• 제목/요약/키워드: Limiting Efficiency

검색결과 259건 처리시간 0.023초

리튬이차전지용 Polyacenic Semiconductor Material의 전기화학적 특성

  • 박수길;박종은;;이주성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 1998
  • During the past decade, substantial research effort has been directed into the development of rechargeable lithium batteries. Although some improvements in cycle life and efficiency have been achieved, the reversibility of the lithium electrode remains as a significant problem in aprotic solvent based electrolyte. The major problems limiting cycle life are short circuits resulting from growth of lithium dendrites, and macroscopic shape changes during the recharge process. As an anode material of lithium rechargeable battery, amorphous carbon materials have been studied extensively because of their high electrochemical performance. The polyacene materials prepared from phenol refine at relatively low temperature(550∼750$^{\circ}C$) show a highly Li-doped state up C$_2$Li state without liberation of Li cluster. So it has largely layered distance 4${\AA}$. The Li storage mechanism as well as the large hysterisis observed in the voltage-capacity profile of the amorphous carbone materials are still the subjects of controversy. We prepared each polyacene material various temperature and investigated electrochemical property. The mole ratio of [H]/[C] is 0.027∼0.015 range.

  • PDF

확률론적 조류계산을 이용한 송전 신뢰도 여유 계산 (Calculate Transmission Reliability Margin using Probabilistic Load Flow)

  • 신동준;김진오;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2003
  • As a definition of NERC, Available Transfer Capability(ATC) is a measure of the transfer capability remaining in the physical transmission network for the future commercial activity. To calculate ATC, accurate and defensible TTC, CBM and TRM should be calculated in advance. In this paper, we propose a method to quantify TRM using probabilistic load flow based on the method of moment. Generation output, bus voltages, loads, and line outages are considered as complex random variables (CRV) to take into account for uncertainties related to the transmission network conditions. Probability Density Function (PDF) of line flow at the most limiting line is used to quantify TRM with the desired probabilistic margin. Suggested method is compared with the results from conventional CPF method and verified using 24 bus MRTS, and the suggested method based on PLF shows efficiency and flexibility for the quantification of TRM compared with the conventional method.

  • PDF

A Modified Single Sampling Plan for the Inspection of Attribute Quality Characteristics

  • Subramani, J.;Balamurali, S.
    • Industrial Engineering and Management Systems
    • /
    • 제15권1호
    • /
    • pp.41-48
    • /
    • 2016
  • In this manuscript, a modified single sampling plan is proposed for the inspection of products in which the nonconforming items can be classified in to two categories namely critical and non-critical; and explained with the help of industrial example. The operating procedure of this plan is also proposed and the performance measures such as the probability of acceptance, average sample number, average total inspection and average out going quality are also derived. The optimal parameters are determined which will have minimum sample size. The efficiency of the proposed plan is also discussed over the conventional single sampling plan. The extensive tables for selecting a modified single sampling plan based on AQL and LQL are provided for both Binomial and Poisson distributions and explained with the help of industrial data.

이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발 (Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System)

  • 정병창;김희중;정용호;전영수;곽노홍;송승호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

Span limit and parametric analysis of cable-stayed bridges

  • Zhao, Xinwei;Xiao, Rucheng;Sun, Bin
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.271-282
    • /
    • 2019
  • The span record of cable-stayed bridges has exceeded 1,000 m, which makes research on the maximum possible span length of cable-stayed bridges an important topic in the engineering community. In this paper, span limit is discussed from two perspectives: the theoretical span limit determined by the strength-to-density ratio of the cable and girder, and the engineering span limit, which depends not only on the strength-to-density ratio of materials but also on the actual loading conditions. Closed form equations of both theoretical and engineering span limits of cable-stayed bridges determined by the cable and girder are derived and a detailed parametric analysis is conducted to assess the engineering span limit under current technical conditions. The results show that the engineering span limit of cable-stayed bridges is about 2,200 m based on materials used available today. The girder is the critical member restricting further increase in the span length; its compressive stress is the limiting factor. Approaches to increasing the engineering span limit are also presented based on the analysis results.

Effects of Dietary Levels of Glycine, Threonine and Protein on Threonine Efficiency and Threonine Dehydrogenase Activity in Hepatic Mitochondria of Chicks

  • Lee, C.W.;Cho, I.J.;Lee, Y.J.;Son, Y.S.;Kwak, I.;Ahn, Y.T.;Kim, S.C.;An, W.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권1호
    • /
    • pp.69-76
    • /
    • 2014
  • This study was carried out to evaluate the relationship between threonine (Thr) efficiency and Thr dehydrogenase (TDG) activity as an indicator of Thr oxidation on chicks fed with levels of diets (CP [17.5% and 21.5%] and Thr [3.8 and 4.7 g/100 g CP]; glycine [Gly][0.64% and 0.98%] and true digestible Thr [dThr] [0.45% and 0.60%]). Calculation of the Thr efficiency was based on N-balance data and an exponential N-utilization model, and TDG activity was determined as accumulation of aminoacetone and Gly during incubation of hepatic mitochondria. This study found that in the liver of chicks who received a diet containing up to 0.79% Thr (4.7 g Thr/100 g of CP) in the 17.5% CP diet, no significant (p>0.05) effect on TDG activity was observed. However, significantly (p = 0.014) increased TDG activity was observed with a diet containing 21.5% CP (4.7 g Thr/100 g of CP) and the efficiency of Thr utilization showed a significant (p = 0.001) decrease, indicating the end of the Thr limiting range. No significant (p>0.05) effect on the total TDG activity and accumulation of Gly was observed with addition of Gly to a diet containing 0.45% dThr. In addition, addition of Gly to a diet containing 0.60% dThr also did not result in a change in accumulation of Gly. Due to an increase in accumulation of aminoacetone, an elevated effect on total TDG activity was also observed. No significant (p>0.05) reduction in the efficiency of Thr utilization was observed after addition of Gly at the level of 0.45% dThr. However, significantly (p<0.001) reduced efficiency of Thr utilization was observed after addition of Gly at the level of 0.60% dThr. Collectively, we found that TDG was stimulated not only by addition of Thr and protein to the diet, but also by addition of Gly, and efficiency of Thr utilization was favorably affected by addition of Gly at the level near to the optimal Thr concentration. In addition, no metabolic requirement of Gly through the TDG pathway was observed with almost the same accumulation of Gly and a slight increase in TDG activity by addition of Gly. Thus, our findings suggest that determination of TDG activity and parameter of efficiency of Thr utilization may be useful for evaluation of dietary Thr level.

DEA와 토빗회귀 모형을 이용한 전문건설기업 효율성 결정요인 분석 (Determinants of Efficiency of Specialty Construction Companies Using DEA and Tobit Regression Models)

  • 정대운;손영훈;김경래
    • 한국건설관리학회논문집
    • /
    • 제25권2호
    • /
    • pp.45-55
    • /
    • 2024
  • 본 연구는 DEA 모형과 Tobit 모형을 이용하여 전문건설기업의 업종별 효율성과 효율성 결정요인을 분석하였다. 분석대상은 2022년도를 기준으로 한 394개 전문건설기업이다. 먼저 효율성 분석결과, 지반조성‧포장공사업의 효율성이 주요 7개 업종 중 가장 낮게 나타나 효율성 향상을 위한 전략 마련이 가장 시급한 상황이다. 또한 철근‧콘크리트공사업과 지반조성‧포장공사업, 구조물해체‧비계공사업은 매출액 효율성 대비 영업이익 효율성이 낮아 투입요소의 관리전략이 우선적으로 마련되어야 한다. 다음으로 12개 기업특성을 독립변수로 한 효율성 결정요인의 분석결과, 전문건설기업은 전반적으로 인건비 상승에 따른 효율성 감소가 가장 큰 문제였다. 또한 건설기업의 대출규제가 심각한 상황에서 부채비율이 효율성에 긍정적 효과를 가지는 것으로 나타났다. 마지막으로 업종별 효율성 결정요인을 비교한 결과, 업종별 결정요인과 미치는 영향의 차이가 발생하였다. 기업규모는 업종별로 다른 영향을 미쳤고, 보유업종수나 신용점수, 총자본회전율은 일부 업종에만 영향을 미쳤다. 본 연구는 전문건설기업의 효율성 향상을 위한 요인을 정량적으로 분석하였다는 점에서 기존 연구의 진일보한 결과를 제시하였다. 그러나 외부감사 대상인 전문건설기업만을 분석대상으로 한정한 점과 업종별 분석대상 기업수가 부족한 점, 업종별로 동일한 범주에서 상대적 효율성을 분석했다는 점 등의 한계점을 갖는다.

Analysis and Reduction of Crosstalk on Coupled Microstrip tines by Using FDTD Method

  • Pichaya Supanakoon;Monchai Chamchoy;Panarat Rawiwan;Prakit Tangtisanon;Sathaporn Promwong;Teerasilpa Dumwipata;Takada, Jun-ichi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.523-526
    • /
    • 2002
  • The crosstalk among coupled microstrip lines is the major limiting factors of signal qualities in the high-speed digital and communication equipment. In this paper, a three-dimensional finite difference time domain (FDTD) method is applied to analyze the crosstalk between the coupled microstrip lines. The proposed structures of the coupled microstrip lines are investigated to reduce the coupling in a simple way by modifying their ground plane with an optimum gap. The examples of these structures with the different sizes of the gaps on their ground plane are studied. These structures are considered as the four-port network to evaluate transmission efficiency, near- and far-end crosstalk. Gaussian pulse is excited to evaluate the frequency characteristics from dc to 30 ㎓. The transmission efficiency, near- and far-end crosstalk of each structure of the coupled microstrip lines are demonstrated. The numerical results of this study show that the majority of crosstalk is the far-end crosstalk. The usage of the optimum gap on the ground plane can reduce the far-end crosstalk of the coupled microstrip lines while the transmission efficiency is nearly equal.

  • PDF

Fast CU Encoding Schemes Based on Merge Mode and Motion Estimation for HEVC Inter Prediction

  • Wu, Jinfu;Guo, Baolong;Hou, Jie;Yan, Yunyi;Jiang, Jie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권3호
    • /
    • pp.1195-1211
    • /
    • 2016
  • The emerging video coding standard High Efficiency Video Coding (HEVC) has shown almost 40% bit-rate reduction over the state-of-the-art Advanced Video Coding (AVC) standard but at about 40% computational complexity overhead. The main reason for HEVC computational complexity is the inter prediction that accounts for 60%-70% of the whole encoding time. In this paper, we propose several fast coding unit (CU) encoding schemes based on the Merge mode and motion estimation information to reduce the computational complexity caused by the HEVC inter prediction. Firstly, an early Merge mode decision method based on motion estimation (EMD) is proposed for each CU size. Then, a Merge mode based early termination method (MET) is developed to determine the CU size at an early stage. To provide a better balance between computational complexity and coding efficiency, several fast CU encoding schemes are surveyed according to the rate-distortion-complexity characteristics of EMD and MET methods as a function of CU sizes. These fast CU encoding schemes can be seamlessly incorporated in the existing control structures of the HEVC encoder without limiting its potential parallelization and hardware acceleration. Experimental results demonstrate that the proposed schemes achieve 19%-46% computational complexity reduction over the HEVC test model reference software, HM 16.4, at a cost of 0.2%-2.4% bit-rate increases under the random access coding configuration. The respective values under the low-delay B coding configuration are 17%-43% and 0.1%-1.2%.

원심분리 장치를 이용한 퇴적물 처리 (Sediment Treatment by a Centrifugal Device)

  • 이영식;조영민;오종민
    • 생태와환경
    • /
    • 제34권4호통권96호
    • /
    • pp.342-348
    • /
    • 2001
  • 본 연구는 호소내 오염된 퇴적물 처리를 위한 분리 및 농축을 위한 전처리 장치로서 hydrocyclone의 이용 가능성을 평가하는 실험이다. 외국의 선행 연구자인 Rietema의 표준 규격을 참고하여 제작된 Hydrocyclone을 이용하여 분리 및 농축 실험과 유입 및 배출 시료의 물리화학적 특성을 조사하였다. 실험결과 Hydrocyclone의 장치특성 실험에서 분리 및 농축에 가장 큰 영향요소는 몸통직경이며, 유입속도, 유입시료의 농도에 영향을 받는 것으로 조사되었다. 분리 및 농축에 필요한 한계 유입속도는 1.5 m/s로 조사되었으며, Cyclone의 몸통 직경이 작고, 유입 속도가 빠르며, 유입되는 시료의 농도가 낮을수록 분리 및 농축 효율이 높은 것으로 조사되었다. 재활용 가능성 평가를 위한 오염도 평가 결과 입자의 입경이 작을수록 오염도가 높은 것으로 조사되었으며, 분리 처리 결과 현저하게 높은 유기물 제거율을 보였다.

  • PDF