Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2022.05a
/
pp.198-201
/
2022
Recently, new cyber threats targeting new technologies are increasing, and hackers' attack targets are becoming broader and more intelligent. To counter these attacks, major security companies are using traditional EDR (Endpoint Detection and Response) solutions. However, the conventional method does not consider the context, so there is a limit to the accuracy and efficiency of responding to an advanced attack. In order to improve this problem, the need for a security solution centered on XDR (Extended Detection and Response) has recently emerged. In this study, we present effective threat detection and countermeasures in a changing environment through XDR trends and development roadmaps using machine learning-based context analysis.
Kim, Jungrae;Sul, Hyewon;Song, Jung-Min;Kim, Geon-Yoon;Kang, Chang-Hee
Analytical Science and Technology
/
v.33
no.1
/
pp.42-48
/
2020
Bromate is a disinfection by-product generated mainly from the oxidation of bromide during the ozonation and disinfection process in order to remove pathogenic microorganism of drinking water, and classified as a possible human carcinogen by International Agency for Research of Cancer (IARC) and World Health Organization (WHO). For the purpose of determining the trace level concentration of bromate, several sensitive techniques are applied mostly based on suppressed conductivity detection and UV/Visible detection after postcolumn reaction (PCR). In this study, the suppressed conductivity detection method and the PCR-UV/Visible detection method through the triiodide reaction were compared to analyze the trace bromate in water samples and estimated for the availability of these analytical methods. In addtion, the state-of-the-art techniques was applied for the determination of trace level bromate in various water matrices, i.e., soft drinking water, hard drinking water, mineral water, swimming pool water, and raw water. In comparison of two analytical methods, it was found that the conductivity detection had the suitable advantage to simultaneously analyze bromate and inorganic anions, however, the bromate might not be precisely quantified due to the matrix effect especially by chloride ion. On the other hand, the trace bromate was analyzed effectively by the method of PCR-UV/Visible detection through triiodide reaction to satisfactorily minimize the matrix interference of chloride ion in various water samples, showing the good linearity and reproducibility. Furthermore, the method detection limit (MDL) and recovery were 0.161 ㎍/L and 101.0-108.1 %, respectively, with a better availability compared to conductivity detection.
Journal of the Institute of Electronics and Information Engineers
/
v.51
no.2
/
pp.23-29
/
2014
The advanced traffic management system of intelligent transport systems automates the related traffic tasks such as vehicle speed, traffic volume and traffic incidents through the improved infrastructures like high definition cameras, high-performance radar sensors. For the safety of road users, especially, the automated incident detection and secondary accident prevention system is required. Normally, CCTV based image object detection and radar based object detection is used in this system. In this paper, we proposed the algorithm for real time highway incident detection system using multi surveillance cameras to mosaic video and track accurately the moving object that taken from different angles by background modeling. We confirmed through experiments that the video detection can supplement the short-range shaded area and the long-range detection limit of radar. In addition, the video detection has better classification features in daytime detection excluding the bad weather condition.
Kim, dong-woo;Song, young-jun;Kim, ae-kyeong;Ahn, jae-hyeong
Proceedings of the Korea Contents Association Conference
/
2009.05a
/
pp.839-842
/
2009
It is used to differential image for moving object detection in general. But it is difficult to detect the accurate detection which uses differential image between frames. In this paper, the proposed method overcome the noise that is generated by camera, grabber card, or weather condition. It extract to moving big object such as human or vehicle. The proposed method process morphological filtering and binary for the image with noise, reduce error. We are expect to apply to a real-time moving object detection system at fog condition, pass the limit of the object detection method using the differential image.
Lee, Seok Chang;Kim, Young Hyun;Kang, Soo Kyung;Park, Myung Hye
Journal of Korea Multimedia Society
/
v.25
no.3
/
pp.546-557
/
2022
Recently, the demand to interpret image data with artificial intelligence in various fields is rapidly increasing. Object recognition and detection techniques using deep learning are mainly used, and video integration analysis to determine unstructured object recognition is a particularly important problem. In the case of natural disasters or social disasters, there is a limit to the object recognition structure alone because it has an unstructured shape. In this paper, we propose intelligent video integration analysis system that can recognize unstructured objects based on video turning point and object detection. We also introduce a method to apply and evaluate object recognition using virtual augmented images from 2D to 3D through GAN.
There were many reports that elevations in the levels of active and latent collagenase in gingival crevicular fluid(GCF) have been correlated positively with periodontal disease activity. To provide a simple diagnostic approach for testing GCF collagenolytic activity, the detection limit of enzyme activity was compared using radiofibril assay(Sodek et.al.1981) and spectrophotometric collagenolytic assay(Nethery et al. 1986). The detection limits of both assay for standard bacterial enzyme were similar and the radiofibril assay showed a little (1/2) lower detection limit for tad pole collagenase. To evaluate the relationship between periodontal tissue destruction and the collagenolytic activity, GCF was collected, and latent and active enzyme activities were measured by a spectrophotometric collagenolytic assay. Twelve subjects showing progressive lesions were selected according to the presence of immediate tissue destruction, frequent abscess formation, and increasing need for tooth extraction, and the absence of underlying systemic disease and previous antibiotic medication history within 6 months. Comparisons were made between sites with either: 1) inflammation with a previous history of progressive loss of periodontal tissue and bone support(2l progressive sites): 2) previous history of bone loss and periodontal destruction but now clinically stable(12 comparably stable sites); or 3) no loss of periodontal tissue and bone support(11 control sites including 5 gingivitis sites and 6 healthy sites). Active collagenase activity was the highest in the progressive sites and decreased in the order of the gingivitis sites, the stable sites, and the healthy sites. The total enzyme activity was $2{\sim}3$ fold higher in the progressive sites and the gingivitis sites, compared to the stable and the healthy sites. The ratio of active to total collagenolytic activity was twice in the progressive sites. Analysis of active collagenase level(5mU) and the ratio of active to total collagenolytic activity(0.8) as a diagnositic test indicates that these measurements have the sensitivity of 0.81 and 0.86, the specificity of 0.70 and 0.65, and the overall agreement of 0.75 and 0.73, respectively. Thus, this method has significant merits as a diagnostic tool to determine wherher the site is in a state of remission or progression.
Hem, Lina;Khay, Sathya;Choi, Jeong-Heui;Morgan, E.D.;El-Aty, A.M. Abd;Shim, Jae-Han
Toxicological Research
/
v.26
no.2
/
pp.149-155
/
2010
The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with ${\mu}$-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dichloromethane was dissolved in ethyl acetate for gas chromatography. Recovery concentration was determined at 0.5, 1.0, and 2.0 of times the maximum permitted residue limits (MRLs) for trichlorfon in milk. The average recoveries (n = 6) ranged from 92.4 to 103.6%. The repeatability of the measurements was expressed as relative standard deviations (RSDs) ranging from 3.6%, to 6.7%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.7 and $11.1{\mu}g/l$, respectively. The accuracy and precision (expressed as RSD) were estimated at concentrations from 25 to $250{\mu}g/l$. The intra- and inter-day accuracy (n = 6) ranged from 89.2% to 91% and 91.3% to 96.3%, respectively. The intra- and inter-day precisions were lower than 8%. The developed method was applied to determine trichlorfon in real samples collected from the seven major cities in the Republic of Korea. No residual trichlorfon was detected in any samples.
Rapid immunochromatography test (RICT) kits are commonly used for the diagnosis of canine parvovirus (CPV) because of their rapid turnaround time, simplicity, and ease of use. However, the potential for cross-reactivity and low sensitivity can yield false-positive or false-negative results. There are 4 genotypes of CPV. Therefore, evaluating the performance and reliability of RICT kits for CPV detection is essential to ensure accurate diagnosis for appropriate treatment. In this study, we evaluated the performance of commercial RICT kits in the diagnosis of all CPV genotypes. The cross-reactivity of 6 commercial RICT kits was evaluated using 8 dog-related viruses and 4 bacterial strains. The limit of detection (LOD) was measured for the 4 genotypes of CPV and feline panleukopenia virus. The tested kits showed no cross-reactivity with the 8 dog-related viruses or 4 bacteria. Most RICT kits showed strong positive results for CPV-2 variants (CPV-2a, CPV-2b, and CPV-2c). However, the 2 kits produced negative results for CPV-2 or CPV-2b at a titer of 105 FAID50/mL, which may result in inaccurate diagnoses. Therefore, some kits need to improve their LOD by increasing their binding efficiency to detect all CPV genotypes.
Journal of Korean Society for Atmospheric Environment
/
v.18
no.1
/
pp.39-49
/
2002
In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.
The HPLC conditions for analysis of ivermectin in solutions dosage forms of commercial anthelmintics are different for each product. The purpose of this study was to establish a standardized chromatographic method for the quantification of ivermectin in solution. The separation was achieved on Waters Xbridge C18 column (4.6×150 nm, 5 ㎛) using different kinds of mobile phase composed of water/methanol/acetonitrile (15/34/51, v/v and 19.5/27.5/53, v/v), with UV detection at wavelengths 245 nm and 254 nm. A total of five commercial ivermectin in solution samples were analyzed. In this study, the optimal chromatographic conditions for analysis of ivermectin in solution were mobile phase of water/methanol/acetonitrile (15/34/51, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 245 nm using a Waters Xbridge C18 column (4.6×250 nm, 5 ㎛) at a column temperature of 25℃. The linearity was observed in the concentration range of 50~150 ㎍/mL, with a correlation coefficient, r2= 0.99999. The limit of detection and the limit of quantification were 0.88 and 2.68 ㎍/mL, respectively. The accuracy (% recovery) was found to be 98.9 to 100.3%. Intra-day and Intermediate precisions with relative standard deviations were less than 1.0%. The content of ivermectin for five market samples ranged 91.2~102.7%. The proposed method was also found to be robust, therefore, the method can be used for the routine analysis of ivermectin in solutions dosage forms.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.