• Title/Summary/Keyword: Limit of Detection

Search Result 2,413, Processing Time 0.037 seconds

The Usefulness of Scintigraphy for the Detection of Gastroesophageal Reflux and Pulmonary Aspiration (위식도 역류와 폐 흡인 진단 방법으로서 위식도 역류 신티그래피의 유용성)

  • Kang, Sung-Kil;Hyun, In-Young;Lim, Dae-Hyun;Kim, Jeong-Hee;Son, Byong-Kwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.12-20
    • /
    • 2008
  • Purpose: Chronic pulmonary disease may be caused by aspiration of gastric contents secondary to gastroesophageal reflux. At present, there is no gold standard for documenting pulmonary aspiration. The purpose of this study was to investigate the usefulness of radionuclide scintigraphy in the detection of gastroesophageal reflux and pulmonary aspiration. Methods: Thirty-five patients with suspected aspiration pneumonia, and five normal control subjects, were included in the study. All subjects underwent gastroesophageal reflux scintigraphy after the ingestion of a $^{99m}Tc$-tin colloid mixture. Dynamic images to detect gastroesophageal reflux were obtained for 1 hour. Additional static images of the chest, to detect lung aspiration, were obtained at 6 and 24 hours after oral ingestion of the tin colloid. In addition to visual analysis, pulmonary aspiration was quantitated by counting the number of pixels labeled with radioactive isotope in the region of interest (ROI) of both lung fields. Aspiration index (AI) was obtained by subtracting the pixel counts of the background from the pixel counts of the ROI. Results: Among 35 patients with suspected aspiration pneumonia, 23 proved to have gastroesophageal reflux by scintigraphy. One patient showed definite pulmonary accumulation of activity by visual analysis of the 6-hour image. Thirty of 35 (85.7%) patients showed higher AI beyond the upper limit of AI in the healthy controls. When we compared the reflux group with the non-reflux group, there was a significantly higher AI at 6 hours in the reflux group (p<0.05). Conclusion: The results suggest that radionuclide scintigraphy is useful in detecting small pulmonary aspiration in patients with suspected aspiration pneumonia secondary to reflux.

  • PDF

Persistence and Distribution of Trunk-Injected Abamectin in Pinus thunbergii and Pinus koraiensis Tissues (수간주입한 아바멕틴의 곰솔과 잣나무 내 분포와 지속성)

  • Lee, Sang-Myeong;Kim, Dong-Soo;Kim, Chul-Su;Cho, Kyu-Seong;Choo, Ho-Yul;Lee, Dong-Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.13 no.3
    • /
    • pp.190-196
    • /
    • 2009
  • The residues of abamectin 1.8% EC, resisted for control of pine wood nematode, Bursaphelenchus xylophilus in pine tree were surveyed in tissue of Pinus thunbergii and P. koraiensis after injection of a liquid formulation. Limits of detection of abamectin in tissue of P. thunbergii were $0.05\;mg\;kg^{-1}$ and mean recoveries at $0.5\;mg\;kg^{-1}$ trunk injection were 90.9% and 93.1% respectively in stem and trunk of P. thunbergii. Abamectin 1.8% EC, trunk injected in 15 m height P. thunbergii were detected in all stem (edible part of carrier insect of pine wood nematode, Monochamus alternatus) from 0.29 to $0.73\;mg\;kg^{-1}$ after 150 days injection. Amount of residue of abamectin 1.8% EC in 12.6 cm mean breast height diameter (DBH) P. thunbergii were variable depending on individual trees in natural forest. Amount of residues in lower and middle part of trunk were reduced with the passage of the injection time. In upper part of trunk were detected $1.84\;mg\;kg^{-1}$ on 30 days after injection however $0.65\;mg\;kg^{-1}$ on 15 days after injection and under detection limit on 100 and 180 days after injection in P. thunbergii. Bottom and middle parts of crown were detected $0.183\;mg\;kg^{-1}$ and $0.173\;mg\;kg^{-1}$ respectively on 180 days after injection in P. thunbergii. Mean residues of abamectin in crown and trunk were $0.80\;mg\;kg^{-1}$ and $0.30\;mg\;kg^{-1}$ on 170 days after trunk injection in 20 cm DBH and 9 m height P. koraiensis. Mean residues of abamectin in crown and trunk were $0.67\;mg\;kg^{-1}$ and $0.36\;mg\;kg^{-1}$ on 170 days after trunk injection in 15 cm DBH and 6 m height P. koraiensis.

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Comparative Analysis of Pesticide Residues in Agricultural Products in Circulation in Gyeonggi-do Before and After Positive List System Enforcement (PLS 시행 전후 경기도 유통 농산물의 잔류농약 실태 비교 분석)

  • Song, Seo-Hyeon;Kim, Ki-Yu;Kim, Yun-Sung;Ryu, Kyong-Shin;Kang, Min-Seong;Lim, Jeong-Hwa;Yoo, Na-Young;Han, Yoo-Li;Choi, Hee-Jeong;Kang, Choong-Won;Kim, Youn-Ho;Seo, Jeong-Hwa;Choi, Ok-Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.239-247
    • /
    • 2021
  • In order to confirm the impact of the Positive List System (PLS) being applied to all agricultural products from January 1, 2019, we analyzed 28,693 points of inspection-related data on agricultural products distributed in Gyeonggi-do from 2018 to 2020. The ratio of cases exceeding the standard for the total inspection performance was 1.0% in 2018, 1.2% in 2019, and 1.2% in 2020. Out of the 114 cases exceeding the standard in 2019, 55 were applied on a Maximum Residue Limit (MRL) of 0.01 mg/kg, and out of the 115 cases exceeding the standard in 2020, 66 were applied on a MRL of 0.01 mg/kg. To improve this, it seems necessary to manage unintentional pollution, conventional use for unregistered crops, and illegal pesticides. Fluquinconazole detection resulted from unintentional contamination, and diazinon, chlorothalonil, and methabenzthiazuron detection resulted from conventional use in unregistered crops. Chinomethionat is a pesticide component that was discarded in the past and its current use has been attributed to the smuggling of pesticides. This study and future monitoring data can be used as reference data for system supplementation and on-site management reinforcement.

Establishment of Test Conditions and Interlaboratory Comparison Study of Neuro-2a Assay for Saxitoxin Detection (Saxitoxin 검출을 위한 Neuro-2a 시험법 조건 확립 및 실험실 간 변동성 비교 연구)

  • Youngjin Kim;Jooree Seo;Jun Kim;Jeong-In Park;Jong Hee Kim;Hyun Park;Young-Seok Han;Youn-Jung Kim
    • Journal of Marine Life Science
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2024
  • Paralytic shellfish poisoning (PSP) including Saxitoxin (STX) is caused by harmful algae, and poisoning occurs when the contaminated seafood is consumed. The mouse bioassay (MBA), a standard test method for detecting PSP, is being sanctioned in many countries due to its low detection limit and the animal concerns. An alternative to the MBA is the Neuro-2a cell-based assay. This study aimed to establish various test conditions for Neuro-2a assay, including cell density, culture conditions, and STX treatment conditions, to suit the domestic laboratory environment. As a result, the initial cell density was set to 40,000 cells/well and the incubation time to 24 hours. Additionally, the concentration of Ouabain and Veratridine (O/V) was set to 500/50 μM, at which most cells died. In this study, we identified eight concentrations of STX, ranging from 368 to 47,056 fg/μl, which produced an S-shaped dose-response curve when treated with O/V. Through inter-laboratory variability comparison of the Neuro-2a assay, we established five Quality Control Criteria to verify the appropriateness of the experiments and six Data Criteria (Top and Bottom OD, EC50, EC20, Hill slop, and R2 of graph) to determine the reliability of the experimental data. The Neuro-2a assay conducted under the established conditions showed an EC50 value of approximately 1,800~3,500 fg/μl. The intra- & inter-lab variability comparison results showed that the coefficients of variation (CVs) for the Quality Control and Data values ranged from 1.98% to 29.15%, confirming the reproducibility of the experiments. This study presented Quality Control Criteria and Data Criteria to assess the appropriateness of the experiments and confirmed the excellent repeatability and reproducibility of the Neuro-2a assay. To apply the Neuro-2a assay as an alternative method for detecting PSP in domestic seafood, it is essential to establish a toxin extraction method from seafood and toxin quantification methods, and perform correlation analysis with MBA and instrumental analysis methods.

Evaluation for Application of IOM Sampler for Agricultural Farmer's Inhalation Exposure to Kresoxim-methyl and Fenthion (농작업자의 Kresoxim-methyl과 fenthion에 대한 호흡노출량 측정을 위한 IOM 채집기의 효율성 평가)

  • Lee, Jiho;Kim, Eunhye;Lee, Jonghwa;Shin, Yongho;Maasfeld, Wolfgang;Choi, Hoon;Moon, Joon-Kwan;Lee, Hyeri;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.230-240
    • /
    • 2015
  • An IOM sampler equipped with glass fiber filter has been recently utilized instead of solid adsorbent, which was used to measure the inhalation exposure of agricultural operator to pesticides. The aim of this study is to validate the efficacy of an IOM sampler by measuring the trapping efficiency and breakthrough using kresoxim-methyl water-dispersible granule and fenthion emulsifiable concentrate. On LC-MS/ MS, minimum detection level was 12.5 pg and method limit of detection was 5.0 ng/mL. Good linearity ($R^2$ > 0.999) for matrix matched standards was obtained. Recoveries of pesticides from glass fiber filter were 102-109% (kresoxim-methyl) and 97-104% (fenthion) while those from XAD-2 resin were 94-98% (kresoxim methyl) and 93-100% (fenthion). Trapping efficiency test was performed with personal air pumps and IOM sampler (glass fiber filter) connected with solid adsorbent (XAD-2 resin) with two types of formulation (solid and liquid) which were diluted by standard rate and sprayed to IOM sampler. Those pesticides were trapped only in glass fiber filter without any breakthrough to solid adsorbent. After spiking of pesticides to glass fiber filter, breakthrough test was carried out with IOM sampler (glass fiber filter) which was connected with solid adsorbent. As a results, 87-101% of kresoxim-methyl and 96-105% of fenthion remained in spiked glass fiber filter, however, no pesticides were detected in second glass fiber filter and solid adsorbent. In conclusion, IOM sampler which equipped with glass fiber filter can be applied widely for pesticide inhalation exposure study since it has good trapping efficiency and adsorption capacity, regardless of the solid or liquid formulation.

Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant (하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성)

  • Kim, Yong-Jun;Chung, David;Jeong, Mi-Jeong;Yoo, Hye-Young;Yoon, Cheol-Woo;Shin, Sun-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.23-33
    • /
    • 2016
  • The characteristics of ammonia generated from alkaline stabilization facilities was investigated which are for organic sewage sludge from wastewater treatment plants. The highest concentration of ammonia was found in mixing and curing process in alkaline stabilization facility and ammonia mainly showed a range of 87.78 ppm($66.62mg/m^3$) to 1,933 ppm($1,467.01mg/m^3$) by detection tube. This is presumed to occur because nitrogen oxides are converted into ammonia as the sewage sludge is mixed with lime. In some facilities, hydrogen sulfide and methyl mercaptan were detected in relatively high concentrations, but odor materials except ammonia were not detected in most of the facilities. The concentration of ammonia caused by process was generally high in the order of "mixing > curing > output > storage > drying > input." It was found that odor compounds are removed by wet absorption using sulfuric acid and sodium hypochlorite in the 5 alkaline stabilization facilities currently in operation. Each facility was designed to meet the concentration of after-treatment emission in 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) or 100 ppm($75.89mg/m^3$), but no facility satisfied the design standard for their emssion limit. In case of ammonia, some workplaces in alkaline stabilization facilities exceeded the exposure limits established by the Ministry of Labor. It appears that proper ventilation should be provided for the safety of workers in future. No odor compound including ammonia was found by detection tubes in the border of the facilities, but trace amounts of odor compounds are expected to exist, given the current operational status of facilities.

Development of Multi-residue Analysis and Monitoring of Persistent Organic Pollutants (POPs) - Used Organochlorine Pesticides in Korea (국내에 사용되어 금지된 유기염소계 농약류의 다중분석법과 모니터링)

  • Lim, Sung-Jin;Oh, Young-Tak;Yang, Ji-Yeon;Ro, Jin-Ho;Choi, Geun-Hyoung;Ryu, Song-Hee;Moon, Byeong-Chul;Park, Byung-Jun
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.4
    • /
    • pp.319-325
    • /
    • 2016
  • This study was conducted to investigate residual organochlorine pesticides in green house soil and oriental melon, green pepper, and lettuce. The majority of them were designated as persistent organic pollutants (POPs) by the international community at the Stockholm Convention on Persistent Organic Pollutant. Extraction and clean-up method were developed using the QuEChERS method for residual organochlorine pesticides (OCPs) in soil and oriental melon, green pepper and lettuce. Recovery of OCPs in greenhouse soil and oriental melon, green pepper, and lettuce ranged from 73.3-110.6%. Limit of detection (LOD) of OCPs in soil and 3 crops were 0.01-0.08 and $0.11-0.17{\mu}g/kg$. The residues of OCPs in oriental melon, green pepper and lettuce greenhouse soil were analyzed by the developed method, and dieldrin, ${\beta}-endosulfan$ and endosulfan sulfate were detected at 1.4-72.5, 0.1-78.7 and $0.0-214.1{\mu}g/kg$, respectively. The detection frequency of 3 compounds in soils were 52 (29.7%), 34 (19.4%) and 57 (32.6%) among 175 samples, respectively. However, these compounds were not detected in all crop samples. The residue level in 3 crops were lower than 1/58.8 of maximum residue level of them. These results showed that the OCPs residue in oriental melon, green pepper, and lettuce greenhouse soil were not as high as crop safety threatening.

Determination of Aflatoxins in Nuts, Their Products and Dried Fruits Using Rapid Resolution Liquid Chromatography Coupled with Tandem Mass Spectrometry (RRLC-MS/MS를 이용한 견과류 및 그 가공품과 건조과실류의 아플라톡신 분석)

  • Choi, Su-Jeong;Park, Ju-Sung;Jung, So-Young;Son, Yeo-Joon;Lyi, Yun-Jeong;Kim, Mi-Sun;Park, So-Hyun;Lee, Sang-Me;Chae, Young-Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.702-710
    • /
    • 2011
  • The occurrence of aflatoxins $B_1$, $B_2$, $G_1$ and $G_2$ in nuts, their products and dried fruits was investigated. Samples were collected from local markets in Seoul and analyzed by rapid resolution liquid chromatography coupled with tandem mass spectrometry using an immunoaffinity column. The chromatography method was validated for assay of aflatoxins using linearity, accuracy, precision and limit of detection and quantification. The linearity in the concentration ranged from 0.10 to $20{\mu}g/kg$ with $R^2$ > 0.9999. Sample recoveries ranged from 71.1 to 97.2% with relative standard deviations below 4.5% for spiking levels from 1 to $10{\mu}g/kg$. The limits of detection ranged between 0.02 and $0.05{\mu}g/kg$ and the limits of quantification ranged between 0.05 and $0.10{\mu}g/kg$. The levels of aflatoxin $B_1$, $B_2$, $G_1$ and $G_2$ in nuts, their products and dried fruits were $B_1$ 0.10 to $9.94{\mu}g/kg$, $B_2$ 0.08 to $1.54{\mu}g/kg$, $G_1$ 0.04 to $3.21{\mu}g/kg$ and $G_2$ 0.06 to $0.14{\mu}g/kg$.

Evaluation of Applicability of Sea Ice Monitoring Using Random Forest Model Based on GOCI-II Images: A Study of Liaodong Bay 2021-2022 (GOCI-II 영상 기반 Random Forest 모델을 이용한 해빙 모니터링 적용 가능성 평가: 2021-2022년 랴오둥만을 대상으로)

  • Jinyeong Kim;Soyeong Jang;Jaeyeop Kwon;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1651-1669
    • /
    • 2023
  • Sea ice currently covers approximately 7% of the world's ocean area, primarily concentrated in polar and high-altitude regions, subject to seasonal and annual variations. It is very important to analyze the area and type classification of sea ice through time series monitoring because sea ice is formed in various types on a large spatial scale, and oil and gas exploration and other marine activities are rapidly increasing. Currently, research on the type and area of sea ice is being conducted based on high-resolution satellite images and field measurement data, but there is a limit to sea ice monitoring by acquiring field measurement data. High-resolution optical satellite images can visually detect and identify types of sea ice in a wide range and can compensate for gaps in sea ice monitoring using Geostationary Ocean Color Imager-II (GOCI-II), an ocean satellite with short time resolution. This study tried to find out the possibility of utilizing sea ice monitoring by training a rule-based machine learning model based on learning data produced using high-resolution optical satellite images and performing detection on GOCI-II images. Learning materials were extracted from Liaodong Bay in the Bohai Sea from 2021 to 2022, and a Random Forest (RF) model using GOCI-II was constructed to compare qualitative and quantitative with sea ice areas obtained from existing normalized difference snow index (NDSI) based and high-resolution satellite images. Unlike NDSI index-based results, which underestimated the sea ice area, this study detected relatively detailed sea ice areas and confirmed that sea ice can be classified by type, enabling sea ice monitoring. If the accuracy of the detection model is improved through the construction of continuous learning materials and influencing factors on sea ice formation in the future, it is expected that it can be used in the field of sea ice monitoring in high-altitude ocean areas.