• Title/Summary/Keyword: Limit strength

Search Result 1,264, Processing Time 0.025 seconds

A Proposal of Flow Limit for Soils at Zero Undrained Shear Strength (흙의 비배수전단강도가 0이 되는 함수비인 흐름한계의 제안)

  • Park, Sung-Sik;Nong, Zhenzhen
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.73-84
    • /
    • 2013
  • When a slope failure or a debris flow occurs, a shear strength on failure plane becomes nearly zero and soil begins to flow like a non-cohesive liquid. A consistency of cohesive soils changes as a water content increases. Even a cohesive soil existing at liquid limit state has a small amount of shear strength. In this study, a water content, at which a shear strength of cohesive soils is zero and then cohesive soils will start to flow, was proposed. Three types of clays (kaolinite, bentonite and kaolinite (50%)+bentonite (50%)) were mixed with three different solutions (distilled water, sea water and microbial solution) at liquid limit state and then their water contents were increased step by step. Then, their undrained shear strength was measured using a portable vane shear device called Torvane. The ranges of undrained shear strength at liquid and plastic limits are 3.6-9.2 kPa and 24-45 kPa, respectively. On the other hand, the water content that corresponds to the value of the undrained shear strength changing most rapidly is called flow water content. The flow limit refers to the water content when undrained shear strength of cohesive soils is zero. In order to investigate the relationship between liquid limit and flow limit, the cohesive index was defined as a value of the difference between flow limit and liquid limit. The new plasticity index was defined as the value of difference between flow limit and plastic limit. The new liquidity index was also defined using flow limit. The values of flow limit are 1.5-2 times higher than those of liquid limit. At the same time, the values of new plasticity index are 2-5.5 times higher than those of original plasticity index.

Slenderness limit for SSTT-confined HSC column

  • Khun, Ma Chau;Awang, Abdullah Zawawi;Omar, Wahid
    • Structural Engineering and Mechanics
    • /
    • v.50 no.2
    • /
    • pp.201-214
    • /
    • 2014
  • Due to the confinement effects, Steel-Straps Tensioning Technique (SSTT) can significantly enhance the strength and ductility of high-strength concrete (HSC) members (Moghaddam et al. 2008). However, the enhancement especially in strength may result in slender member and more susceptible to instability (Jiang and Teng 2012a). This instability is particularly significant in HSC member as it inherent the brittle nature of the material (Galano et al. 2008). The current slenderness limit expression used in the design is mainly derived from the experiment and analysis results based on Normal strength concrete (NSC) column and therefore the direct application of these slenderness limit expressions to the HSC column is being questioned. Besides, a particular slenderness limit for the SSTT-confined HSC column which incorporated the pre-tensioned force and multilayers effects is not yet available. Hence, an analytical study was carried out in the view of developing a simple equation in order to determine the slenderness limit for HSC column confined with SSTT. Based on the analytical results, it was concluded that the existing slenderness limit expressions used in the design are appropriate for neither HSC columns nor SSTT-confined HSC columns. In this paper, a slenderness limit expression which has incorporated the SSTT-confinement effects is proposed. The proposed expression can also be applied to unconfined HSC columns.

Span limit and parametric analysis of cable-stayed bridges

  • Zhao, Xinwei;Xiao, Rucheng;Sun, Bin
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.271-282
    • /
    • 2019
  • The span record of cable-stayed bridges has exceeded 1,000 m, which makes research on the maximum possible span length of cable-stayed bridges an important topic in the engineering community. In this paper, span limit is discussed from two perspectives: the theoretical span limit determined by the strength-to-density ratio of the cable and girder, and the engineering span limit, which depends not only on the strength-to-density ratio of materials but also on the actual loading conditions. Closed form equations of both theoretical and engineering span limits of cable-stayed bridges determined by the cable and girder are derived and a detailed parametric analysis is conducted to assess the engineering span limit under current technical conditions. The results show that the engineering span limit of cable-stayed bridges is about 2,200 m based on materials used available today. The girder is the critical member restricting further increase in the span length; its compressive stress is the limiting factor. Approaches to increasing the engineering span limit are also presented based on the analysis results.

Quantitative Evaluation of Fatigue Strength using a Surface defective Low Carbon Steel (저탄소강의 표면결개 방의 영향에 의한 피로강도의 정량적 평가)

  • 윤명진
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.4
    • /
    • pp.42-49
    • /
    • 1995
  • It is not clearly known how defects or inclusions of a low carbon steel affect a fatigue strength. We study this issue using SM15C materials. The investigation is carried out by a quantitative evaluation, and experimental findings are: (1) a fatigue limit of A series smooth specimen is 205MPa, and that of B, C, D series is 245MPa, 304MPa and 245MPa, respectively. (2) the fatigue limit varies with respects to the stress distribution I the vicinity of a defects and crack. (3) the micro hole creates a half-circular shape crack, while the hole depth is not critical to the fatigue strength, (4) considering the fatigue strength, the hole diameter is more significant than the hole depth, and (5) Fatigue limit of artificially defected specimen is lower than that of a flawless one (5-10%), however, there exist allowance size and depth of defect which don't get to influence at fatigue limit.

  • PDF

Study on the Strength Characteristics of PP and ABS According to the Ratio of Recycled Resin (재사용 수지 비율에 따른 PP, ABS의 강도 특성에 관한 연구)

  • Jun-Han Lee;Jong-Sun Kim
    • Design & Manufacturing
    • /
    • v.18 no.2
    • /
    • pp.57-63
    • /
    • 2024
  • In this study, the recyclability of commonly used PP (polypropylene) and ABS (acrylonitrile butadiene styrene) was evaluated by molding test specimens from mixture of virgin and shredded material, followed by measuring their strength properties, Experiments were conducted o two type of PP (transparent and non-transparent) and two types of ABS (white and yellow). Test specimens for each resin were prepared with shredded material ratios ranging from 10% to 50% in 10% increments. Changes in tensile strength, elastic modulus, and elastic limit were analyzed based on the mixing ratio of the shredded material. The experimental results demonstrated that the strength properties of all the resins remained consistent within a certain range, even with increasing proportions of shredded material. For transparent PP, the tensile strength ranged from 30.87± MPa, the elastic modulus from 1.23±0.04 GPa, and the elastic limit from 19.17±0.44%. Non-transparent PP exhibited a tensile strength ranging from 27.71±0.58 MPa, an elastic modulus from 1.03±0.06 GPa, and an elastic limit from 17.35±0.41%. For ABS, white ABS had a tensile strength of 39.42±0.28 MPa, an elastic modulus of 1.94±0.01 GPa, and an elastic limit of 36.76±0.25%. Yellow ABS showed a tensile strength of 39.25±0.78 MPa, an elastic modulus of 1.94±0.01 GPa, and an elastic limit of 37.14±0.23%, with values remaining consistent within this range. Based on these results, it was confirmed that the mechanical properties of the resins used in this study do not change significantly when mixed with recycled shredded material, indicating excellent mechanical recyclability.

Minimum Thickness of Long-Span RC Deck Slabs for 2-girder Bridges Designed by 80 MPa Concrete (80 MPa급 고강도 콘크리트를 활용한 2거더교 RC 장지간 바닥판의 최소두께)

  • Bae, Jae-Hyun;Yoo, Dong-Min;Hwang, Hoon-Hee;Kim, Sung-Tae
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.97-103
    • /
    • 2014
  • To ensure durability and light weight of bridges, high-strength concrete is required for long-span deck slabs. Such a technology eventually extends the life of bridges and improves the economic efficiency. The results of this study suggests a formula for calculating the minimum thickness of long-span deck slabs built with high strength concrete. The minimum thickness is proposed based on the limit states indicated in the CEB-FIP Model Code and the Korean Highway Bridge Design Code(limit state design). The design compressive strength of concrete used for the study is 80MPa. Moreover, the required thickness for satisfying the flexural capacity and limiting deflection is estimated considering the limit state load combination. The formula for minimum thickness of deck slabs is proposed considering the ultimate limit state(ULS) and the serviceability limit state(SLS) of bridges, and by comparing the Korean Highway Bridge Design Code and similar previous studies. According to the research finding, the minimum thickness of long-span deck slab is more influenced by deflection limit than flexural capacity.

Mis-Match Limit Load Analyses and Approximate J-Integral Estimates for Similar Metal Weld with Weld-Center Crack Under Tension Load (용접부 중앙에 표면균열이 존재하는 인장 평판에 대한 강도 불일치 한계하중 해석 및 간략 J-적분 예측)

  • Song, Tae-Kwang;Kim, Yun-Jae;Kim, Jong-Sung;Jin, Tae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.411-418
    • /
    • 2008
  • In this work, the effect of strength mismatch on plastic limit loads is quantified for similar metal weld plates with cracks under tension load, via three-dimensional, small strain elastic-perfectly plastic finite element analyses. Relevant variables related to plate geometry and crack length are systematically varied, in addition to the weld width. An important finding is that mis-match limit loads can be uniquely quantified through strength mis-match ratio and one geometry-related parameter. Based on the proposed limit load solutions, reference stress based J-integral estimates is also investigated. When the reference stress is defined by the mis-match limit load, predicted J-integral values agree overall well with FE results.

Study on the Strength of Limit Axial Force and Accumulated Limit Axial Force of Concrete Filled Square Tube Columns (콘크리트 충전 각형강관 기둥부재의 한계축력 및 누적한계축력에 관한 연구)

  • Seo, Seong Yeon;Jung, Jin Ahn;Kim, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.605-615
    • /
    • 2005
  • Experimental and analytical work was conducted to investigate the relations of axial force and deformational capacity of concrete-filled square steel tube columns. The test series consisting of 36 columns were tested under the constant axial load and horizontal cyclic load. The axial force of the columns that resisted under the cyclic lateral load was defined as a certified strength of limit axial force. The analytical model was defined as a cantilever beam-column. The axial force of the beam-column that resisted under the cyclic lateral load was defined as an accumulated certified strength of limit axial force. The purpose of this study is to investigate the certified strength of limit axial force of concrete-filled steel tube beam-columns, which were subjected to both axial and lateral load condition corresponding to a given constant rotation angle. Another purpose of this study is to discuss the comparison of the certified strength of limit axial force of concrete and the accumulated certified strength of limit axial force of concrete-filled steel tube columns.

Evaluation of Limit Strength for Steel Cable-Stayed Bridgesusing Various Cable Elements (다양한 케이블 요소를 이용한 강사장교의 극한강도 평가)

  • Song, Weon-Keun;Rhee, Jong Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.115-121
    • /
    • 2006
  • This paper deals with the influence of behavior of a variety of cable elements on the limit strength of steel cable-stayed bridges. The softening plastic-hinge model, which is represented in this study for the limit strength evaluation of the example bridge, considers both geometric and material nonlinearites. Geometric nonlinearity of beam-column members are accounted by using stability function, and material nonlinearity - by using CRC tangent modulus and parabolic function. Cable sag effect is considered for cable members. The result of this study shows that the limit strength of the example bridge using the equivalent of elasticity for truss straight elements is smaller than those using the cable or the catenary elements.

The statistical two-order and two-scale method for predicting the mechanics parameters of core-shell particle-filled polymer composites

  • Han, Fei;Cui, Junzhi;Yu, Yan
    • Interaction and multiscale mechanics
    • /
    • v.1 no.2
    • /
    • pp.231-250
    • /
    • 2008
  • The statistical two-order and two-scale method is developed for predicting the mechanics parameters, such as stiffness and strength of core-shell particle-filled polymer composites. The representation and simulation on meso-configuration of random particle-filled polymers are stated. And the major statistical two-order and two-scale analysis formulation is briefly given. The two-order and two-scale expressions for the strains and stresses of conventionally strength experimental components, including the tensional or compressive column, the twist bar and the bending beam, are developed by means of their classical solutions with orthogonal-anisotropic coefficients. Then a new effective mesh generation algorithm is presented. The mechanics parameters of core-shell particle-filled polymer composites, including the expected stiffness parameters, minimum stiffness parameters, and the expected elasticity limit strength and the minimum elasticity limit strength, are defined by means of the stiffness coefficients and elasticity strength criterions for core, shell and matrix. Finally, the numerical results for predicting both stiffness and elasticity limit strength parameters are compared with the experimental data.