explosion limits(UELs), the upper flash point of n-alkanes and aromatic compounds were measured under the VLE(vapor-liquid equilibrium) state by using Setaflash closed cup tester(ASTM D3278). The UELs calculated by Antoine equation and chemical stoichiometric coefficient tusing the experimental upper flash point were compared with the several reported UELs. From the given results, using the proposed experimental and predicted method, it is possible to research the upper explosion limits of the other flammable substances.

Numerical simulation of the effects of localized cladding oxidation on LWR fuel rod design limits using a SLICE-DO model of the FALCON code

  • Khvostov, Grigori
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.135-147
    • /
    • 2020
  • A methodology for evaluation of mechanical and thermal effects of localized non-axisymmetric oxidation in zircaloy claddings on LWR fuel reliability is proposed. To this end, the basic capabilities of the FALCON fuel behaviour code are used. Examples of methodology application to adjustment of selected operational limits for modern BWR fuel rods, to capture effects of the excess local oxidation, are presented. Specifically, the limiting rod internal pressure for the onset of cladding lift-off is reduced, depending on initial excess oxidation spot sizes. Also, the power limits for Anticipated Operational Occurrences are adjusted, to preclude fuel melting and cladding failure due to PCMI and PCI-SCC in the affected fuel rods.

Effect of Salinity on Survival and Metabolism of ark shell, Tegillarca granosa (꼬막, Tegillarca granosa의 생존과 대사에 미치는 염분의 영향)

  • Moon, Tae-Seok;Shin, Yun-Kyung
    • The Korean Journal of Malacology
    • /
    • v.26 no.3
    • /
    • pp.171-177
    • /
    • 2010
  • We examined physiological responses related to the survival, oxygen consumption and filtration rate of the blood cockle, Tegillaarca granosa as a result of salinity changes. The 44-day $LS_{50}$ (median lethal salinity) at $10^{\circ}C$ for adult and juvenile was 15.8 (confidence limits 13.5-18.2 psu) and 16.2 (confidence limits 14.1-18.4 psu) psu respectively, whereas the 11-day $LS_{50}$ at $25^{\circ}C$ for adult and juvenile was 16.8 psu (confidence limits 12.9-21.2 psu) and 22.4 (confidence limits 20.5-24.7 psu) psu respictively. In conditions of decreasing salinity, Oxygen consumption and filtration rates decreased or varied irregularly as salinity decreased. The results of this study could prove important in investigating causes of mass mortality and managing shellfish aquaculture farms.

Calculation of Combustion Stability Limits Using Linear Stability Analysis in Liquid Rocket Engines (액체 로켓엔진에서 선형 연소 불안정 해석을 이용한 연소 안정한계 곡선 계산)

  • Sohn, Chae-Hoon;Moon, Yoon-Wan;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.93-101
    • /
    • 2004
  • A method to calculate stability limits is investigated to predict the characteristics of high-frequency combustion instability in liquid-propellant rocket engine. It is based on the theory of linear stability analysis proposed in previous works and useful to predict combustion stability at the beginning stage of engine development. The system of equations governing reactive flow in combustor has the simplified and linearized forms. The overall equation expressing stability limits is adopted. The procedures to evaluate quantitatively each term included in the equation are proposed. The thermo-chemical properties and flow variables required in the evaluation can be obtained from calculation of thermodynamic equilibrium, CFD results, and experimental test data. Based on the existent data, stability limits are calculated with actual rocket engine (KSR-III rocket engine). The present calculations show the reasonable stability limits in a quantitative manner and the stability characteristics of the engine are discussed. The prediction from linear stability analysis could be serve as the first approximation to the true prediction.

Seismic Fragility Analysis of Reinforced Concrete Bridge Piers According to Damage State (철근콘크리트 교량 교각의 손상상태에 따른 지진취약도 해석)

  • Jeon, Jeong Moon;Shin, Jae Kwan;Shim, Jae Yeob;Lee, Do Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1695-1705
    • /
    • 2014
  • In the present study, a total of 275 tested specimens (149 of non-seismically designed and 126 of seismically designed) for reinforced concrete bridge piers with circular section have been investigated in order to suggest drift limits probabilistically according to damage states in seismic fragility analysis. Thus, quantitative damage states of the piers have been evaluated depending on details of the piers. Nonlinear time-history analyses have been conducted for a damaged bridge in terms of using the suggested drift limits. Then, seismic fragility analysis for a reinforced concrete bridge structure has been conducted using both suggested and existing drift limits. Comparative analyses have revealed that median values by the suggested limits is smaller than those by the existing limits. This implies that seismic performance of the structure can be overestimated when the existing limits are used.

The Effects on the Atterberg Limits of Clays with Heat Treatment (열처리에 따른 점토의 애터버그 한계 영향)

  • Min, Tuk-Ki;Hwang, Kwang-Mo;Lee, Sung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.29-34
    • /
    • 2007
  • This study examines the effects of heat treatment under laboratory conditions for mixtures of two types of clay (kaolinite and montmorillonite). Clay samples were burned with different temperatures ranging from $100^{\circ}C\;to\;500^{\circ}C$. The Atterberg limits such as liquid and plastic limits were influenced with heat treatment. According to the experimental results, the liquid limits slightly decreased between $100^{\circ}C\;to\;300^{\circ}C$, whereas rapid decreases were observed after $300^{\circ}C$. The plastic limits did not show noticeable differences in the interval $100^{\circ}C\;to\;400^{\circ}C$. But the clay samples showed non plastic behavior at $500^{\circ}C$. The amount of NaCl was getting decreased with temperature. It also revealed that the pH values were also influenced with heat treatment, and the cation exchange capacity (C.E.C) values decreased with temperature.

Comparison of Occupational Exposure Limits in Six Agencies for Hazardous Substances Related Workers' Periodic Health Examination in South Korea (우리나라 특수건강진단 대상물질에 대한 6개 기관의 직업적 노출 기준 비교)

  • Lee, Sangyoon;Suh, Chun-Hui;Kim, Se-Yeong;Ye, Byeong Jin;Sul, Jingon;Son, Jun-Seok;Yoon, Jongwan;Hong, Sukwoo;Ryu, Ji Young;Kim, Dae-Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.148-155
    • /
    • 2013
  • Objectives: This study was performed in order to compare the average levels and similarity of occupational exposure limits in South Korea, the U.S., the E.U., Germany, Japan and Finland. Methods: In this study, occupational exposure limits (OELs) for one hundred and seventy seven hazardous substances which are managed in the workplace by the Occupational Safety and Health Act in South Korea were matched with those of other countries. The units for the exposure limits of the same substance (identical CAS number) were unified and the exposure limits in each country were compared with threshold limit values (TLVs) of the American Conference of Governmental Industrial Hygienists (ACGIH) using a geometric mean method. Geometric similarity was calculated to assess the association by each country. Results: The exposure limits according to ACGIH TLVs in South Korea, the E.U., Germany, Japan, and Finland were 148, 37, 76, 90, and 110, respectively. When using TLVs of ACGIH as a standard, the geometric mean ratios of Germany, Finland, the E.U., South Korea, and Japan were 0.79, 0.80, 0.82, 1.19, and 1.27, respectively. Geometric similarity with TLVs of ACGIH was highest in South Korea (0.75) followed by Japan (0.56), the E.U. (0.52), Finland (0.50), and Germany (0.46). Conclusions: Through the comparison of levels of OELs and similarities among South Korea, the U.S., the E.U., Germany, Japan, and Finland, we could better understand the characteristics of occupational exposure limits by country.

Prediction of Retention Indices of Various Compounds in Gas-Liquid Chromatography (기체-액체 크로마토그래피에서 화합물의 머무름 지표의 예측에 관한 연구)

  • Cha, Gi Won;Lee, Deok Jae
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.108-121
    • /
    • 1994
  • The retention indices of branched-chain alkane, benzene ring, alcohol, amine, ketone, aldehyde and cyclic compounds were measured at 150, 180 and $210^{\circ}C$ on OV-1701 and OV-1 capillary columns. The group retention factors (GRF) of the substituents and the st` ructure retention factors (SRF) of the molecular structure change are derived from the retention indices of reference compounds and series of homologues. The $GRF_f$ equation of `f'th substituent is $GRF_f\;=\;I_{obs}-(100Z + \sum\limits_{i{\neq}f}GRF_i$ + {\sum}$SRF_i$)and the SRFf equation of `f'th molecular structure group is $SRF_f\;=\;I_{obs}-(100Z + {\sum}GRFi + \sum\limits_{i{\neq}f}SRF_i$). The predicted retention indices for those compound were in agreement, within the error of $\pm2$ and $\pm3%$, with the observed values that were obtained using the OV-1701 and OV-1 capillary column, respectively. The $\Delta$ xi of the substituents and $\Delta$ yi of the molecular structure change according to temperature change are derived from the $\Delta'/^{\circ}C$ of reference compounds and series of homologues. The $\Delta$ xi equation of the `f'th substituent is ${\Delta}x_f = {$\Delta}'/^{\circ}C+ \sum\limits_{i{\neq}f}\Delta$ xi + {\sum}{\Delta}yi\;and\;{\Delta}yi$ equation of the `f'th molecular structure group is ${\Delta}y_f$ = {\Delta}'/^{\circ}C+{\sum}{\Delta}xi +\sum\limits_{i{\neq}f}{\Delta}yi$. The predicted $\Delta'/^{\circ}C$ for these compounds were in agreement, within the error of ${\pm}18%$ and 17%, with the observed values that were obtained using the OV-1701 and OV-1 capillary column, respectively.

  • PDF